Evaluation of Corneal Biomechanical Properties Measured By Ocular Response Analyzer in Cases with Rheumatoid Arthritis

被引:0
|
作者
Altinkaynak, Hasan [1 ]
Kara, Necip [1 ]
Baz, Okkes [1 ]
Celik, Yonca Cagatay [2 ]
Bozkurt, Ercument [1 ]
Yazici, Ahmet Taylan [1 ]
Demirok, Ahmet [1 ]
机构
[1] Beyoglu Goz Egitim & Arasbrma Hastanesi, Istanbul, Turkey
[2] Haseki Egitim & Arasorma Hastanesi, Dahiliye Klin, Istanbul, Turkey
关键词
Rheumatoid arthritis; Ocular response analyzer; Corneal hysteresis;
D O I
10.4274/tjo.41.09797
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the corneal biomechanical properties using an ocular response analyzer (ORA) in patients with rheumatoid arthritis and healthy control subjects. Material and Method: Thirty four eyes of 17 healthy individuals (control group) and 34 eyes of 17 patients with RA (study group) were recruited. ORA measurements were performed in all patients. Corneal-compensated intraocular pressure (IOPcc), Goldman related intraocular pressure (IOPg), corneal resistance factor (CRF), and corneal hysteresis (CH) were recorded. Statistical analyses were performed using a t test for independent samples. Results: In the study group, mean CH was 11.5 +/- 2.1 (7.7-16.2) mmHg, mean CRF was 12.1 +/- 2.3 (8.2-17) mmHg, IOPg 17.2 +/- 4.4 (8.3-25.1) and mean IOPcc was 16.5 +/- 4.3 (7.7-24.2) mmHg. In the control group, mean CH was 11.6 +/- 1.1 (9.7-13.8) mmHg, mean CRF was (11.8 +/- 1.2 (9.8-14.1) mmHg, IOPg 15.9 +/- 3.3 (9.4-25.7), and mean IOPcc was 15.4 +/- 2.6 (8.8-21.2) mmHg. There were no significant differences in these parameters between the study and control groups (p>0.05). Discussion: The biomechanical parameters measured with ORA were not statistical difference in patients with rheumatoid arthritis and age matched healthy individuals. (Turk J Ophthalmol 2011; 41: 167-70)
引用
收藏
页码:167 / 170
页数:4
相关论文
共 50 条
  • [1] Evaluation of Corneal Biomechanical Properties in Patients with Rheumatoid Arthritis: A Study by Ocular Response Analyzer
    Tas, Mehmet
    Oner, Veysi
    Ozkaya, Erdal
    Durmus, Mustafa
    [J]. OCULAR IMMUNOLOGY AND INFLAMMATION, 2014, 22 (03) : 224 - 227
  • [2] Evaluation of Corneal Biomechanical Properties Measured by Ocular Response Analyzer in Eyes with Pterygium
    Kara, Necip
    Baz, Okkes
    Bozkurt, Ercument
    Yazici, Ahmet Taylan
    Demirok, Ahmet
    Yilmaz, Omer Faruk
    [J]. TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2011, 41 (02): : 94 - 97
  • [3] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Sen, Emine
    Tutuncu, Yasemin
    Balikoglu-Yilmaz, Melike
    Elgin, Ufuk
    Berker, Dilek
    Ozturk, Faruk
    Guler, Serdar
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (08) : 1283 - 1288
  • [4] Corneal biomechanical properties measured by the ocular response analyzer in acromegalic patients
    Emine Sen
    Yasemin Tutuncu
    Melike Balikoglu-Yilmaz
    Ufuk Elgin
    Dilek Berker
    Faruk Ozturk
    Serdar Guler
    [J]. Graefe's Archive for Clinical and Experimental Ophthalmology, 2014, 252 : 1283 - 1288
  • [5] Evaluation of corneal biomechanical properties with the Reichert Ocular Response Analyzer
    Detry-Morel, Michele
    Jamart, Jacques
    Pourjavan, Saveh
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2011, 21 (02) : 138 - 148
  • [6] Correlations between corneal biomechanical properties measured with the Ocular Response Analyzer and ICare rebound tonometry
    Martins Jorge, Jorge Manuel
    Gonzalez-Meijome, Jose M.
    Queiros, Antonio
    Fernandes, Paulo
    Parafita, Manuel A.
    [J]. JOURNAL OF GLAUCOMA, 2008, 17 (06) : 442 - 448
  • [7] Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer
    Murugesan, Vanathi
    Bypareddy, Ravi
    Kumar, Mahesh
    Tanuj, Dada
    Anita, Panda
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (04) : 454 - 460
  • [8] Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    Kotecha, Aachal
    Elsheikh, Ahmed
    Roberts, Cynthia R.
    Zhu, Haogang
    Garway-Heath, David F.
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (12) : 5337 - 5347
  • [9] Biomechanical properties of the cornea measured by the Ocular Response Analyzer and their association with intraocular pressure and the central corneal curvature
    Franco, Sandra
    Lira, Madalena
    [J]. CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (06) : 469 - 475
  • [10] Corneal thickness- and age-related biomechanical properties of the cornea measured with the ocular response analyzer
    Oddone, F
    Kotecha, A
    Shewry, J
    White, ET
    Garway-Heath, DF
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46