Refining a region-of-interest within an available CT image

被引:2
|
作者
Enjilela, Esmaeil [1 ]
Hussein, Esam M. A. [1 ]
机构
[1] Univ New Brunswick, Dept Mech Engn, Lab Threat Mat Detect, Fredericton, NB E3B 5A3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Computed tomography; Region-of-interest; Image enhancement; Subtraction techniques; Reconstruction algorithms; ITERATIVE RECONSTRUCTION; TOMOGRAPHY; QUALITY;
D O I
10.1016/j.apradiso.2013.02.004
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This paper describes a numerical method for refining the image of a region-of-interest (RoI) within an existing tomographic slice, provided that projection data are stored along with the image. Using the attributes of the image, projection values (ray-sums) are adjusted to compensate for the material outside the RoI. Advantage is taken of the high degree of overdetermination of common computed tomography systems to reconstruct an RoI image over smaller pixels. The smaller size of a region-of-interest enables the use of iterative methods for RoI image reconstruction, which are less prone to error propagation. Simulation results are shown for an anthropomorphic head phantom, demonstrating that the introduced approach enhances both the spatial resolution and material contrast of RoI images; without the need to acquire any additional measurements or to alter existing imaging setups and systems. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:77 / 84
页数:8
相关论文
共 50 条
  • [41] A relative quality controled region-of-interest image coding based on wavelet transform
    Fukuma, S
    Ito, M
    Imajo, C
    Nishimura, S
    Nawate, M
    [J]. 2002 45TH MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL I, CONFERENCE PROCEEDINGS, 2002, : 459 - 462
  • [42] The Effect of Region-Of-Interest Z-Axis Collimation on the Image Quality of a Commercial Cone Beam CT Imaging System
    Goodsitt, M.
    Larson, S.
    Christodoulou, E.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [43] Region-of-interest microtomography for component inspection
    Kalukin, AR
    Keane, DT
    Roberge, WG
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1999, 46 (01) : 36 - 41
  • [44] ANALYSIS AND IMPROVEMENT IN REGION-OF-INTEREST TOMOGRAPHY
    OHYAMA, N
    SHIRAISHI, A
    HONDA, T
    TSUJIUCHI, J
    [J]. APPLIED OPTICS, 1984, 23 (22): : 4105 - 4110
  • [45] Preliminary study of region-of-interest image reconstruction with intensity weighting in cone-beam CT using iterative algorithm
    Son, Kihong
    Lee, Jiseoc
    Lee, Younjeong
    Kim, Jin Sung
    Cho, Seungryong
    [J]. MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [46] Is Lip Region-of-Interest Suficient for Lipreading?
    Zhang, Jing-Xuan
    Wan, Gen-Shun
    Pan, Jia
    [J]. PROCEEDINGS OF THE 2022 INTERNATIONAL CONFERENCE ON MULTIMODAL INTERACTION, ICMI 2022, 2022, : 368 - 372
  • [47] ANALYSIS AND IMPROVEMENT IN REGION-OF-INTEREST TOMOGRAPHY
    OHYAMA, N
    SHIRAISHI, A
    HONDA, T
    TSUJIUCHI, J
    [J]. ACTA POLYTECHNICA SCANDINAVICA-APPLIED PHYSICS SERIES, 1985, (150): : 272 - 275
  • [48] Textual image compression at low bit rates based on region-of-interest coding
    Grailu, Hadi
    [J]. INTERNATIONAL JOURNAL ON DOCUMENT ANALYSIS AND RECOGNITION, 2016, 19 (01) : 65 - 81
  • [49] Progressive scalable interactive region-of-interest image coding using vector quantization
    Ebrahimi-Moghadam, A
    Shirani, S
    [J]. IEEE TRANSACTIONS ON MULTIMEDIA, 2005, 7 (04) : 680 - 687
  • [50] Adaptive CT for High-Resolution, Controlled-Dose, Region-of-Interest Imaging
    Moore, Jared W.
    Barrett, Harrison H.
    Furenlid, Lars R.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 4154 - 4157