Three Axis Fluxgate Magnetometer Array Calibration Using Nonmagnetic Rotation Platform

被引:5
|
作者
Pang, Hongfeng [1 ]
Chen, Dixiang [1 ]
Pan, Mengchun [1 ]
Zhang, Qi [1 ]
Luo, Shitu [1 ]
Li, Ji [1 ]
Luo, Feilu [1 ]
机构
[1] Natl Univ Def Technol, Coll Mechatron Engn & Automat, Changsha 410073, Hunan, Peoples R China
关键词
Fluxgate Magnetometer Array; Misalignment Calibration; Nonmagnetic Rotation Platform; Rotation Around Axis; Generality Test; Ferromagnetic Object; SENSOR; TRACKING; COMPASS;
D O I
10.1166/sl.2013.2984
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Three axis fluxgate magnetometer array can be powerful instruments in magnetic mapping and ferromagnetic object localization. The major errors of magnetometer array are caused by sensor triplet deviations (mutual misalignment). A magnetometer array connected by a cross aluminium frame is designed, which contains four three-axis DM-050 fluxgate magnetometers. A convenient array calibration method is presented by rotating a nonmagnetic rotation platform around its axis, and triplet deviations can be estimated. The horizontal deployment of rotation platform is not strictly, and the rotation angle is not strictly required. The generality of computed triplet deviations is tested when the array is deployed with random attitudes. Experimental results show that RMS error of misalignment has been decreased from 802.216 nT to 9.065 nT. In addition, a ferromagnetic object with the size of 15 mm x 75 mm x 55 mm is detected by the calibrated array, and its position is obtained accurately in 3D. It suggests a convenient and effective way for the calibration of three axis fluxgate magnetometer array.
引用
收藏
页码:1420 / 1425
页数:6
相关论文
共 50 条
  • [31] Calibration of Low-Cost Three Axis Magnetometer with Differential Evolution
    Kuncar, Ales
    Sysel, Martin
    Urbanek, Tomas
    CYBERNETICS AND MATHEMATICS APPLICATIONS IN INTELLIGENT SYSTEMS, CSOC2017, VOL 2, 2017, 574 : 120 - 130
  • [32] Calibration of Integral Magnetometer Linear Model Coefficients Using Simultaneous Measurements of a Three-Axis Gyro
    Vasilyuk N.N.
    Gyroscopy and Navigation, 2019, 10 (2) : 99 - 110
  • [33] Attitude-independent geomagnetic navigation using onboard complete three-axis magnetometer calibration
    Huang, Lin
    Jing, Wuxing
    2008 IEEE AEROSPACE CONFERENCE, VOLS 1-9, 2008, : 2552 - 2558
  • [34] Absolute calibration of a three-axis SQUID-cascade vector magnetometer
    Schoenau, T.
    Zakosarenko, V.
    Schmelz, M.
    Stolz, R.
    Anders, S.
    Linzen, S.
    Meyer, M.
    Fassbinder, J. W. E.
    Meyer, H-G
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (01)
  • [35] A real-time calibration method of magnetometer array?s misalignment errors with ac modulated three-axis coil
    Xu, Yushu
    Wang, Yao
    Bian, Leixiang
    Han, Songtong
    Luo, ChaoPeng
    Jiang, Hejun
    MEASUREMENT, 2022, 199
  • [36] Constrained Total Least Squares Algorithm Applied to Three-axis Magnetometer Calibration
    Wu, Zhitian
    Hu, Xiaoping
    Wu, Meiping
    ADVANCES IN MECHATRONICS AND CONTROL ENGINEERING, PTS 1-3, 2013, 278-280 : 968 - 973
  • [37] A Hybrid Calibration Method for a Three-Axis Magnetometer in Limited-Range Attitudes
    Liu, Jianguo
    Yan, Youyu
    Yan, Shenggang
    Li, Xiangang
    IEEE SENSORS JOURNAL, 2022, 22 (01) : 203 - 210
  • [38] Real-time attitude-independent three-axis magnetometer calibration
    Crassidis, JL
    Lai, KL
    Harman, RR
    JOURNAL OF GUIDANCE CONTROL AND DYNAMICS, 2005, 28 (01) : 115 - 120
  • [39] Error calibration of three axis magnetometer based on Global Artificial Fish Swarm Algorithm
    Gong Xiaowen
    Song Zhongguo
    Xi Xiaoli
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [40] Ground based modeling and real time On-board calibration of a three axis magnetometer
    Prasad, Nishanth K.
    Kumar, Saroj
    Dasiga, Sankar
    Ravindra, H. S.
    Maji, Amit
    2014 IEEE AEROSPACE CONFERENCE, 2014,