Thermal performance analysis of a new refrigerant-heated radiator coupled with air-source heat pump heating system

被引:40
|
作者
Shao, Suola [1 ]
Zhang, Huan [1 ,2 ]
You, Shijun [1 ,2 ]
Zheng, Wandong [1 ,2 ]
Jiang, Lingfei [1 ]
机构
[1] Tianjin Univ, Sch Environm Sci & Engn, Haihe Educ Area, Tianjin 300350, Peoples R China
[2] Tianjin Univ, Minist Educ China, Key Lab Efficient Utilizat Low & Medium Grade Ene, Tianjin 300350, Peoples R China
基金
美国国家科学基金会;
关键词
Refrigerant-heated radiator; Air-source heat pump; Thermal performance; Indoor thermal comfort;
D O I
10.1016/j.apenergy.2019.04.032
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Air-source heat pump (ASHP) is considered to be one of the most energy conservation heating system in the areas without district heating. To improve the performance of the ASHP heating system, a new type of refrigerant heated radiator (RHR) is proposed. As a new direct-condensation terminal, it avoids the secondary heat exchange and is conducive to reduce the condensing temperature and heat loss. Experiments are conducted to investigate the temperature and operating characteristics of the heating system with the new radiator, as well as the thermal performance and system efficiency during the heating period. The results indicate that the radiator has favorable thermal performance with the heat flux varies from 89.2 W/m(2) to 211.4 W/m(2) during the testing period. Heat storage material is employed in the radiator to maintain the stability of indoor thermal environment during the defrosting process, and it can provide the heat of 750.9-1699.6 kJ. The convective heat transfer coefficient of the RHR was regressed and the coefficient of performance (COP) of the new system could be as high as 3.5 during the tests. Meanwhile, the ASHP heating system with RHR is superior in the indoor thermal comfort with the reasonable indoor PMV and lower vertical temperature gradient. It is demonstrated that the refrigerant-heated radiator matches well with the heat pump heating system, and can effectively improve the thermal performance and indoor thermal environment, as well as it has significant effects on the application of ASHP in the severe cold areas.
引用
收藏
页码:78 / 88
页数:11
相关论文
共 50 条
  • [41] Performance analysis of an air-source heat pump using an immersed water condenser
    Ji J.
    Fu H.
    He H.
    Pei G.
    Frontiers of Energy and Power Engineering in China, 2010, 4 (2): : 234 - 245
  • [42] Analysis of Air-Source Heat Pump System Based on Energy Storage for Defrosting
    Liu, Xuelai
    Zhang, Hongrui
    Wang, Lei
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [43] The collocation method of supplementary heat source of air-source heat pump system for space heating based on the MEBPT calculation
    Wu, Zhenjing
    Zhang, Huan
    You, Shijun
    Zheng, Wandong
    Guo, Jin
    PROCEEDINGS OF THE 9TH INTERNATIONAL CONFERENCE ON APPLIED ENERGY, 2017, 142 : 1427 - 1433
  • [44] Capacity optimisation and multi-dimensional analysis of air-source heat pump heating system: A case study
    Liu, Ziyang
    He, Mingfei
    Tang, Xiaoping
    Yuan, Guofeng
    Yang, Bin
    Yu, Xiaohui
    Wang, Zhifeng
    ENERGY, 2024, 294
  • [45] Simulation of Air Source Heat Pump with Refrigerant Injection for Heating Operation
    Liu Haibo
    Shao Shuangquan
    Ma Guoyuan
    Fan Boyuan
    TransactionsofNanjingUniversityofAeronauticsandAstronautics, 2018, 35 (05) : 739 - 748
  • [46] Research on the Flexible Heating Model of an Air-Source Heat Pump System in Nursery Pig Houses
    Wang, Hua
    Liu, Jijun
    Wu, Zhonghong
    Liu, Jia
    Yi, Lu
    Li, Yixue
    Li, Siqi
    Wang, Meizhi
    AGRICULTURE-BASEL, 2023, 13 (05):
  • [47] Performance analysis of combined cooling heating and power (CCHP) exhaust waste heat coupled air source heat pump system
    Hong, Wenpeng
    Hao, Jing
    Wang, Jiayu
    Teng, Da
    Jin, Xu
    BUILDING SIMULATION, 2019, 12 (04) : 563 - 571
  • [48] Performance analysis of combined cooling heating and power (CCHP) exhaust waste heat coupled air source heat pump system
    Wenpeng Hong
    Jing Hao
    Jiayu Wang
    Da Teng
    Xu Jin
    Building Simulation, 2019, 12 : 563 - 571
  • [49] New ideas on defrosting control of air-source heat pump
    Huang, XW
    Wang, RX
    Li, DY
    2ND ASIAN CONFERENCE ON REFRIGERATION AND AIR-CONDITIONING, PROCEEDINGS: NEW CONTRIBUTION TO ASIAN SUSTAINABLE DEVELOPMENT, 2004, : 124 - 132
  • [50] Heating performance analysis of flash tank vapor injection air-source heat pump with a single cylinder rotary compressor
    Zhu, Dongsheng
    Sun, Jinfei
    Yin, Yingde
    Li, Xiuzhen
    Tu, Aimin
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2019, 40 (08): : 2306 - 2313