Liquid water saturation and oxygen transport resistance in polymer electrolyte membrane fuel cell gas diffusion layers

被引:44
|
作者
Muirhead, Daniel [1 ]
Banerjee, Rupak [1 ]
George, Michael G. [1 ]
Ge, Nan [1 ]
Shrestha, Pranay [1 ]
Liu, Hang [1 ]
Lee, Jongmin [1 ]
Bazylak, Aimy [1 ]
机构
[1] Univ Toronto, Dept Mech & Ind Engn, Thermofluids Energy & Adv Mat TEAM Lab, Inst Sustainable Engn,Fac Appl Sci & Engn, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院; 加拿大创新基金会;
关键词
Synchrotron X-ray radiography; Relative humidity; Limiting current density; Condensation; Spatial liquid water distribution; RAY COMPUTED-TOMOGRAPHY; HIGH-CURRENT DENSITY; PLANE POROSITY DISTRIBUTIONS; MICROPOROUS LAYER; SYNCHROTRON RADIOGRAPHY; RELATIVE-HUMIDITY; 2-PHASE TRANSPORT; CATALYST LAYERS; PEMFC GDLS; PERFORMANCE;
D O I
10.1016/j.electacta.2018.04.050
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Liquid water accumulation in the gas diffusion layers (GDLs) of polymer electrolyte membrane (PEM) fuel cells is governed by a complex interplay of factors, the full scope of which is not yet fully established in literature. This study presents the combined effects of relative humidity (RH) and current density on liquid water accumulation and oxygen mass transport resistance in the cathode GDLs of a PEM fuel cell. Through-plane liquid water saturation distributions were measured in situ using synchrotron X-ray radiography while simultaneously performing limiting current-based characterizations of oxygen transport resistance. At low current densities (< 0.5 A.cm(-2)), lower cathode RH levels resulted in the largest oxygen transport resistances due to reductions in ionomer hydration in the catalyst layer. In the intermediate current density range (1.5-2.1 A.cm(-2)), high RH levels resulted in the largest oxygen transport resistances due to the observed significant sensitivity of liquid water accumulation to cathode RH. At high current densities (> 3.0 A.cm(-2)), cathode GDL liquid saturation levels were high regardless of cathode inlet RH, and the oxygen transport resistance was therefore less sensitive to RH. Furthermore, it was established that liquid water tends to preferentially accumulate in regions of higher local porosity within the GDL, identified by combining measured liquid water saturations with micro-computed tomography (mu CT) characterizations of the through-plane porosity profile. Finally, the strong relationship between GDL oxygen transport resistance and liquid water-free (effective) pore space of the GDL was examined in order to consider the feasibility of predicting oxygen transport resistance based on overall liquid saturation. (c) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:250 / 265
页数:16
相关论文
共 50 条
  • [21] Lattice Boltzmann simulations of water transport in gas diffusion layer of a polymer electrolyte membrane fuel cell
    Hao, Liang
    Cheng, Ping
    JOURNAL OF POWER SOURCES, 2010, 195 (12) : 3870 - 3881
  • [22] Liquid water transport in a mixed-wet gas diffusion layer of a polymer electrolyte fuel cell
    Sinha, Puneet K.
    Wang, Chao-Yang
    CHEMICAL ENGINEERING SCIENCE, 2008, 63 (04) : 1081 - 1091
  • [23] Numerical Simulation of Liquid Water Transport in a Multiperforated Gas Diffusion Layer of Polymer Electrolyte Membrane Fuel Cells
    Yin, Bifeng
    Zhang, Xu
    Xu, Sheng
    Xie, Xuan
    Dong, Fei
    JOURNAL OF ENERGY ENGINEERING, 2023, 149 (02)
  • [24] Effect of gas diffusion layer thickness on liquid water transport characteristics in polymer electrolyte membrane fuel cells
    Jeon, Dong Hyup
    JOURNAL OF POWER SOURCES, 2020, 475 (475)
  • [25] Pore-scale parametric sensitivity analysis of liquid water transport in the gas diffusion layer of polymer electrolyte membrane fuel cell
    Lai, Tao
    Qu, Zhiguo
    APPLIED THERMAL ENGINEERING, 2023, 229
  • [26] Experimental dissection of oxygen transport resistance in the components of a polymer electrolyte membrane fuel cell
    Oh, Hwanyeong
    Lee, Yoo Il
    Lee, Guesang
    Min, Kyoungdoug
    Yi, Jung S.
    JOURNAL OF POWER SOURCES, 2017, 345 : 67 - 77
  • [27] Modeling the Liquid Water Transport in the Gas Diffusion Layer for Polymer Electrolyte Membrane Fuel Cells Using a Water Path Network
    Alink, Robert
    Gerteisen, Dietmar
    ENERGIES, 2013, 6 (09): : 4508 - 4530
  • [28] Insights into Oxygen Transport Properties of Partially Saturated Gas Diffusion Layers for Polymer Electrolyte Fuel Cells
    Yoshimune, Wataru
    Yamaguchi, Satoshi
    Kato, Satoru
    ENERGY & FUELS, 2023, 37 (10) : 7424 - 7432
  • [29] Pore-network modeling of liquid water transport in gas diffusion layer of a polymer electrolyte fuel cell
    Sinha, Puneet K.
    Wang, Chao-Yang
    ELECTROCHIMICA ACTA, 2007, 52 (28) : 7936 - 7945
  • [30] Sensitivity Analysis of Mass Transport Properties of Gas Diffusion Layers of Polymer Electrolyte Membrane Fuel Cells
    Tahseen, Siddiq Husain
    Milani, Abbas S.
    Hoorfar, Mina
    PROCEEDINGS OF THE ASME 10TH INTERNATIONAL CONFERENCE ON NANOCHANNELS, MICROCHANNELS AND MINICHANNELS 2012, 2012, : 149 - 155