DC flow analysis and second orifice version pulse tube refrigerator

被引:10
|
作者
Yang, LW [1 ]
Zhou, Y [1 ]
Liang, JT [1 ]
机构
[1] Chinese Acad Sci, Cryogen Lab, Beijing 100080, Peoples R China
基金
中国国家自然科学基金;
关键词
pulse tube refrigerator; DC flow and its direction; second orifice; experiment;
D O I
10.1016/S0011-2275(99)00029-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper analyzes direct current flow (DC flow) due to double-inlet, and introduces a second orifice version pulse tube refrigerator experiment to diminish DC flow. Analysis based on some assumptions shows that DC flow through the double-inlet valve in the pulse tube refrigerator is not generally zero, and the DC flow direction may change when the pressure wave changes. Thus, different schemes should be developed for different DC flow directions. In experiments, through measuring the change of temperature near the hot end of the pulse tube, DC flow direction different from former in pulse tube is decided. The second orifice is arranged from the second-stage reservoir to high pressure of the compressor, instead of the traditional arrangement of from the reservoir to low pressure. Experiments with the newly arranged second orifice show that the lowest temperature is about 4 K lower than without the second orifice. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [1] DC flow analysis and second orifice version pulse tube refrigerator
    Cryogenic Laboratory, Chinese Acad. Sci., Post B., Beijing, China
    Cryogenics, 3 (187-192):
  • [2] Analysis of mass and energy flow rates in an orifice pulse-tube refrigerator
    Kuriyama, F
    Radebaugh, R
    CRYOGENICS, 1999, 39 (01) : 85 - 92
  • [3] A model for energy and exergy flow in an orifice pulse tube refrigerator
    Razani, A
    Dodson, C
    Abhyankar, NS
    Flake, B
    CRYOCOOLERS 13, 2005, : 353 - 362
  • [4] Visualization of DC gas flows in a double-inlet pulse tube refrigerator with a second orifice valve
    Shiraishi, M
    Takamatsu, K
    Murakami, M
    Nakano, A
    Iida, T
    Hozumi, Y
    CRYOCOOLERS 11, 2001, : 371 - 379
  • [5] Second order cyclic analysis of counter flow pulse tube refrigerator
    Choudhari, Mahmadrafik
    Gawali, Bajirao
    Malwe, Prateek
    Deshmukh, Nandkishor
    Dhalait, Rustum
    JOURNAL OF THERMAL ENGINEERING, 2023, 9 (03): : 580 - 592
  • [6] Analysis of an orifice pulse tube refrigerator using the method of characteristics
    Xu, MY
    He, YL
    Chen, ZQ
    CRYOGENICS, 1999, 39 (09) : 751 - 757
  • [7] IDEAL ORIFICE PULSE TUBE REFRIGERATOR PERFORMANCE
    KITTEL, P
    CRYOGENICS, 1992, 32 (09) : 843 - 844
  • [8] NUMERICAL MODELING OF AN ORIFICE PULSE TUBE REFRIGERATOR
    WANG, C
    WU, PY
    CHEN, ZQ
    CRYOGENICS, 1992, 32 (09) : 785 - 790
  • [9] THEORY OF IDEAL ORIFICE PULSE TUBE REFRIGERATOR
    DAVID, M
    MARECHAL, JC
    SIMON, Y
    GUILPIN, C
    CRYOGENICS, 1993, 33 (02) : 154 - 161
  • [10] System design of orifice pulse-tube refrigerator using linear flow network analysis
    Huang, BJ
    Chuang, MD
    CRYOGENICS, 1996, 36 (11) : 889 - 902