Instruments for chorionic villus sampling for prenatal diagnosis

被引:6
|
作者
Young, Carmen [1 ]
von Dadelszen, Peter [2 ]
Alfirevic, Zarko [3 ]
机构
[1] Lois Hole Hosp Women, Dept Obstet & Gynaecol, Div Maternal Fetal Med, Edmonton, AB, Canada
[2] Univ British Columbia, Dept Obstet & Gynaecol, Vancouver, BC V5Z 1M9, Canada
[3] Univ Liverpool, Dept Womens & Childrens Hlth, Liverpool L8 7SS, Merseyside, England
关键词
Chorionic Villi Sampling [instrumentation; Suction [instrumentation; Surgical Instruments; Female; Humans; Pregnancy; ASPIRATION; CANNULAS;
D O I
10.1002/14651858.CD000114.pub2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Chorionic villus sampling (CVS) is the method of choice for obtaining fetal tissue for prenatal diagnosis before 15 weeks of pregnancy. CVS can be performed using either a transabdominal or transcervical approach. The type of instrument and technique used could have a significant impact on the outcome of the procedure. An ability to manoeuvre the instrument within the uterine cavity without puncturing the gestational sac, to see the tip of the instrument on ultrasound scanning and to minimise the number of instrument passes into the uterus are particularly important. Objectives To compare the efficacy and safety of different instruments and techniques used to obtain chorionic tissue in early pregnancy by the transabdominal or transcervical route. Primary outcomes included failure to obtain an adequate sample (greater than 5 mg of chorionic villi), need for reinsertion of the instrument, pain, and miscarriage following the procedure. Secondary outcomes included mean weight of tissue obtained, successful culture, difficult instrument insertion, poor visualisation of instrument, vaginal bleeding following the procedure and cost per procedure. Search methods We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 August 2012). Selection criteria Randomised trials comparing different instruments (forceps, cannula, needle) or techniques for CVS using either transabdominal or transcervical approach. Data collection and analysis Two review authors assessed eligibility and trial quality. Main results For transcervical CVS, forceps and cannulae were evaluated in five trials involving 472 women. When a cannula was used, operators failed to obtain an adequate sample (greater than 5 mg of chorionic villi) more often (average risk ratio (RR) 3.81; 95% confidence interval (CI) 1.52 to 9.56). There was no difference in the need for reinsertion of instruments (average RR 2.44; 95% CI 0.83 to 7.20). However, inserting a cannula was more painful (RR 1.93; 95% CI 1.11 to 3.37). There was no difference in spontaneous miscarriage when the use of a cannula was compared with biopsy forceps (RR 1.00; 95% CI 0.14 to 6.96). One study reported the cost of the procedures and found CVS with a cannula to be more expensive (mean difference (MD) $183.7; 95% CI 152.62 to 214.78). When different types of cannulae for transcervical CVS were compared, a Portex cannula was more likely to result in an inadequate sample (RR 2.23; 95% CI 1.25 to 3.98) compared with the silver cannula and to result in a difficult (RR 3.26; 95% CI 1.38 to 7.67) or painful (RR 5.81; 95% CI 1.41 to 23.88) procedure when compared with the aluminium cannula. For transabdominal CVS, two trials comparing different needle techniques were included involving 285 women. One study using an ex vivo system of term placentae was excluded. The included trials compared different continuous negative pressure aspiration techniques with a discontinuous negative pressure system created by a syringe attached to a 20 gauge needle. The studies produced discrepant results. One study found there was no significant difference between groups in the mean weight of chorionic villi obtained (MD 0.40; 95% CI -2.25 to 3.05) or in failure to obtain an adequate sample (more than 5 mg of chorionic villi) on the first attempt (RR 1.02; 95% CI 0.54 to 1.93), whereas the other study found both of these outcomes to be significantly less favourable with the standard discontinuous technique using a syringe (mean weight of chorionic villi obtained: MD -14.80; 95% CI -21.71 to -7.89; failure to obtain an adequate sample on the first attempt: RR 2.73; 95% CI 1.08 to 6.92). There was no difference in rate of miscarriage following the procedure in either study (RR 7.15; 95% CI 0.37 to 136.50; RR 2.93; 95% CI 0.12 to 70.00). Perceived pain by the patient was similar between groups (MD 0.00; 95% CI -0.04 to 0.04) as was success of culture (no failed cases). Authors' conclusions For transcervical CVS, although there is some evidence to support the use of small forceps instead of cannulae, the evidence is not strong enough to support change in practice for clinicians who have become familiar with a particular technique. For transabdominal CVS, based on current evidence, there is no difference in clinically important outcomes with the use of a continuous compared with a discontinuous negative pressure needle aspiration system.
