Early biomechanical keratoconus pattern measured with an ocular response analyzer: Curve analysis

被引:44
|
作者
Touboul, David [1 ]
Benard, Antoine
Mahmoud, Ashraf M.
Gallois, Anne [1 ]
Colin, Joseph [1 ]
Roberts, Cynthia J. [2 ]
机构
[1] Univ Bordeaux 2, Dept Ophthalmol, F-33076 Bordeaux, France
[2] Ohio State Univ, Dept Biomed Engn, Columbus, OH 43210 USA
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2011年 / 37卷 / 12期
关键词
IN-SITU KERATOMILEUSIS; INTRAOCULAR-PRESSURE; CORNEAL THICKNESS; HYSTERESIS; ELASTICITY;
D O I
10.1016/j.jcrs.2011.06.029
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To estimate the ability of the Ocular Response Analyzer parameters to aid in the diagnosis of keratoconus in pre-laser in situ keratomileusis (LASIK) patients. SETTING: Department of Ophthalmology, Bordeaux 2 University, Bordeaux Cedex, France. DESIGN: Evaluation of diagnostic test. METHODS: This study compared eyes with mild stages of keratoconus (study group) with preoperative eyes that later had LASIK (control group). Corneas with a central thickness within 500 to 600 mu m were targeted. The biomechanical measurements were acquired, and 12 parameters were analyzed after extraction from the signal data. RESULTS: The study group comprised 103 eyes and the control group, 97 eyes. The mean corneal hysteresis (CH) was 9.2 mm Hg in study eyes and 10.1 mm Hg in control eyes and the mean corneal resistance factor (CRF), 8.9 mm Hg and 10.6 mm Hg, respectively. For a threshold of 9.6, CH had a sensitivity of 66% with a specificity of 67%. For a threshold of 9.7, the CRF had a sensitivity of 72% and a specificity of 77%. For 6 biomechanical parameters, the probability that a patient would present with keratoconus was 3 in 1000 if 1 parameter was over the chosen threshold. CONCLUSIONS: If 1 of 6 parameters were over a chosen threshold, the probability that a patient would present with keratoconus would be almost 3 in 1000 instead of 9 in 1000 in a LASIK surgery cohort. Despite low sensitivity and specificity, some parameters provided by the corneal analyzer offered high negative likelihood ratios and deserve more study with bigger samples.
引用
收藏
页码:2144 / 2150
页数:7
相关论文
共 50 条
  • [1] Keratoconus cone location influences ocular biomechanical parameters measured by the Ocular Response Analyzer
    Yuhas, Phillip T.
    Fortman, Maddison M.
    Mahmoud, Ashraf M.
    Roberts, Cynthia J.
    EYE AND VISION, 2024, 11 (01)
  • [2] Keratoconus cone location influences ocular biomechanical parameters measured by the Ocular Response Analyzer
    Phillip T. Yuhas
    Maddison M. Fortman
    Ashraf M. Mahmoud
    Cynthia J. Roberts
    Eye and Vision, 11
  • [3] Multivariate Analysis of the Ocular Response Analyzer's Corneal Deformation Response Curve for Early Keratoconus Detection
    Galletti, Jonatan D.
    Ruisenor Vazquez, Pablo R.
    Fuentes Bonthoux, Fernando
    Pfoertner, Tomas
    Galletti, Jeremias G.
    JOURNAL OF OPHTHALMOLOGY, 2015, 2015
  • [4] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Sen, Emine
    Tutuncu, Yasemin
    Balikoglu-Yilmaz, Melike
    Elgin, Ufuk
    Berker, Dilek
    Ozturk, Faruk
    Guler, Serdar
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (08) : 1283 - 1288
  • [5] Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes
    Kotecha, Aachal
    Russell, Richard A.
    Sinapis, Angelos
    Pourjavan, Sayeh
    Sinapis, Dimitros
    Garway-Heath, David F.
    BMC OPHTHALMOLOGY, 2014, 14
  • [6] Biomechanical parameters of the cornea measured with the Ocular Response Analyzer in normal eyes
    Aachal Kotecha
    Richard A Russell
    Angelos Sinapis
    Sayeh Pourjavan
    Dimitros Sinapis
    David F Garway-Heath
    BMC Ophthalmology, 14
  • [7] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Emine Sen
    Yasemin Tutuncu
    Melike Balikoglu-Yilmaz
    Ufuk Elgin
    Dilek Berker
    Faruk Ozturk
    Serdar Guler
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1283 - 1288
  • [8] Evaluation of Corneal Biomechanical Properties Measured by Ocular Response Analyzer in Eyes with Pterygium
    Kara, Necip
    Baz, Okkes
    Bozkurt, Ercument
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    Yilmaz, Omer Faruk
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (02): : 94 - 97
  • [9] Evaluation of Corneal Biomechanical Properties Measured By Ocular Response Analyzer in Cases with Rheumatoid Arthritis
    Altinkaynak, Hasan
    Kara, Necip
    Baz, Okkes
    Celik, Yonca Cagatay
    Bozkurt, Ercument
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (03): : 167 - 170
  • [10] Evaluation of Corneal Biomechanical Changes After Collagen Crosslinking in Patients with Progressive Keratoconus by Ocular Response Analyzer
    Kucumen, Raciha Beril
    Sahan, Berna
    Yildirim, Canan Asli
    Ciftci, Ferda
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (04): : 160 - 165