Dynamic T-1 measurement using snapshot-FLASH MRI

被引:25
|
作者
Jivan, A [1 ]
Horsfield, MA [1 ]
Moody, AR [1 ]
Cherryman, GR [1 ]
机构
[1] UNIV LEICESTER,LEICESTER ROYAL INFIRM,DEPT PHYS MED,LEICESTER LE1 5WW,LEICS,ENGLAND
关键词
D O I
10.1006/jmre.1997.1177
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The application of an inversion-recovery snapshot FLASH (f ast low-angled shot) imaging sequence to the dynamic measurement of monoexponential T-1 relaxation was investigated, The effect of(a) a reduction in the overall sequence repetition time, and (b) an increase of the read-pulse flip angle, on the measurement of T-1 was analyzed, The error in T-1 introduced by these factors is calculated, and a fuller analysis that takes them into account is presented, Data from a phantom are used to confirm this analysis. The magnitude of the errors is illustrated by measuring myocardial T-1 in patients with acute ischaemic heart disease during the injection of a bolus of the contrast medium gadobenate dimeglumine. Overall, there was a 10% difference between the T-1 values when the approximate and exact solutions were used; this was statistically significant, However, the difference was on average 25% for patients with a high heart rate (because of the shorter sequence-repetition time) in areas of infarcted myocardium (because of the longer T-1). (C) 1997 Academic Press.
引用
下载
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [1] Dynamic T1 Measurement Using Snapshot-FLASH MRI
    Department of Radiology, University of Leicester, Leicester Royal Infirmary, Leicester LEI 5WW, United Kingdom
    不详
    不详
    J. Magn. Reson., 1 (65-72):
  • [2] T1 MAPS BY K-SPACE REDUCED SNAPSHOT-FLASH MRI
    NEKOLLA, S
    GNEITING, T
    SYHA, J
    DEICHMANN, R
    HAASE, A
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (02) : 327 - 332
  • [3] DYNAMIC INVERSION-RECOVERY SNAPSHOT-FLASH MRI OF HEPATIC FOCAL NODULAR HYPERPLASIA
    URHAHN, R
    KLOSE, KC
    DROBNITZKY, M
    BOHNDORF, K
    GUNTHER, RW
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1993, 158 (02): : 104 - 108
  • [4] QUANTIFICATION OF T1 VALUES BY SNAPSHOT-FLASH NMR IMAGING
    DEICHMANN, R
    HAASE, A
    JOURNAL OF MAGNETIC RESONANCE, 1992, 96 (03): : 608 - 612
  • [5] DYNAMIC CONTRAST ENHANCEMENT OF INTRACRANIAL TUMORS WITH SNAPSHOT-FLASH MR IMAGING
    NAGELE, T
    PETERSEN, D
    KLOSE, U
    GRODD, W
    OPITZ, H
    GUT, E
    MARTOS, J
    VOIGT, K
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1993, 14 (01) : 89 - 98
  • [6] MRI DIAGNOSIS OF DISSECTING AORTIC-ANEURYSMS BY MEANS OF FLASH-SEQUENCES AND SNAPSHOT-FLASH SEQUENCES
    BRAITINGER, S
    KETT, H
    HELD, P
    BREIT, A
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1992, 156 (02): : 151 - 155
  • [7] FURTHER OBSERVATIONS ON THE MEASUREMENT OF TISSUE T-1 TO MONITOR TEMPERATURE IN-VIVO BY MRI
    YOUNG, IR
    HAND, JW
    OATRIDGE, A
    PRIOR, MV
    FORSE, GR
    MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (03) : 342 - 345
  • [8] SNAPSHOT FLASH MRI - APPLICATIONS TO T1, T2, AND CHEMICAL-SHIFT IMAGING
    HAASE, A
    MAGNETIC RESONANCE IN MEDICINE, 1990, 13 (01) : 77 - 89
  • [9] Quantification of tumour microvascular permeability in human glioma xenografts using dynamic T-1 MRI with Gadomer-17
    Verhoye, M
    van der Sanden, BPJ
    Rijken, P
    Peters, H
    Van der Kogel, AJ
    Pee, G
    Vanhoutte, G
    Heerschap, A
    Van der Linden, A
    MEDICAL IMAGING 1999: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1999, 3660 : 418 - 428
  • [10] COMPARISON OF T-1 ESTIMATION TECHNIQUES IN CARDIAC MRI
    WALKER, PM
    MARIE, PY
    DANCHIN, N
    BERTRAND, A
    MAGNETIC RESONANCE IMAGING, 1994, 12 (01) : 43 - 50