Dynamic T-1 measurement using snapshot-FLASH MRI

被引:25
|
作者
Jivan, A [1 ]
Horsfield, MA [1 ]
Moody, AR [1 ]
Cherryman, GR [1 ]
机构
[1] UNIV LEICESTER,LEICESTER ROYAL INFIRM,DEPT PHYS MED,LEICESTER LE1 5WW,LEICS,ENGLAND
关键词
D O I
10.1006/jmre.1997.1177
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of an inversion-recovery snapshot FLASH (f ast low-angled shot) imaging sequence to the dynamic measurement of monoexponential T-1 relaxation was investigated, The effect of(a) a reduction in the overall sequence repetition time, and (b) an increase of the read-pulse flip angle, on the measurement of T-1 was analyzed, The error in T-1 introduced by these factors is calculated, and a fuller analysis that takes them into account is presented, Data from a phantom are used to confirm this analysis. The magnitude of the errors is illustrated by measuring myocardial T-1 in patients with acute ischaemic heart disease during the injection of a bolus of the contrast medium gadobenate dimeglumine. Overall, there was a 10% difference between the T-1 values when the approximate and exact solutions were used; this was statistically significant, However, the difference was on average 25% for patients with a high heart rate (because of the shorter sequence-repetition time) in areas of infarcted myocardium (because of the longer T-1). (C) 1997 Academic Press.
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [21] Teleultrasound using ATM over a T-1 satellite connection
    Williamson, MP
    Suitor, C
    deTreville, R
    Freckleton, M
    Kinsey, V
    Goeringer, F
    Lyche, D
    Hunter, B
    Jennings, N
    Shelton, P
    Marcy, J
    Poore, T
    North, J
    IMAGE DISPLAY: MEDICAL IMAGING 1996, 1996, 2707 : 662 - 667
  • [22] Measurement of spin-lattice relaxation times with FLASH for dynamic MRI of the breast
    Brookes, JA
    Redpath, TW
    Gilbert, FJ
    Needham, G
    Murray, AD
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (819): : 206 - 214
  • [23] Noninvasive measurement of cartilage biomechanics using T1β MRI
    Wheaton, AJ
    Corbo, MT
    Elliott, DM
    Nicoll, SB
    Dodge, GR
    Reddy, R
    OSTEOARTHRITIS AND CARTILAGE, 2004, 12 : S21 - S21
  • [24] Reduced Magnetic Coupling in Ultrasmall Iron Oxide T-1 MRI Contrast Agents
    Starsich, Fabian H. L.
    Eberhardt, Christian
    Keevend, Kerda
    Boss, Andreas
    Hirt, Ann M.
    Herrmann, Inge K.
    Pratsinis, Sotiris E.
    ACS APPLIED BIO MATERIALS, 2018, 1 (03) : 783 - 791
  • [25] Effect of long TE on T-1 measurement in STEAM progressive saturation experiment
    Knight-Scott, J
    Li, SJ
    JOURNAL OF MAGNETIC RESONANCE, 1997, 126 (02) : 266 - 269
  • [26] MEASUREMENT OF OER AND RBE OF A 910 MEV HELIUM ION-BEAM, USING CULTURED CELLS (T-1)
    RAJU, MR
    GNANAPURANI, M
    MARTINS, B
    LYMAN, JT
    HOWARD, J
    RADIOLOGY, 1972, 102 (02) : 425 - +
  • [27] Dynamic contrast-enhanced quantitative perfusion measurement of the brain using T1-weighted MRI at 3T
    Larsson, Henrik B. W.
    Hansen, Adam E.
    Berg, Hilde K.
    Rostrup, Egill
    Haraldseth, Olav
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 754 - 762
  • [28] T-1/4-NOISE FOR RANDOM WALKS IN DYNAMIC ENVIRONMENT ON Z
    Boldrighini, C.
    Pellegrinotti, A.
    MOSCOW MATHEMATICAL JOURNAL, 2001, 1 (03) : 365 - 380
  • [29] RAPID METHOD FOR COMBINED X-(H-1) NOE AND T-1 MEASUREMENT USING HETERONUCLEAR POLARIZATION TRANSFER
    KOVER, KE
    FORGO, P
    BATTA, G
    MAGNETIC RESONANCE IN CHEMISTRY, 1995, 33 (11) : 871 - 873
  • [30] Measurement Extraction using Fuzzy Set Rule for Segmented Features of Brain Tumor in T-1 & T-2 Weighted Images
    Singh, Manini
    Nigam, Vineeta Saxena
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (47A) : 742 - 749