Utility Decay Rates of T1-Weighted Magnetic Resonance Imaging Contrast Based on Redox-Sensitive Paramagnetic Nitroxyl Contrast Agents

被引:9
|
作者
Matsumoto, Ken-ichiro [1 ,2 ]
机构
[1] Natl Inst Radiol Sci, Radiat Modifier Team, Heavy Ion Radiobiol Res Grp, Res Ctr Charged Particle Therapy,Inage Ku, Chiba 2638555, Japan
[2] NCI, Radiat Biol Branch, Ctr Canc Res, NIH, Bethesda, MD 20892 USA
关键词
nitroxyl contrast agent; redox mapping; T-1-weighted contrast; magnetic resonance imaging; tissue redox status; tumor imaging; FLOW MONITORING BFM; X-BAND EPR; SPIN LABELS; SUBCELLULAR-FRACTIONS; TUMOR; REDUCTION; OXYGEN; LIVER; METABOLISM; SPECTROSCOPY;
D O I
10.1248/bpb.32.711
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The availability and applicability of the combination of paramagnetic nitroxyl contrast agent and T-1-weighted gradient echo (GE)-based dynamic magnetic resonance imaging (MRI) measurement for redox imaging are described. The time courses of T-1-weighted GE MRI signal intensities according to first-order paramagnetic loss of a nitroxyl contrast agent were simulated for several experimental conditions. The apparent decay rate calculated based on decreasing T-1-weighted MRI contrast (k(MRI))can show an approximate value of the original decay rate (k(true)) discretionarily given for simulation with suitable experimental parameters. The difference between k(MRI) and k(true) can be sufficiently small under T-1-weighted spoiled gradient echo (SPGR) scan conditions (repetition time=75 ms, echo time=3 ms, and flip angle=45 degrees), with a conventional redox-sensitive nitroxyl contrast agent, such as 4-hydroxy-2,2,6,6,-tetramethylpiperidine-N-oxyl (TEMPOL) and/or 3-carbamoyl-2,2,5,5-tetramethylpyrrolidine-N-oxyl (carbamoyl-PROXYL), and with i.v. doses of below 1.5 mu mol/g b.w. for mice. The results of this simulation suggest that the k(MRI) of nitroxyl contrast agents can be the primary index of redox status under biological conditions.
引用
收藏
页码:711 / 716
页数:6
相关论文
共 50 条
  • [41] Large-scale synthesis of biodegradable iron-based contrast agent for high performance T1-weighted magnetic resonance imaging
    Huang, Ya
    Xiong, Wei
    Qin, Xiang
    Fan, Qingdeng
    Ren, Bin
    Wu, Guochao
    Zhou, Ruilong
    Yan, Chenggong
    Liu, Gang
    Xu, Jun
    Shen, Zheyu
    CHEMICAL ENGINEERING JOURNAL, 2025, 509
  • [42] High-concentration iodinated contrast media for T1-weighted direct magnetic resonance arthrography
    Huang, Y. -F.
    Hsieh, T. -J.
    Chen, Y. -J.
    Chen, H. -S.
    Kuo, Y. -T.
    Yang, Y. -H.
    CLINICAL RADIOLOGY, 2018, 73 (10) : 907.e1 - 907.e7
  • [43] One-pot Synthesis of PEGylated Gd-based Nanoparticles as High-performance and Biocompatibility Contrast Agents for T1-Weighted Magnetic Resonance Imaging In vivo
    Huang Sa
    Han Qinghe
    Wang Lei
    Gong Tingting
    Yuan Qinghai
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2019, 35 (03) : 537 - 541
  • [44] One-pot Synthesis of PEGylated Gd-based Nanoparticles as High-performance and Biocompatibility Contrast Agents for T1-Weighted Magnetic Resonance Imaging In vivo
    Sa Huang
    Qinghe Han
    Lei Wang
    Tingting Gong
    Qinghai Yuan
    Chemical Research in Chinese Universities, 2019, 35 : 537 - 541
  • [45] Magnetic iron oxide nanoparticles as T1 contrast agents for magnetic resonance imaging
    Bao, Y.
    Sherwood, J. A.
    Sun, Z.
    JOURNAL OF MATERIALS CHEMISTRY C, 2018, 6 (06) : 1280 - 1290
  • [46] Activatable T1 and T2 Magnetic Resonance Imaging Contrast Agents
    Chuqiao Tu
    Elizabeth A. Osborne
    Angelique Y. Louie
    Annals of Biomedical Engineering, 2011, 39 : 1335 - 1348
  • [47] Iron(III)-based contrast agents for magnetic resonance imaging
    Depts. Chem. Med. and Biol. Chem., The University of Toledo, Toledo, OH 43606, United States
    不详
    Polyhedron, 19 (2457-2482):
  • [48] Iron(III)-based contrast agents for magnetic resonance imaging
    Richardson, N
    Davies, JA
    Radüchel, B
    POLYHEDRON, 1999, 18 (19) : 2457 - 2482
  • [49] Magnetic resonance imaging contrast agents based on albumin nanoparticles
    Yuan, Yuan
    Gao, Hui
    Jiang, Sunmin
    You, Qingjun
    Zhou, Juan
    Chen, Jinghua
    BIOMATERIALS SCIENCE, 2025, 13 (02) : 408 - 421
  • [50] Contrast-enhanced FLAIR Versus Contrast-enhanced T1-Weighted Sequence of Magnetic Resonance Imaging for the Evaluation of Leptomeningeal Disease: Which one is Better?
    Tepe, Savas
    NOROPSIKIYATRI ARSIVI-ARCHIVES OF NEUROPSYCHIATRY, 2012, 49 (02): : 108 - 113