High frequency ultrasound tissue characterization and acoustic microscopy of intracellular changes

被引:40
|
作者
Brand, Sebastian [1 ,2 ,5 ]
Weiss, Eike C. [3 ]
Lemor, Robert M. [3 ]
Kolios, Michael C. [1 ,2 ,4 ]
机构
[1] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[2] Princess Margaret Hosp, Ontario Canc Inst, Toronto, ON M4X 1K9, Canada
[3] Fraunhofer Inst Biomed Tech, St Ingbert, Germany
[4] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[5] Univ Halle Wittenberg, Dept Orthopaed, Q BAM Lab, D-06112 Halle, Germany
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 2008年 / 34卷 / 09期
基金
加拿大自然科学与工程研究理事会;
关键词
high frequency ultrasound; acoustic microscopy; viable cells; quantitative ultrasound;
D O I
10.1016/j.ultrasmedbio.2008.01.017
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective of this work is to investigate changes in the acoustic properties of cells when exposed to chemotherapy for monitoring treatment response. High frequency ultrasound spectroscopy (10-60 MHz) and scanning acoustic microscopy (0.9 GHz) were performed on HeLa cells (Ackermann et al. 1954, Masters 2002) that were exposed to the chemotherapeutic agent cisplatin. Ultrasonic radio-frequency data were acquired from pellets containing HeLa cells after exposure to cisplatin to induce apoptosis. Scanning acoustic and laser fluorescence microscopy images were recorded from single HeLa cells exposed to the same drug. Data acquisition in both cases was performed at several time points throughout the chemotherapeutic treatment for up to 27 h. In the high frequency ultrasound investigation, normalized power spectra were calculated within a region-of-interest. A 20 MHz transducer (f-number 2.35) and a 40 MHz transducer (f-number 3) were used for the data collection in the high frequency ultrasound experiments. The backscatter coefficients, integrated backscatter coefficients, mid-band fit and spectral slope were computed as a function of treatment time to monitor acoustical property changes during apoptosis. Acoustic attenuation was measured using the spectral substitution technique at all time points. Spectral parameter changes were detected after 12 h of exposure and coincided with the initiation of cell damage as assessed by optical microscopy. Integrated backscatter coefficients increased by over 100% between 0 h and 24 h of treatment, with small changes in the associated attenuation (similar to 0.1 dB/[MHz cm]). Acoustic microscopy was performed at 0.9 GHz frequency. The cell structure was imaged using staining in laser fluorescence microscopy. All cells showed excellent correspondence between the locations of apoptotic nuclear condensation observed in optical imaging and changes in attenuation contrast in acoustic microscopy images. The time after drug exposure at which such changes occurred in the optical images were coincident with the time of changes detected in the acoustic microscopy images and the high frequency ultrasound experiments.
引用
收藏
页码:1396 / 1407
页数:12
相关论文
共 50 条
  • [1] High frequency ultrasound tissue characterization
    Fox, MD
    Pruehsner, WR
    PROCEEDINGS OF THE IEEE 23RD NORTHEAST BIOENGINEERING CONFERENCE, 1997, : 44 - 45
  • [2] TISSUE CHARACTERIZATION BY LOW-FREQUENCY ACOUSTIC WAVES GENERATED BY A SINGLE HIGH-FREQUENCY FOCUSED ULTRASOUND BEAM
    Braz, Guilherme A.
    Baggio, Andre L.
    Agnollitto, Paulo M.
    Grillo, Felipe W.
    Pavan, Theo Z.
    Paula, Francisco J. A.
    Nogueira-Barbosa, Marcello H.
    Cardoso, George C.
    Carneiro, Antonio A. O.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (02): : 334 - 344
  • [3] Visualization of apoptotic cells using scanning acoustic microscopy and high frequency ultrasound
    Brand, S
    Czarnota, GJ
    Kolios, MC
    Weiss, EC
    Lemor, R
    2005 IEEE Ultrasonics Symposium, Vols 1-4, 2005, : 882 - 885
  • [4] High frequency ultrasound image and tissue characterization for human thyroid
    2001, China Society of Biomedical Engineering (20):
  • [5] High resolution acoustic metrology by combining high GHZ frequency ultrasound and scanning probe microscopy
    van Es, Maarten H.
    Quesson, Benoit A., I
    Mohtashami, Abbas
    Piras, Daniele
    Hatakeyama, Kodai
    Fillinger, Laurent
    van Neer, Paul L. M. J.
    METROLOGY, INSPECTION, AND PROCESS CONTROL FOR MICROLITHOGRAPHY XXXIV, 2020, 11325
  • [6] THE USE OF ACOUSTIC MICROSCOPY FOR BIOLOGICAL TISSUE CHARACTERIZATION
    KOLOSOV, OV
    LEVIN, VM
    MAYEV, RG
    SENJUSHKINA, TA
    ULTRASOUND IN MEDICINE AND BIOLOGY, 1987, 13 (08): : 477 - 483
  • [7] Acoustic impedance microscopy for biological tissue characterization
    Kobayashi, Kazuto
    Yoshida, Sachiko
    Saijo, Yoshifumi
    Hozumi, Naohiro
    ULTRASONICS, 2014, 54 (07) : 1922 - 1928
  • [8] TISSUE CHARACTERIZATION USING SCANNING ACOUSTIC MICROSCOPY
    SINCLAIR, DA
    SMITH, IR
    ASH, EA
    ULTRASONIC IMAGING, 1981, 3 (02) : 212 - 212
  • [9] High-frequency ultrasound for monitoring changes in liver tissue during preservation
    Vlad, RM
    Czarnota, GJ
    Giles, A
    Sherar, MD
    Hunt, JW
    Kolios, MC
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (02): : 197 - 213
  • [10] Direct and sustained intracellular delivery of exogenous molecules using acoustic-transfection with high frequency ultrasound
    Yoon, Sangpil
    Kim, Min Gon
    Chiu, Chi Tat
    Hwang, Jae Youn
    Kim, Hyung Ham
    Wang, Yingxiao
    Shung, K. Kirk
    SCIENTIFIC REPORTS, 2016, 6