RESEARCH ON THE SHAKING TABLE TEST MODEL OF PCS STORAGE TANK OF AP1000 NUCLEAR POWER ENGINEERING

被引:0
|
作者
Xiong, Jie [1 ]
机构
[1] China Nucl Ind 22nd Construct Co Ltd, Nucl Power Engn Management Ctr, Yichang 443101, Hubei, Peoples R China
来源
PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 2 | 2017年
关键词
Liquid storage tanks (LST); shaking table test; fluid-structure interaction (FSI); experimental models; PCS storage tank;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Since the responses of Liquid storage tanks (LST) include the liquid motion, structural motion, and fluid-structure interaction (FSI) under the earthquake ground motion, it is a difficult problem about shaking table test model for satisfying similarity ratio requirement. The two experimental models, namely satisfied FSI similarity ratio model (FSI model) and unsatisfied FSI similarity ratio (un-FSI) model, respectively, are presented in this paper. The PCS storage tank of AP1000 Nuclear Power Engineering, as the study project, is studied by Adina software, and the responses, such as stress, stain, and displacement, etc., of prototype model, FSI model, and un-FSI model are compared. The results provide that when researchers study the rigidity LST dynamic response parameters and vibration characteristics, such as displacement, acceleration and liquid wave height, the tank wall stress response parameters etc., FSI model should be used.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Fuzzy uncertainty modeling applied to AP1000 nuclear power plant LOCA
    Ferreira Guimaraes, Antonio Cesar
    Franklin Lapa, Celso Marcelo
    Lamego Simoes Filho, Francisco Fernando
    Cabral, Denise Cunha
    ANNALS OF NUCLEAR ENERGY, 2011, 38 (08) : 1775 - 1786
  • [22] Numerical simulation of the influence for AP1000 nuclear power plant accident with FLEXPART
    Guo, Jianghua
    Zhu, Yangmo
    Nie, Chu
    Energy Education Science and Technology Part A: Energy Science and Research, 2014, 32 (01): : 667 - 676
  • [23] Numerical simulation and experimental research on CHF characteristics of AP1000 nuclear reactor
    Liu, Jianquan
    Zhang, Jiguo
    Shi, Jingda
    Sun, Baomin
    Ji, Huimin
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2018, 55 (12) : 1412 - 1424
  • [24] The research on AP1000 nuclear main pumps' complete characteristics and the normalization method
    Zhu, Rongsheng
    Liu, Yong
    Wang, Xiuli
    Fu, Qiang
    Yang, Ailing
    Long, Yun
    ANNALS OF NUCLEAR ENERGY, 2017, 99 : 1 - 8
  • [25] Shaking Table Test of Steel Cylindrical Liquid Storage Tank Considering the Roof Characteristics
    Doobyong Bae
    Jang Ho Park
    International Journal of Steel Structures, 2018, 18 : 1167 - 1176
  • [26] Shaking Table Test of Steel Cylindrical Liquid Storage Tank Considering the Roof Characteristics
    Bae, Doobyong
    Park, Jang Ho
    INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2018, 18 (04) : 1167 - 1176
  • [27] Study on mechanical model and shaking table test of spherical tank rolling isolation
    Lyu, Yuan
    Sun, Jiangang
    Li, Zhuohua
    Teng, Jun
    Cui, Lifu
    Cheng, Lihua
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2022, 51 (08): : 1895 - 1917
  • [28] FSI effects and seismic performance evaluation of water storage tank of AP1000 subjected to earthquake loading
    Zhao, Chunfeng
    Chen, Jianyun
    Xu, Qiang
    NUCLEAR ENGINEERING AND DESIGN, 2014, 280 : 372 - 388
  • [29] A Calculation Method for the Sloshing Impact Pressure Imposed on the Roof of a Passive Water Storage Tank of AP1000
    Lu, Daogang
    Zeng, Xiaojia
    Dang, Junjie
    Liu, Yu
    SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2016, 2016
  • [30] The Overview in Safety Review of Human Factors Engineering and Control Room Design in Chinese AP1000 Nuclear Power Plant
    Feng, Yan
    Wang, Zhong-Qiu
    Wu, Qi
    Zhang, Yun-Bo
    Liu, Jing-Bin
    NUCLEAR POWER PLANTS: INNOVATIVE TECHNOLOGIES FOR INSTRUMENTATION AND CONTROL SYSTEMS, 2018, 455 : 131 - 138