DC flow analysis and second orifice version pulse tube refrigerator

被引:10
|
作者
Yang, LW [1 ]
Zhou, Y [1 ]
Liang, JT [1 ]
机构
[1] Chinese Acad Sci, Cryogen Lab, Beijing 100080, Peoples R China
基金
中国国家自然科学基金;
关键词
pulse tube refrigerator; DC flow and its direction; second orifice; experiment;
D O I
10.1016/S0011-2275(99)00029-6
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper analyzes direct current flow (DC flow) due to double-inlet, and introduces a second orifice version pulse tube refrigerator experiment to diminish DC flow. Analysis based on some assumptions shows that DC flow through the double-inlet valve in the pulse tube refrigerator is not generally zero, and the DC flow direction may change when the pressure wave changes. Thus, different schemes should be developed for different DC flow directions. In experiments, through measuring the change of temperature near the hot end of the pulse tube, DC flow direction different from former in pulse tube is decided. The second orifice is arranged from the second-stage reservoir to high pressure of the compressor, instead of the traditional arrangement of from the reservoir to low pressure. Experiments with the newly arranged second orifice show that the lowest temperature is about 4 K lower than without the second orifice. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:187 / 192
页数:6
相关论文
共 50 条
  • [41] Investigations on nonlinear processes of a Gifford-McMahon type orifice pulse tube refrigerator
    Panda, Debashis
    Kumar, Manoj
    Satapathy, Ashok K.
    Sarangi, S. K.
    Behera, Upendra
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024, 238 (06) : 2797 - 2808
  • [42] Optimal Design of Orifice Pulse Tube Refrigerator Based on Response Surface and Genetic Algorithm
    Rout, Sachindra Kumar
    Sahoo, Ranjit Kumar
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2016, 41 (05) : 1735 - 1755
  • [43] THEORY OF THE IDEAL ORIFICE PULSE TUBE REFRIGERATOR (VOL 33, PG 154, 1993)
    DAVID, M
    MARECHAL, JC
    SIMON, Y
    GUILPIN
    CRYOGENICS, 1993, 33 (04) : 472 - 472
  • [44] Temperature loop, a new phenomenon in a GM-type orifice pulse tube refrigerator
    Gan, Zhi-Hua
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2005, 26 (03): : 388 - 390
  • [45] Experimental study on a double-orifice two-stage pulse tube refrigerator
    Chen, G
    Qiu, L
    Zheng, J
    Yan, P
    Gan, Z
    Bai, X
    Huang, Z
    CRYOGENICS, 1997, 37 (05) : 271 - 273
  • [46] DC flow in pulse tube coolers
    Hofmann, A
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 47, PTS A AND B, 2002, 613 : 911 - 917
  • [47] Double vortex tube as heat exchanger and flow impedance for a pulse tube refrigerator
    Mitchell, MP
    Fabris, D
    Tomlinson, BJ
    CRYOCOOLERS 10, 1999, : 257 - 264
  • [48] Visualization study of oscillating flow inside a pulse tube refrigerator
    Nakamura, N
    Shiraishi, M
    Seo, K
    Murakami, M
    ADVANCES IN CRYOGENIC ENGINEERING, VOL 43 PTS A AND B, 1998, 43 : 2023 - 2030
  • [49] INVESTIGATION OF PULSE TUBE REFRIGERATOR
    NARAYANK.KG
    MANE, VD
    MECHANICAL ENGINEERING, 1973, 95 (04) : 67 - 67
  • [50] THERMODYNAMIC ANALYSIS OF THE BASIC PULSE-TUBE REFRIGERATOR