Magnetically levitated motor for rotary blood pumps

被引:13
|
作者
Okada, Y
Ueno, S
Ohishi, T
Yamane, T
Tan, CC
机构
[1] SHINKO ELECT CO LTD,ISE,JAPAN
[2] MECH ENGN LAB,TSUKUBA,IBARAKI 305,JAPAN
[3] QUEENSLAND UNIV TECHNOL,BRISBANE,QLD,AUSTRALIA
关键词
noncontact rotary pump; levitated motor; radial magnetic bearing; axial magnetic bearing; digital control;
D O I
10.1111/j.1525-1594.1997.tb03733.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The noncontact rotary pumps under development for use as artificial heart pumps are highly efficient and can prevent thrombus formation. In these pumps magnetic bearings have been widely used to support the rotors to avoid any physical contact. The use of magnetic bearings, however, has led to requirements for the control of a large degree of freedom and for a separate driving motor. This paper introduces 2 types of levitated motors, each of which uses a combination of a rotary motor and a magnetic bearing. These motors are suitable for use in artificial blood pumps because they are small in size and can replace contact components. The radial type levitated motor has the merit of being small in size and capable of controlling the 2 degrees of freedom in the x and y directions. The axial type motor controls only one degree of freedom in the z direction. This paper also introduces the theoretical background of the functions of the motor and magnetic bearing. Experimental results of tests of the proposed motor show a great potential for its application in rotary blood pumps.
引用
收藏
页码:739 / 745
页数:7
相关论文
共 50 条
  • [21] Active Deformation Control for a Magnetically Levitated Planar Motor Mover
    Proimadis, Ioannis
    Custers, Coen H. H. M.
    Toth, Roland
    Jansen, J. W.
    Butler, Hans
    Lomonova, Elena
    Van den Hof, Paul M. J.
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (01) : 242 - 249
  • [22] Study on a Double Stator Type Axial Magnetically Levitated Motor
    Kurita, Nobuyuki
    Ishikawa, Takeo
    [J]. 2013 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2013,
  • [23] Development of Linear Switched Reluctance Motor for Magnetically Levitated System
    Kakinoki, Toshio
    Yamaguchi, Hitoshi
    Murakami, Tomoaki
    Mukai, Eiichi
    Nishi, Hiroyuki
    [J]. 2016 19TH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS (ICEMS 2016), 2016,
  • [24] Measurement for implantable rotary blood pumps
    Bertram, CD
    [J]. PHYSIOLOGICAL MEASUREMENT, 2005, 26 (04) : R99 - R117
  • [25] Condition monitoring of rotary blood pumps
    Jammu, VB
    Malanoski, S
    Walter, T
    Smith, W
    [J]. ASAIO JOURNAL, 1997, 43 (05) : M639 - M643
  • [26] Control strategy for rotary blood pumps
    Ohuchi, K
    Kikugawa, D
    Takahashi, K
    Uemura, M
    Nakamura, M
    Murakami, T
    Sakamoto, T
    Takatani, S
    [J]. ARTIFICIAL ORGANS, 2001, 25 (05) : 366 - 370
  • [27] Multiobjective Optimization of a Magnetically Levitated Planar Motor With Multilayer Windings
    Guo, Liang
    Zhang, He
    Galea, Michael
    Li, Jing
    Gerada, Chris
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (06) : 3522 - 3532
  • [28] Guest Editorial: Special Issue on Magnetically Levitated Motor Systems
    Severson, Eric
    Chiba, Akira
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2021, 57 (06) : 6742 - 6743
  • [29] Rotary blood pumps: A new horizon
    Olsen, DB
    [J]. ARTIFICIAL ORGANS, 1999, 23 (08) : 695 - 696
  • [30] Purge system for rotary blood pumps
    Sipin, AJ
    Bender, B
    Fabrey, WJ
    Keller, R
    Liu, J
    Olsen, DB
    [J]. ARTIFICIAL ORGANS, 1997, 21 (07) : 611 - 619