Comparison of a Stable Isotope-Labeled and an Analog Internal Standard for the Quantification of Everolimus by a Liquid Chromatography-Tandem Mass Spectrometry Method

被引:12
|
作者
Heideloff, Courtney [1 ]
Payto, Drew [1 ]
Wang, Sihe [1 ]
机构
[1] Cleveland Clin, Dept Clin Pathol, Cleveland, OH 44106 USA
关键词
everolimus; everolimus-d4; 32-desmethoxyrapamycin; LC-MS/MS; FLUORESCENCE POLARIZATION IMMUNOASSAY; LC-MS/MS METHOD; WHOLE-BLOOD; ORGAN-TRANSPLANTATION; CYCLOSPORINE-A; SIROLIMUS; TACROLIMUS; PERFORMANCE; PITFALLS;
D O I
10.1097/FTD.0b013e318283403e
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Everolimus is an immunosuppressant drug used in solid organ transplantation. Immunoassays and liquid chromatography-mass spectrometry (LC-MS) methods have been used for therapeutic drug monitoring of this drug. In LC-tandem mass spectrometry (MS/MS) methods, both 32-desmethoxyrapamycin and everolimus-d4 have been used as internal standards. Objectives: To compare 2 internal standards (32-desmethoxyrapamycin and everolimus-d4) for the quantification of everolimus by an LC-MS/MS method. Methods: Both 32-desmethoxyrapamycin and everolimus-d4 were introduced in the method validation process with 2 transitions simultaneously monitored for everolimus (975.6 -> 908.7 as the quantifier and 975.6 -> 926.9 as the qualifier) by an established LC-MS/MS method. The key performance characteristics were lower limit of quantification, accuracy, precision, and comparison with an LC-MS/MS method offered by another laboratory. Results: The lower limit of quantification (LLOQ) was 1.0 ng/mL using either internal standard with an analytical recovery of 98.3%-108.1% across the linear range. The total coefficient of variation for everolimus was 4.3%-7.2% with no significant difference between the 2 internal standards. In comparison with an independent LC-MS/MS method, though everolimus-d4 offered a better slope (0.95 versus 0.83), both internal standards showed acceptable results and had a coefficient of correlation r > 0.98 in the tested concentration range of 1.2-12.7 ng/mL. Conclusions: Although everolimus-d4 offered a more favorable comparison with an independent LC-MS/MS method, both everolimus-d4 and 32-desmethoxyrapamycin had acceptable performance as the internal standards for everolimus quantification by the LC-MS/MS method.
引用
收藏
页码:246 / 250
页数:5
相关论文
共 50 条
  • [1] Micromethod for Quantification of Cinacalcet in Human Plasma by Liquid Chromatography-Tandem Mass Spectrometry Using a Stable Isotope-Labeled Internal Standard
    Cangemi, Giuliana
    Barco, Sebastiano
    Verrina, Enrico E.
    Scurati, Samuele
    Melioli, Giovanni
    Alberighi, Ornella Della Casa
    THERAPEUTIC DRUG MONITORING, 2013, 35 (01) : 112 - 117
  • [2] Using a stable isotope-labeled internal standard for liquid chromatography-tandem mass spectrometry quantitation of meloxicam in human plasma
    Zhan, Cuijiao
    Wang, Changmao
    Wang, Yaqin
    Xie, Haitang
    Chu, Jiru
    Zhang, Rong
    Hu, Rongfeng
    Shen, Jie
    Jia, Yuanwei
    BIOMEDICAL CHROMATOGRAPHY, 2021, 35 (12)
  • [3] Quantification of carbohydrates in human serum using gas chromatography-mass spectrometry with the stable isotope-labeled internal standard method
    Zhang, Ming-Jia
    Zhao, Jin-Hui
    Tang, Ying-Shu
    Meng, Fan-Yu
    Gao, Si-Qi
    Han, Su
    Hou, Shao-Ying
    Liu, Li-Yan
    NEW JOURNAL OF CHEMISTRY, 2022, 46 (23) : 11357 - 11367
  • [4] Determination of egg and milk allergen in food products by liquid chromatography-tandem mass spectrometry based on signature peptides and isotope-labeled internal standard
    Sufang Fan
    Junmei Ma
    Zhuo Liu
    Yawei Ning
    Meicong Cao
    Qiang Li
    Yan Zhang
    FoodScienceandHumanWellness, 2023, 12 (03) : 728 - 736
  • [5] Determination of egg and milk allergen in food products by liquid chromatography-tandem mass spectrometry based on signature peptides and isotope-labeled internal standard
    Fan, Sufang
    Ma, Junmei
    Liu, Zhuo
    Ning, Yawei
    Cao, Meicong
    Li, Qiang
    Zhang, Yan
    FOOD SCIENCE AND HUMAN WELLNESS, 2023, 12 (03) : 728 - 736
  • [6] Liquid chromatography tandem mass spectrometry method for determination of N-acetylcysteine in human plasma using an isotope-labeled internal standard
    Lu, Chuan
    Liu, Gangyi
    Jia, Jingying
    Gui, Yuzhou
    Liu, Yanmei
    Zhang, Mengqi
    Liu, Yun
    Li, Shuijun
    Yu, Chen
    BIOMEDICAL CHROMATOGRAPHY, 2011, 25 (04) : 427 - 431
  • [7] Investigation of variability in the matrix effect on stable isotope-labeled internal standards in liquid chromatography-tandem mass spectrometry analysis of 25 pesticides in vegetables
    Banno, Arisa
    Yabuki, Yoshinori
    Sonoda, Motohiro
    Tanimori, Shinji
    JOURNAL OF PESTICIDE SCIENCE, 2024, 49 (02) : 65 - 76
  • [8] Simultaneous Relative Quantification of Various Polyglycerophospholipids with Isotope-Labeled Methylation by Nanoflow Ultrahigh Performance Liquid Chromatography-Tandem Mass Spectrometry
    Lee, Jong Cheol
    Yang, Joon Seon
    Moong, Myeong Hee
    ANALYTICAL CHEMISTRY, 2019, 91 (10) : 6716 - 6723
  • [9] Probing dietary triacylglycerol metabolism and meibogenesis in mice: A stable isotope-labeled tracer liquid chromatography-tandem mass spectrometry study
    Butovich, Igor A.
    Yuksel, Seher
    Wilkerson, Amber
    JOURNAL OF BIOLOGICAL CHEMISTRY, 2023, 299 (04)
  • [10] Determination of Lactoferrin in Camel Milk by Ultrahigh-Performance Liquid Chromatography-Tandem Mass Spectrometry Using an Isotope-Labeled Winged Peptide as Internal Standard
    Li, Xia
    Li, Zengmei
    Xu, Enmin
    Chen, Ling
    Feng, Hua
    Chen, Lu
    Deng, Ligang
    Guo, Dongliang
    MOLECULES, 2019, 24 (22):