引用
收藏
页数:67
相关论文
共 50 条
  • [11] Chorionic villus sampling in the prenatal diagnosis of placental mesenchymal dysplasia
    Arigita, M.
    Illa, M.
    Nadal, A.
    Badenas, C.
    Soler, A.
    Alsina, N.
    Borrell, A.
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2010, 36 (05) : 644 - 645
  • [12] Chorionic Villus Sampling Complications in Prenatal Diagnosis of Thalassemia Major
    Sani, R. Monzavi
    Savadkuhi, F.
    Rohani, Z.
    [J]. IRANIAN JOURNAL OF RADIOLOGY, 2010, 7 (02) : 101 - 104
  • [13] PRENATAL-DIAGNOSIS OF CYSTINOSIS UTILIZING CHORIONIC VILLUS SAMPLING
    SMITH, ML
    PELLETT, OL
    CASS, MMJ
    KENNAWAY, NG
    BUIST, NRM
    BUCKMASTER, J
    GOLBUS, M
    SPEAR, GS
    SCHNEIDER, JA
    [J]. PRENATAL DIAGNOSIS, 1987, 7 (01) : 23 - 26
  • [14] PRENATAL-DIAGNOSIS - FETAL DEVELOPMENT AFTER CHORIONIC VILLUS SAMPLING
    RODECK, CH
    [J]. LANCET, 1993, 341 (8843): : 468 - 469
  • [15] PRENATAL-DIAGNOSIS BY CHORIONIC VILLUS SAMPLING - EXPERIENCE IN 300 CASES
    HOGGE, WA
    SCHONBERG, SA
    GOLBUS, MS
    [J]. CLINICAL RESEARCH, 1985, 33 (01): : A118 - A118
  • [16] PRENATAL-DIAGNOSIS OF ZELLWEGERS SYNDROME BY CHORIONIC VILLUS SAMPLING AND A CAVEAT
    CAREY, WF
    ROBERTSON, EF
    VANCRUGTEN, C
    POULOS, A
    NELSON, PV
    [J]. PRENATAL DIAGNOSIS, 1986, 6 (03) : 227 - 229
  • [17] PRENATAL-DIAGNOSIS OF TRIPLOIDY BY TRANS-ABDOMINAL CHORIONIC VILLUS SAMPLING
    ZOLOTUKHINA, TV
    KULIEV, AM
    BIRYUKOV, VB
    KIRILLOVA, IA
    [J]. GENETIKA, 1989, 25 (05): : 950 - 952
  • [18] A 26-Year Experience in Chorionic Villus Sampling Prenatal Genetic Diagnosis
    Jorge, Paula
    Mota-Freitas, Maria Manuela
    Santos, Rosario
    Silva, Maria Luz
    Soares, Gabriela
    Fortuna, Ana Maria
    [J]. JOURNAL OF CLINICAL MEDICINE, 2014, 3 (03): : 838 - 848
  • [19] Prenatal diagnosis by chorionic villus sampling in multiple pregnancies prior to fetal reduction
    De Catte, L
    Camus, M
    Bonduelle, M
    Liebaers, I
    Foulon, W
    [J]. AMERICAN JOURNAL OF PERINATOLOGY, 1998, 15 (05) : 339 - 343
  • [20] Chorionic villus sampling for early prenatal diagnosis: Experience at a mainland Chinese hospital
    Han, J.
    Pan, M.
    Zhen, L.
    Yang, X.
    Ou, Y-M.
    Liao, C.
    Li, D-Z.
    [J]. JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2014, 34 (08) : 669 - 672