Long-Period Grating Inscribed on Concatenated Double-Clad and Single-Clad Fiber for Simultaneous Measurement of Temperature and Refractive Index

被引:40
|
作者
Han, Qun [1 ,2 ,3 ]
Lan, Xinwei [1 ]
Huang, Jie [1 ]
Kaur, Amardeep [1 ]
Wei, Tao [1 ]
Gao, Zhan [1 ]
Xiao, Hai [1 ]
机构
[1] Missouri Univ Sci & Technol, Dept Elect & Comp Engn, Rolla, MO 65409 USA
[2] Tianjin Univ, Coll Precis Instrument & Optoelect Engn, Minist Educ, Tianjin 300072, Peoples R China
[3] Tianjin Univ, Key Lab Optoelect Informat Technol, Minist Educ, Tianjin 300072, Peoples R China
基金
中国国家自然科学基金;
关键词
Chemical sensors; fiber gratings; fiber sensors; REFRACTOMETER; WATER;
D O I
10.1109/LPT.2012.2196428
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this letter, a kind of long-period fiber grating (LPFG) that is capable of simultaneous measurement of temperature and surrounding refractive index (RI) is fabricated and demonstrated. The compact LPFG is written on a piece of spliced standard single-mode fiber (SMF) and double-clad fiber (DCF) with the CO2 laser point-by-point irradiation technique. The LPFG section in the DCF is solely sensitive to temperature, while the section of the LPFG in the SMF is sensitive to both temperature and surrounding RI. After temperature and RI calibration, the LPFG has been used to measure the RI change of ethylene glycol with the change of temperature to demonstrate its capability for dual parameter simultaneous measurement.
引用
收藏
页码:1130 / 1132
页数:3
相关论文
共 50 条
  • [21] Hybrid Long-Period Fiber Grating with Multimode Fiber Core for Refractive Index Measurement
    邵敏
    乔学光
    任学良
    杨德兴
    Chinese Physics Letters, 2017, 34 (11) : 45 - 48
  • [22] Hybrid Long-Period Fiber Grating with Multimode Fiber Core for Refractive Index Measurement
    邵敏
    乔学光
    任学良
    杨德兴
    Chinese Physics Letters, 2017, (11) : 45 - 48
  • [23] Toward 100 Micrometer per Refractive Index Unit Sensitive Sensor Using a Compact Long-Period Grating Inscribed Metal Clad Ridge Waveguide
    Saha, Nabarun
    Kumar, Arun
    JOURNAL OF LIGHTWAVE TECHNOLOGY, 2018, 36 (10) : 2024 - 2030
  • [24] Reflective long-period fiber grating-based sensor with Sagnac fiber loop mirror for simultaneous measurement of refractive index and temperature
    Yuan, Jianying
    Zhao, Chun-Liu
    Zhou, Yumeng
    Yu, Xiangdong
    Kang, Juan
    Wang, Jianfeng
    Jin, Shangzhong
    APPLIED OPTICS, 2014, 53 (29) : H85 - H90
  • [25] Simultaneous measurement of temperature and refractive index using a simplified modal interferometer composed of tilted long-period fiber grating and fiber bitaper
    Xue, Xiaolin
    Zhang, Weigang
    Zhang, Hao
    Gao, Shecheng
    Geng, Pengcheng
    Bai, Zhiyong
    Li, Jieliang
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (06)
  • [26] Sandwiched long-period gratings for simultaneous measurement of refractive index and temperature
    Zhang, AP
    Shao, LY
    Ding, JF
    He, SL
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2005, 17 (11) : 2397 - 2399
  • [27] Simultaneous measurement of refractive index and temperature using a single ultralong-period fiber grating
    Zhu, T
    Rao, YJ
    Mo, QJ
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2005, 17 (12) : 2700 - 2702
  • [28] Dispersion compensation of thin-clad chirped long-period fiber grating
    Gu, Zhengtian
    Jiang, Xiuli
    Guangxue Xuebao/Acta Optica Sinica, 2009, 29 (04): : 879 - 883
  • [29] Simultaneous measurement of temperature and refraction index based on multimode interference and long-period fiber grating
    Wang, Jieyu
    Tong, Zhengrong
    Yang, Xiufeng
    Cao, Ye
    Zhongguo Jiguang/Chinese Journal of Lasers, 2012, 39 (09):
  • [30] Sensing Characteristics of Helical Long-Period Gratings Written in the Double-Clad Fiber by CO2 Laser
    Cao, Xibiao
    Tian, Dandan
    Liu, Yunqi
    Zhang, Liang
    Wang, Tingyun
    IEEE SENSORS JOURNAL, 2018, 18 (18) : 7481 - 7485