Mesoporous MnO2 as enzyme immobilization host for amperometric glucose biosensor construction

被引:51
|
作者
Yu, Jingjing [1 ]
Zhao, Tian [1 ]
Zeng, Baizhao [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Hubei Province, Peoples R China
关键词
mesoporous MnO2; glucose oxidase; biosensor; amperometry; glucose;
D O I
10.1016/j.elecom.2008.06.028
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Mesoporous MnO2 (mesoMnO(2)) is synthesized facilely through sol-gel process using nonionic surfactant polyxyethylene fatty alcohol (AEO(9)) as template. Transmission electron microscopy (TEM) image and N-2 adsorption/desorption isotherm show that the obtained mesoMnO(2) material presents disordered porous structure and appropriate pore size suitable for the immobilization of glucose oxidase (GOx). An amperometric glucose biosensor based on GOx entrapped in mesoMnO(2) is fabricated, in which mesoMnO(2) also acts as a catalyst for the electrochemical oxidation of H2O2 produced by enzyme reaction. The biosensor shows fast and sensitive current response to glucose in the linear range of 0.0009-2.73 mM. The response time (t(95%)) is less than 7 s. The sensitivity and detection limit are 24.2 mu A cm(-2) mM(-1) and 1.8 x 10(-7) M (S/N = 3), respectively. This indicates that mesoMnO(2) has promising application in enzyme immobilization and biosensor construction. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1318 / 1321
页数:4
相关论文
共 50 条
  • [42] Ceramic carbon/polypyrrole materials for the construction of bienzymatic amperometric biosensor for glucose
    Tian, FM
    Zhu, LD
    Xu, B
    Zhu, GY
    CHINESE CHEMICAL LETTERS, 2001, 12 (11) : 1011 - 1014
  • [43] Mesoporous Jarosite/MnO2 and Goethite/MnO2 Nanocomposites Synthesis And Application for Oxidation of Methylene Blue
    M. Sabbaghan
    F. Adhami
    M. Aminnezhad
    Journal of Structural Chemistry, 2018, 59 : 463 - 473
  • [44] MESOPOROUS JAROSITE/MnO2 AND GOETHITE/MnO2 NANOCOMPOSITES SYNTHESIS AND APPLICATION FOR OXIDATION OF METHYLENE BLUE
    Sabbaghan, M.
    Adhami, F.
    Aminnezhad, M.
    JOURNAL OF STRUCTURAL CHEMISTRY, 2018, 59 (02) : 463 - 473
  • [45] Development of a bienzymatic amperometric biosensor to determine uric acid in human serum, based on mesoporous silica (MCM-41) for enzyme immobilization
    Mundaca-Uribe, Rudolfo
    Bustos-Ramirez, Francisca
    Zaror-Zaror, Claudio
    Aranda-Bustos, Mario
    Neira-Hinojosa, Jose
    Pena-Farfal, Carlos
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 195 : 58 - 62
  • [46] Construction of an MnO2 nanosheet array 3D integrated electrode for sensitive enzyme-free glucose sensing
    Huang, M.
    Feng, S.
    Yang, C.
    Wen, F.
    He, D.
    Jiang, P.
    ANALYTICAL METHODS, 2021, 13 (10) : 1247 - 1254
  • [47] Amperometric hydrogen peroxide and glucose biosensor based on NiFe2/ordered mesoporous carbon nanocomposites
    Xiang, Dong
    Yin, Longwei
    Ma, Jingyun
    Guo, Enyan
    Li, Qun
    Li, Zhaoqiang
    Liu, Kegao
    ANALYST, 2015, 140 (02) : 644 - 653
  • [48] IMMOBILIZATION OF GLUCOSE OXIDASE IN SILICA SOL-GEL FILM FOR APPLICATION TO BIOSENSOR AND AMPEROMETRIC DETERMINATION OF GLUCOSE
    Demirkiran, Nizamettin
    Ekinci, Ergun
    Asilturk, Meltem
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2012, 57 (04) : 1336 - 1339
  • [49] Reagentless amperometric glucose biosensor based on the immobilization of glucose oxidase on a ferrocene@NaY zeolite composite
    Dong, Junping
    Zhou, Xiaojuan
    Zhao, Hongbin
    Xu, Jiaqiang
    Sun, Youbao
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 281 - 288
  • [50] An amperometric glucose biosensor based on the immobilization of glucose oxidase on the CuGeO3 nanowire modified electrode
    Yong Ping Dong
    Li Huang
    Xiang Feng Chu
    Li Zhai Pei
    Russian Journal of Electrochemistry, 2013, 49 : 571 - 576