Progress towards a hand portable pulse tube refrigerator for high TC dc SQUID operation

被引:3
|
作者
Dolabdjian, C
Saez, S
Bloyet, D
David, M
Maréchal, JC
机构
[1] Inst Sci Mat & Rayonnement, CNRS UPRES A6072, GREYC, F-14050 Caen, France
[2] Univ Caen, F-14050 Caen, France
[3] ENS, F-75005 Paris, France
[4] Air Liquide DTA, F-38360 Grenoble, France
关键词
D O I
10.1016/S0964-1807(98)00117-3
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Compared to Stirling or Gifford-Mac Mahon crycoolers, the pulse tube refrigerator (PTR) has the advantage of having no moving parts in the cold stage. This results in lower levels of vibration, which is more suitable for the design of highly sensitive superconducting magnetometers. We describe a PTR system in which the compressor is connected to a cold part with a semi-flexible one meter long tube, under an average helium gas pressure of 3 MPa. Using a frequency of 30 Hz and a high to low pressure ratio of 1.5, the lowest temperature achieved is 56 K. The cooling power is 200 mW at 77 K with a cooling down time of about of 45 min. A bare YBaCuO de SQUID has been successfully operated at a temperature close to 77 K. The SQUID was mounted onto a copper block, attached to the cold head of the PTR. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:459 / 464
页数:6
相关论文
共 50 条
  • [1] Operation of a high-Tc DC-SQUID-gradiometer on a non-metallic pulse tube refrigerator
    Becker, C.
    Steppke, A.
    Koettig, T.
    Gerster, J.
    Doerrer, L.
    Thuerk, M.
    Schmidl, F.
    Seidel, P.
    8TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS'07), 2008, 97
  • [2] Pulse tube refrigerator for high-T-C squid operation
    Thummes, G
    Landgraf, R
    Giebeler, F
    Muck, M
    Heiden, C
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 41, PTS A AND B, 1996, : 1463 - 1470
  • [3] High-Tc DC SQUID system cooled by pulse-tube cooler
    He, DF
    Nakamura, M
    Yoshizawa, M
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2003, 392 : 1416 - 1419
  • [4] High-tc dc SQUID cooled by pulse-tube cooler and corrosion measurements
    He, DF
    Yoshizawa, M
    Yashiro, H
    Nakamura, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2005, 15 (01) : 40 - 43
  • [5] Performance investigation of Stirling-type nonmagnetic and nonmetallic pulse tube cryocoolers for high-Tc SQUID operation
    Dang, HZ
    Ju, YL
    Liang, JT
    Cai, JH
    Dai, W
    Zhou, Y
    CRYOCOOLERS 13, 2005, : 411 - 420
  • [6] Pulse tube refrigerator with displacer for near room temperature operation
    20171403535194
    (1) School of Mechanical Engineering, Tongji University, 4800, Cao'an Road, Shanghai; 201804, China, 1600, Chemours; Daikin Industries, Ltd.; Denso Corporation; et al.; Fuji Electric Co., Ltd.; Fujitsu General Limited (International Institute of Refrigeration):
  • [7] Progress in low noise cooling performance of a pulse-tube cooler for HT-SQUID operation
    Lienerth, C
    Thummes, G
    Heiden, C
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2001, 11 (01) : 812 - 815
  • [8] DC flow analysis and second orifice version pulse tube refrigerator
    Yang, LW
    Zhou, Y
    Liang, JT
    CRYOGENICS, 1999, 39 (03) : 187 - 192
  • [9] DC flow analysis and second orifice version pulse tube refrigerator
    Cryogenic Laboratory, Chinese Acad. Sci., Post B., Beijing, China
    Cryogenics, 3 (187-192):
  • [10] High-Tc and low-Tc dc SQUID electronics
    Drung, D