Initial experience with the Gore® Acuseal graft for prosthetic vascular access

被引:37
|
作者
Tozzi, Matteo [1 ]
Franchin, Marco [2 ,3 ]
Ietto, Giuseppe [2 ,3 ]
Soldini, Gabriele [2 ,3 ]
Carcano, Giulio [2 ,3 ]
Castelli, Patrizio [1 ]
Piffaretti, Gabriele [1 ]
机构
[1] Univ Insubria, Sch Med, Circolo Univ Teaching Hosp, Ctr Res Organ Transplantat,Vasc Surg, Varese, Italy
[2] Univ Insubria, Sch Med, Circolo Univ Teaching Hosp, Gen Surg,Dept Surg & Morphol Sci, Varese, Italy
[3] Univ Insubria, Sch Med, Circolo Univ Teaching Hosp, Ctr Res Organ Transplantat, Varese, Italy
来源
JOURNAL OF VASCULAR ACCESS | 2014年 / 15卷 / 05期
关键词
Early cannulation; Gore (R) Acuseal; Prosthetic vascular access;
D O I
10.5301/jva.5000276
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: The purpose of this study is to report the short-term results of the Gore (R) Acuseal graft for prosthetic vascular access (pVA) in patients with end-stage renal disease on hemodialysis. Methods: Between October 2011 and October 2013, all the consecutive patients who underwent implantation of a new expanded Polytetrafluoroethylene (ePTFE) tri-layer graft were included in the study. Primary and secondary patency rate, time to first cannulation, and complications were recorded. Follow-up was performed at 1, 3, 6, and 12 months after the intervention. Results: Thirty ePTFE tri-layer heparin bonded grafts were implanted in 18 males and 12 females. The graft configuration was radial-basilic (n=12, 40%), brachial-basilic (n=10, 33.3%), femoro-femoral (n=3, 10.0%), radial-cephalic (n=2, 6.7%), radial-antecubital forearm (n=2, 6.7%), and brachial-axillary (n= 1, 3.3%). No patient was lost during a mean follow-up time of 6.3 +/- 5.9 months (range, 1-24; median, 5). Mean time to first cannulation was 2.4 +/- 1.2 days (range, 1-15). Primary functional patency rate was 68.0% +/- 10 at 6 and 12 months. Secondary patency rate was 93.3% +/- 6 at 6 and 12 months. Pseudoaneurysm, bleeding, seroma, or graft infection was never observed. Conclusions: In our experience, the Gore (R) Acuseal graft was useful and safe. Early cannulation was always performed, and structural complications did not occur. Primary functional and secondary patency rate are satisfactory in the short term.
引用
收藏
页码:385 / 390
页数:6
相关论文
共 50 条
  • [41] The United Kingdom and Ireland experience of the Haemodialysis Reliable Outflow graft for vascular access
    Hunter, James P.
    Knight, Simon R.
    Inston, N.
    Ridway, D.
    Tavakoli, A.
    Suttie, S.
    Kingsmore, D.
    Brown, T.
    Sultan, S.
    Gilbert, J.
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (01): : 12 - 18
  • [42] INITIAL RESUSCITATION AND VASCULAR ACCESS
    RIEGER, A
    BERMAN, JM
    STRIEBEL, HW
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1994, 32 (01) : 47 - 77
  • [43] Initial Experience Using the Gore Embolic Filter in Carotid Interventions
    Hornung, Marius
    Franke, Jennifer
    Bertog, Stefan C.
    Gafoor, Sameer
    Grunwald, Iris
    Sievert, Horst
    JOURNAL OF INVASIVE CARDIOLOGY, 2016, 28 (08): : 334 - 339
  • [44] Initial human experience with the GORE EXCLUDER Conformable AAA Endoprosthesis
    Rhee, Robert
    Peterson, Brian
    Moore, Erin
    Lepore, Michael
    Oderich, Gustavo
    JOURNAL OF VASCULAR SURGERY CASES AND INNOVATIVE TECHNIQUES, 2019, 5 (03): : 319 - 322
  • [45] Rapid Aortic Arch Debranching Using the Gore Hybrid Vascular Graft
    Levack, Melissa M.
    Bavaria, Joseph E.
    Gorman, Robert C.
    Gorman, Joseph H., III
    Ryan, Liam P.
    ANNALS OF THORACIC SURGERY, 2013, 95 (06): : E163 - E165
  • [46] Hemodialysis access declotting: A native fistula is not a prosthetic graft
    Turmel-Rodrigues, LA
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (01) : 135 - 136
  • [47] Early cannulation prosthetic graft (Flixene™) for arteriovenous access
    Schild, A. Frederick
    Schuman, Earl S.
    Noicely, Karlene
    Kaufman, Joyce
    Gillaspie, Erin
    Fuller, Joseph
    Collier, Patrick
    Ronfeld, Amy
    Nair, Rakesh Ravikumaran
    JOURNAL OF VASCULAR ACCESS, 2011, 12 (03): : 248 - 252
  • [48] Prosthetic vascular graft infection and prosthetic joint infection caused by Pseudomonas stutzeri
    Bonares, Michael J.
    Vaisman, Alon
    Sharkawy, Abdu
    IDCASES, 2016, 6 : 106 - 108
  • [49] Addressing early graft failure: Midterm results with the gore-tex Propaten Vascular Graft
    Peeters, P
    Bosiers, M
    Verbist, J
    Deloose, K
    JOURNAL OF ENDOVASCULAR THERAPY, 2004, 11 : 31 - 32
  • [50] INITIAL EXPERIENCE WITH A NEW PROSTHETIC ANGIOACCESS DEVICE
    GARRISON, RN
    WATHEN, RL
    RICHARDSON, KE
    TEMES, GD
    SOUTHERN MEDICAL JOURNAL, 1985, 78 (02) : 167 - 170