Fully discharging phases - A new approach to biphasic waveforms for external defibrillation

被引:8
|
作者
Yamanouchi, Y
Brewer, JE
Olson, KF
Mowrey, KA
Mazgalev, TN
Wilkoff, BL
Tchou, PJ
机构
[1] Cleveland Clin Fdn, Dept Cardiol F15, Clin Cardiac Electrophysiol, Cleveland, OH 44195 USA
[2] SurVivaLink Corp, Minneapolis, MN USA
关键词
defibrillation; death; sudden; ventricles;
D O I
10.1161/01.CIR.100.8.826
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Phase-2 voltage and maximum pulse width are dependent on phase-1 pulse characteristics in a single-capacitor biphasic waveform. The use of 2 separate output capacitors avoids these limitations and may allow waveforms with lower defibrillation thresholds. A previous report also suggested that the optimal tilt may be >70%. This study was designed to determine an optimal biphasic waveform by use of a combination of 2 separate and fully (95% tilt) discharging capacitors. Methods and Results-We performed 2 external defibrillation studies in a pig ventricular fibrillation model. In group I, 9 waveforms from a combination of 3 phase-1 capacitor values (30, 60, and 120 mu F) and 3 phase-2 capacitor values (0=monophasic, 1/3, and 1.0 times the phase-1 capacitor) were tested. Biphasic waveforms with phase-2 capacitors of 1/3 times that of phase 1 provided the highest defibrillation efficacy (stored energy and voltage) compared with corresponding monophasic and biphasic waveforms with the same capacitors in both phases except for waveforms with. a 30-mu F phase-1 capacitor. In group 2, 10 biphasic waveforms from a combination of 2 phase-1 capacitor values (30 and 60 mu F) and 5 phase-2 capacitor values (10, 20, 30, 40, and 50 mu F) were tested. In this range, phase-2 capacitor size was more critical for the 30-mu F phase-1 than for the 60-mu F phase-1 capacitor. The optimal combinations of fully discharging capacitors for defibrillation were 60/20 and 60/30 mu F Conclusions-Phase-2 capacitor size plays an important role in reducing defibrillation energy in biphasic waveforms when 2 separate and fully discharging capacitors are used.
引用
收藏
页码:826 / 831
页数:6
相关论文
共 50 条
  • [41] COMPARATIVE EFFICACY OF MONOPHASIC AND BIPHASIC WAVEFORMS FOR NON-THORACOTOMY CANINE DEFIBRILLATION
    CHAPMAN, PD
    VETTER, JW
    SOUZA, JJ
    TROUP, PJ
    WETHERBEE, JN
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (04): : 497 - 497
  • [42] Biphasic waveforms prevent the chronic rise of defibrillation thresholds with a transvenous lead system
    Gold, MR
    Kavesh, NG
    Peters, RW
    Shorofsky, SR
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1997, 30 (01) : 233 - 236
  • [43] Biphasic waveforms for ventricular defibrillation: Optimization of total pulse and second phase durations
    Matula, MH
    Brooks, MJ
    Pan, Q
    Pless, BD
    Province, RA
    Echt, DS
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (09): : 2154 - 2162
  • [44] Early postoperative rise in defibrillation threshold in patients with nonthoracotomy defibrillation lead systems: Attenuation with biphasic shock waveforms
    Schwartzman, D
    Callans, DJ
    Gottlieb, CD
    Heo, J
    Marchlinski, FE
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1996, 7 (06) : 483 - 493
  • [45] The efficacy and safety of external biphasic defibrillation in toy breed dogs
    Lee, Seung-Gon
    Moon, Hyeong-Sun
    Hyun, Changbaig
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2008, 18 (04) : 362 - 369
  • [46] Predictors of defibrillation threshold in biphasic external cardioversion of atrial fibrillation
    Miracapillo, G
    Costoli, A
    Addonisio, L
    Severi, S
    EUROPEAN HEART JOURNAL, 2004, 25 : 494 - 494
  • [47] Transthoracic defibrillation with new waveforms: Experimental studies
    Allan, JJ
    PaganCarlo, I
    Spencer, KT
    Birkett, C
    Smith, R
    Kerber, RE
    JOURNAL OF INVESTIGATIVE MEDICINE, 1996, 44 (03) : A211 - A211
  • [48] Biphasic versus monophasic waveforms for transthoracic defibrillation in out-of-hospital cardiac arrest
    Faddy, Steven C.
    Jennings, Paul A.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2016, (02):
  • [49] Highly successful atrial defibrillation using low-energy biphasic waveforms with no tilt
    Walsh, SJ
    Manoharan, G
    Santos, J
    Escalonal, OJ
    Evans, N
    Allen, JD
    Anderson, JMCC
    Adgey, AAJ
    EUROPEAN HEART JOURNAL, 2002, 23 : 287 - 287
  • [50] Is there an optimal shape of the defibrillation shock: Constant current vs. pulsed biphasic waveforms?
    Dotsinsky, Ivan
    Mudrov, Tsvetan
    Krasteva, Vessela
    Kostov, Jecho
    International Journal Bioautomation, 2013, 17 (01) : 45 - 56