Semiempirical thermodynamic modeling of a direct methanol fuel cell system

被引:18
|
作者
Ince, Alper Can [1 ,2 ]
Karaoglan, Mustafa Umut [1 ,3 ]
Gluesen, Andreas [4 ]
Colpan, C. Ozgur [1 ,3 ]
Mueller, Martin [4 ]
Stolten, Detlef [4 ,5 ]
机构
[1] Dokuz Eylul Univ, Mech Engn Dept, Grad Sch Nat & Appl Sci, TR-35397 Izmir, Turkey
[2] Gebze Tech Univ, Mech Engn Dept, Fac Engn, TR-41400 Kocaeli, Turkey
[3] Dokuz Eylul Univ, Mech Engn Dept, Fac Engn, TR-35397 Izmir, Turkey
[4] Forschungszentrum Julich, Inst Energy & Climate Res Electrochem Proc Engn I, D-52425 Julich, Germany
[5] Rhein Westfal TH Aachen, Chair Fuel Cells, D-52072 Aachen, Germany
关键词
condenser outlet temperature; direct methanol fuel cell; electrical efficiency; semiempirical; thermodynamics; WATER CROSSOVER; OPERATING PARAMETERS; DMFC SYSTEM; PERFORMANCE; MEMBRANE; SIMULATION; CHALLENGE; POWER;
D O I
10.1002/er.4508
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, a thermodynamic model of an active direct methanol fuel cell (DMFC) system, which couples in-house experimental data for the DMFC with the mass and energy balances for the system components (condenser, mixing vessel, blower, and pumps), is formed. The modeling equations are solved using the Engineering Equation Solver (EES) program. This model gives the mass fluxes and thermodynamic properties of fluids for each state, heat and work transfer between the components and their surroundings, and electrical efficiency of the system. The effect of the methanol concentration (between 0.5 and 1.25 M) and air flow rate (between 20 and 30 mL cm(-2) min(-1)) on the net power output and electrical efficiency of the system and the condenser outlet temperature is investigated. The results essentially showed that the highest value for the electrical efficiency of the system is 23.6% when the current density, methanol concentration, and air flow rate are taken as 0.2 A cm(-2), 0.75 M, and 20 mL cm(-2) min(-1), respectively. In addition, the air flow rate was found to be the most significant parameter affecting the condenser outlet temperature.
引用
收藏
页码:3601 / 3615
页数:15
相关论文
共 50 条
  • [11] Direct methanol fuel cell system reliability analysis
    Deodath, R.
    Jhingoorie, J.
    Riverol, C.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2017, 42 (16) : 12032 - 12045
  • [12] A Power Management System for Direct Methanol Fuel Cell
    Song, H. J.
    Lee, S. J.
    Yoo, E. J.
    Park, H. J.
    Noh, M. G.
    Park, Y. W.
    TENCON 2012 - 2012 IEEE REGION 10 CONFERENCE: SUSTAINABLE DEVELOPMENT THROUGH HUMANITARIAN TECHNOLOGY, 2012,
  • [13] Process system engineering in direct methanol fuel cell
    Basri, S.
    Kamarudin, S. K.
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2011, 36 (10) : 6219 - 6236
  • [14] Engineering aspects of the direct methanol fuel cell system
    Scott, K
    Taama, WM
    Argyropoulos, P
    JOURNAL OF POWER SOURCES, 1999, 79 (01) : 43 - 59
  • [15] Power management of a direct methanol fuel cell system
    Jiang, Rongzhong
    Chu, Deryn
    JOURNAL OF POWER SOURCES, 2006, 161 (02) : 1192 - 1197
  • [16] Modeling the transient temperature distribution in a direct methanol fuel cell
    Ramesh, Vaidhiswaran
    Krishnamurthy, Balaji
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 809 : 1 - 7
  • [17] Modeling of passive alkaline membrane direct methanol fuel cell
    Deng, Hao
    Jiao, Daokuan
    Zu, Meng
    Chen, Jixin
    Jiao, Kui
    Huang, Xuri
    ELECTROCHIMICA ACTA, 2015, 154 : 430 - 446
  • [18] Modeling the cathode catalyst layer of a Direct Methanol Fuel Cell
    Matar, Saif
    Ge, Jiabin
    Liu, Hongtan
    JOURNAL OF POWER SOURCES, 2013, 243 : 195 - 202
  • [19] Mixed potential in a direct methanol fuel cell - Modeling and experiments
    Liu, Fuqiang
    Wang, Chao-Yang
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2007, 154 (06) : B514 - B522
  • [20] Modeling of spontaneous hydrogen evolution in a direct methanol fuel cell
    Ye, Qiang
    Yang, Xiao-Guang
    Cheng, Ping
    ELECTROCHIMICA ACTA, 2012, 69 : 230 - 238