A Simple Method for Aerosol Transport Efficiency Tests in Sampling Tubes

被引:6
|
作者
Wang, Shibo [1 ]
Kuo, Yu-Mei [2 ]
Lin, Chih-Wei [1 ]
Huang, Sheng-Hsiu [1 ]
Fu, Bin [3 ]
Zhang, Qianxuan [3 ]
Chen, Chih-Chieh [1 ]
机构
[1] Natl Taiwan Univ, Inst Environm & Occupat Hlth Sci, Taipei 10020, Taiwan
[2] Chung Hwa Med Univ, Dept Occupat Safety & Hlth, Tainan 71703, Taiwan
[3] Beijing SDL Technol Co Ltd, Beijing 102206, Peoples R China
关键词
Aerosol sampling; Method development; Particle transport efficiency; Sampling tube design; Reynolds number; AERODYNAMIC PARTICLE SIZER; CHARGED-PARTICLES; DEPOSITION; PENETRATION; DIFFUSION; FLOWS; MODEL;
D O I
10.4209/aaqr.220219
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To obtain representative data, particle loss in sampling tubes must be minimal; otherwise, the magnitude of the losses must be known so it can be corrected. Since particle loss in sample tubes occurs through various mechanisms and depends on particle size, airflow velocity, and Reynolds number, there is no simple method to predict the particle loss of multitudinous configurations of sampling tubes. This study aims to present a simple method for experimentally determining particle loss as a function of particle sizes. Moreover, the applicability of existing models is verified experimentally.An ultrasonic atomizing nozzle was used to generate micrometer-sized polydispersed particles as challenge aerosols. Following charge neutralization, the particle size distribution and number concentration upstream and downstream of the sampling tubes are measured by an Aerodynamic Particle Sizer. The particle loss in the sampling tubes with inner diameters of 4.5, 7.7, and 10 mm are measured at various values of Re (500-5000) and the tube orientations (horizontal and vertical). Both the horizontal and vertical tubes have the lowest loss at a Re of approximately 2100. Gravitational settling and turbulent-induced inertial impaction are the main deposition mechanisms in aerosol transport for particles large than 1 mu m. Gravity plays a significant role when the Re is less than 5000, then its dominant position is gradually replaced by turbulence with the Re continuing to increase. Further, the transport efficiency increased with increasing tube diameter. Consequently, each sampling tube needs to be tested according to the methods mentioned in this study to fully grasp the transport efficiency of particles through the sampling tube.
引用
下载
收藏
页数:14
相关论文
共 50 条
  • [31] Simple method tests cables
    Keith, J
    EDN, 2002, 47 (23) : 106 - 106
  • [32] FILTRATION EFFICIENCY OF ORGANIC VAPOR SAMPLING TUBES AGAINST PARTICULATES
    FAIRCHILD, CI
    TILLERY, MI
    AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1977, 38 (06): : 277 - 283
  • [33] LEAD AEROSOL COLLECTION STUDIES USING SOLID SORBENT PACKED SAMPLING TUBES
    BETZ, LR
    GROB, RL
    ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1984, 17 (08): : 701 - 734
  • [34] Aerosol particle losses in the sampling tubes of nuclear facilities: Assessment and experimental determination
    Vogl, K., 1600, Publ by Pergamon Press Inc, Tarrytown, NY, United States (25):
  • [35] Simple tests for validity when sampling thermodynamic ensembles
    Shirts, Michael R.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2012, 244
  • [36] Entry efficiency of an annular aerosol sampling slot in calm air
    Roger, F.
    Fabries, J.F.
    Gorner, P.
    Wrobel, R.
    Renoux, A.
    Journal of Aerosol Science, 1999, 30 (Suppl. 1)
  • [37] AEROSOL GENERATOR FOR SAMPLING EFFICIENCY DETERMINATIONS UNDER FIELD CONDITIONS
    OESEBURG, F
    BENSCHOP, FM
    JOURNAL OF AEROSOL SCIENCE, 1991, 22 (02) : 159 - 180
  • [38] A simple method of transport parameter estimation for slug injecting tracer tests in porous media
    Liang, Xiuyu
    Zhan, Hongbin
    Liu, Jin
    Dong, Guiming
    Zhang, You-Kuan
    SCIENCE OF THE TOTAL ENVIRONMENT, 2018, 644 : 1536 - 1546
  • [39] Some simple tests of physical efficiency.
    Flack, M
    LANCET, 1919, 1 : 210 - 212
  • [40] A simple, reliable method for the determination of chlorinated volatile organics in human breath and air using glass sampling tubes
    Stein, VB
    Narang, RS
    Wilson, L
    Aldous, KM
    JOURNAL OF ANALYTICAL TOXICOLOGY, 1996, 20 (03) : 145 - 150