Comparison of a Stable Isotope-Labeled and an Analog Internal Standard for the Quantification of Everolimus by a Liquid Chromatography-Tandem Mass Spectrometry Method

被引:12
|
作者
Heideloff, Courtney [1 ]
Payto, Drew [1 ]
Wang, Sihe [1 ]
机构
[1] Cleveland Clin, Dept Clin Pathol, Cleveland, OH 44106 USA
关键词
everolimus; everolimus-d4; 32-desmethoxyrapamycin; LC-MS/MS; FLUORESCENCE POLARIZATION IMMUNOASSAY; LC-MS/MS METHOD; WHOLE-BLOOD; ORGAN-TRANSPLANTATION; CYCLOSPORINE-A; SIROLIMUS; TACROLIMUS; PERFORMANCE; PITFALLS;
D O I
10.1097/FTD.0b013e318283403e
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Everolimus is an immunosuppressant drug used in solid organ transplantation. Immunoassays and liquid chromatography-mass spectrometry (LC-MS) methods have been used for therapeutic drug monitoring of this drug. In LC-tandem mass spectrometry (MS/MS) methods, both 32-desmethoxyrapamycin and everolimus-d4 have been used as internal standards. Objectives: To compare 2 internal standards (32-desmethoxyrapamycin and everolimus-d4) for the quantification of everolimus by an LC-MS/MS method. Methods: Both 32-desmethoxyrapamycin and everolimus-d4 were introduced in the method validation process with 2 transitions simultaneously monitored for everolimus (975.6 -> 908.7 as the quantifier and 975.6 -> 926.9 as the qualifier) by an established LC-MS/MS method. The key performance characteristics were lower limit of quantification, accuracy, precision, and comparison with an LC-MS/MS method offered by another laboratory. Results: The lower limit of quantification (LLOQ) was 1.0 ng/mL using either internal standard with an analytical recovery of 98.3%-108.1% across the linear range. The total coefficient of variation for everolimus was 4.3%-7.2% with no significant difference between the 2 internal standards. In comparison with an independent LC-MS/MS method, though everolimus-d4 offered a better slope (0.95 versus 0.83), both internal standards showed acceptable results and had a coefficient of correlation r > 0.98 in the tested concentration range of 1.2-12.7 ng/mL. Conclusions: Although everolimus-d4 offered a more favorable comparison with an independent LC-MS/MS method, both everolimus-d4 and 32-desmethoxyrapamycin had acceptable performance as the internal standards for everolimus quantification by the LC-MS/MS method.
引用
收藏
页码:246 / 250
页数:5
相关论文
共 50 条
  • [41] Quantification of erufosine, the first intravenously applicable alkylphosphocholine, in human plasma by isotope dilution liquid chromatography-tandem mass spectrometry using a deuterated internal standard
    Lindner, Lars H.
    Eibl, Hansjoerg
    Hossann, Martin
    Vogeser, Michael
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 869 (1-2): : 16 - 19
  • [42] Determination of bovine lactoferrin in dairy products by ultra-high performance liquid chromatography-tandem mass spectrometry based on tryptic signature peptides employing an isotope-labeled winged peptide as internal standard
    Zhang, Jingshun
    Lai, Shiyun
    Cai, Zengxuan
    Chen, Qi
    Huang, Baifen
    Ren, Yiping
    ANALYTICA CHIMICA ACTA, 2014, 829 : 33 - 39
  • [43] Method for quantification of opioids and their metabolites in autopsy blood by liquid chromatography-tandem mass spectrometry
    Al-Asmari, Ahmed I.
    Anderson, Robert A.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (07) : 394 - 408
  • [44] Validation of a method for quantification of ketobemidone in human plasma with liquid chromatography-tandem mass spectrometry
    Lampinen, M
    Bondesson, U
    Fredriksson, E
    Hedeland, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 789 (02): : 347 - 354
  • [45] Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma
    Ramakrishna, NVS
    Vishwottam, KN
    Manoj, S
    Koteshwara, M
    Wishu, S
    Varma, DP
    BIOMEDICAL CHROMATOGRAPHY, 2005, 19 (10) : 751 - 760
  • [46] Quantification of Fluoxetine in Human Plasma by the Development of Liquid Chromatography-tandem Mass Spectrometry Method
    Negi, Geeta
    Majeed, Jaseela
    Arora, Saurabh
    Rana, Sachin
    Singh, Manoj
    Tomar, Jaideep
    INDIAN JOURNAL OF PHARMACEUTICAL EDUCATION AND RESEARCH, 2021, 55 (01) : S303 - S311
  • [47] Use of a structural analogue versus a stable isotope labeled internal standard for the quantification of angiotensin IV in rat brain dialysates using nano-liquid chromatography/tandem mass spectrometry
    Lanckmans, Katrien
    Sarre, Sophie
    Smolders, Ilse
    Michotte, Yvette
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (07) : 1187 - 1195
  • [48] Rapid liquid chromatography-tandem mass spectrometry method for quantification of ziprasidone in human plasma
    Al-Dirbashi, OY
    Aboul-Enein, HY
    Al-Odaib, A
    Jacob, M
    Rashed, MS
    BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (04) : 365 - 368
  • [49] A validated method for the quantification of fosfomycin in human plasma by liquid chromatography-tandem mass spectrometry
    Martens-Lobenhoffer, Jens
    Bode-Boeger, Stefanie M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 990 : 164 - 168
  • [50] Validation of a Liquid Chromatography-Tandem Mass Spectrometry Method for Quantification of Glycopyrrolate in Horse Plasma
    Rumpler, M. J.
    Sams, R. A.
    Colahan, P.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (09) : 656 - 664