Effect of Atrial Septal Defect Shape Evaluated Using Three-Dimensional Transesophageal Echocardiography on Size Measurements for Percutaneous Closure

被引:59
|
作者
Seo, Jeong-Sook [2 ]
Song, Jong-Min [1 ]
Kim, Young-Hak
Park, Duk-Woo
Lee, Seung-Whan
Kim, Won-Jang
Kim, Dae-Hee
Kang, Duk-Hyun
Song, Jae-Kwan
机构
[1] Univ Ulsan, Coll Med, Dept Cardiol, Asan Med Ctr,Div Cardiol, Seoul 138736, South Korea
[2] Inje Univ, Busan Paik Hosp, Dept Cardiol, Pusan, South Korea
关键词
Atrial septal defect; Three-dimensional echocardiography; Percutaneous closure; TRANSCATHETER CLOSURE; MAGNETIC-RESONANCE; PATIENT SELECTION; DEVICE; OCCLUDER; CARDIOSEAL; EXPERIENCE; MORPHOLOGY; OCCLUSION; DOPPLER;
D O I
10.1016/j.echo.2012.07.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The effect of the atrial septal defect (ASD) shape on ASD size measurements remains unclear. We assessed the relationships between the stretched balloon diameter (SBD) and the diameters measured using two-dimensional and three-dimensional (3D) transesophageal echocardiography (TEE) and evaluated the effect of ASD shape on these relationships in patients with secundum ASD. Methods: We prospectively enrolled 107 consecutive patients who underwent transcatheter closure of ASD. The SBDs and ASD diameters on two-dimensional and 3D-TEE were measured. The circular index of the ASD was defined as the ratio of the maximal diameter to the minimal diameter on the 3D-TEE image. All patients were clinically followed up for a median of 1.3 months after the procedure. Results: The correlations and agreements between measurements were significantly better in patients with a round (circular index less than 1.5) than with an oval ASD. The differences between the SBDs and maximal diameter on 3D-TEE images were significantly smaller in patients with a large oval ASD than in the other patients. The differences between the size of the devices finally implanted and maximal diameter on 3D-TEE images were smaller in patients with a large oval than with a round ASD. On multivariate linear regression analysis, a formula of the relationship between the finally selected device size and 3D-TEE parameters was constructed: device size = 0.964 x maximal diameter on 3D-TEE image - 2.622 x circular index + 7.084. No major complications, including device embolization, developed during follow-up. Conclusions: The relationships between the SBDs and maximal diameters measured on two-dimensional and 3D-TEE images are influenced by the ASD shape and size. Therefore, the ASD shape, as well as the size, should be considered when the device size is determined without SBD measurement. (JAm Soc Echocardiogr 2012;25:1031-40.)
引用
收藏
页码:1031 / 1040
页数:10
相关论文
共 50 条
  • [21] Three-dimensional transesophageal echocardiography of the atrial septal defects
    Francisco-Javier Roldán
    Jesús Vargas-Barrón
    Clara Vázquez-Antona
    Luis Muñoz Castellanos
    Julio Erdmenger-Orellana
    Ángel Romero-Cárdenas
    Marco-Antonio Martínez-Ríos
    Cardiovascular Ultrasound, 6
  • [22] Clinical Implications of Real-Time Three-Dimensional Transesophageal Echocardiography for Catheter Closure of Atrial Septal Defect
    Kijima, Yasufumi
    Akagi, Teiji
    Nakagawa, Koji
    Taniguchi, Manabu
    Toh, Norihisa
    Kusano, Kengo
    Sano, Hiroshi Ito Shunji
    AMERICAN JOURNAL OF CARDIOLOGY, 2012, 109 (07): : 99S - 99S
  • [23] Three-Dimensional Transesophageal Echocardiographic Guidance during Retrieval of an Embolized Percutaneous Atrial Septal Defect Closure Device
    Lerakis, Stamatios
    Babaliaros, Vasilis
    Junahadhwalla, Zahid
    Williams, Stephen K.
    Martin, Randolph
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2009, 26 (08): : 970 - 972
  • [24] Assessment of Atrial Septal Defect Anatomy by Real-Time Three-dimensional Transesophageal Echocardiography and Residual Shunting After Transcatheter Atrial Septal Defect Closure
    Johri, Amer M.
    Palacios, Igor F.
    Cubeddu, Roberto J.
    Inglessis, Ignacio
    Passeri, Jonathan
    CIRCULATION, 2009, 120 (18) : S392 - S392
  • [25] Three-Dimensional Transesophageal Echocardiography of Atrial Septal Defect: A Qualitative and Quantitative Anatomic Study
    Roberson, David A.
    Cui, Wei
    Patel, Dhaval
    Tsang, Wendy
    Sugeng, Lissa
    Weinert, Lynn
    Bharati, Saroja
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (06) : 600 - 610
  • [26] Complex Atrial Septal Defect: Percutaneous Repair Guided by Three-Dimensional Echocardiography
    Georgakis, Alexander
    Radtke, Wolfgang A. K.
    Lopez, Christian
    Fiss, David
    Moser, Cathy
    VanDecker, William
    O'Murchu, Brian
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2010, 27 (05): : 590 - 593
  • [27] Multiperforated atrial septal "aneurysm in aneurysm": Percutaneous closure guided by real-time three-dimensional transesophageal echocardiography
    Sun, Feifei
    Fan, Miao
    Li, Ying
    Ren, Weidong
    Chen, Yanli
    JOURNAL OF CLINICAL ULTRASOUND, 2018, 46 (06) : 421 - 423
  • [28] Real-Time Three-Dimensional Transesophageal Echocardiography Is Useful for Percutaneous Closure of Multiple Secundum Atrial Septal Defects
    Zhang, Chun
    Li, Zhian
    Xu, Jin
    HELLENIC JOURNAL OF CARDIOLOGY, 2014, 55 (06) : 486 - 491
  • [29] The relation between atrial septal defect shape, diameter, and area using three-dimensional transoesophageal echocardiography and balloon sizing during percutaneous closure in children
    Hascoet, Sebastien
    Hadeed, Khaled
    Marchal, Pauline
    Dulac, Yves
    Alacoque, Xavier
    Heitz, Francois
    Acar, Philippe
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2015, 16 (07) : 747 - 755
  • [30] Feasibility of real-time three-dimensional transoesophageal echocardiography for guidance of percutaneous atrial septal defect closure
    Lodato, Joseph A.
    Cao, Qi Ling
    Weinert, Lynn
    Sugeng, Lissa
    Lopez, John
    Lang, Roberto M.
    Hijazi, Ziyad M.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (04): : 543 - 548