A Brain-Machine Interface for Control of Medically-Induced Coma

被引:31
|
作者
Shanechi, Maryam M. [1 ,2 ]
Chemali, Jessica J. [3 ]
Liberman, Max [3 ]
Solt, Ken [3 ]
Brown, Emery N. [3 ,4 ,5 ]
机构
[1] Cornell Univ, Sch Elect & Comp Engn, Ithaca, NY 14850 USA
[2] Univ Calif Berkeley, Dept Elect Engn & Comp Sci, Berkeley, CA 94720 USA
[3] Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
[4] MIT, Inst Med Engn & Sci, Cambridge, MA 02139 USA
[5] MIT, Dept Brain & Cognit Sci, Cambridge, MA 02139 USA
基金
美国国家卫生研究院;
关键词
CLOSED-LOOP CONTROL; MODEL-PREDICTIVE CONTROL; DELIVERY-SYSTEM CLADS(TM); QUANTITATIVE EEG ANALYSIS; BISPECTRAL INDEX; BURST-SUPPRESSION; PERFORMANCE ASSESSMENT; PROPOFOL ANESTHESIA; FEEDBACK-CONTROL; GENERAL-ANESTHESIA;
D O I
10.1371/journal.pcbi.1003284
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Medically-induced coma is a drug-induced state of profound brain inactivation and unconsciousness used to treat refractory intracranial hypertension and to manage treatment-resistant epilepsy. The state of coma is achieved by continually monitoring the patient's brain activity with an electroencephalogram (EEG) and manually titrating the anesthetic infusion rate to maintain a specified level of burst suppression, an EEG marker of profound brain inactivation in which bursts of electrical activity alternate with periods of quiescence or suppression. The medical coma is often required for several days. A more rational approach would be to implement a brain-machine interface (BMI) that monitors the EEG and adjusts the anesthetic infusion rate in real time to maintain the specified target level of burst suppression. We used a stochastic control framework to develop a BMI to control medically-induced coma in a rodent model. The BMI controlled an EEG-guided closed-loop infusion of the anesthetic propofol to maintain precisely specified dynamic target levels of burst suppression. We used as the control signal the burst suppression probability (BSP), the brain's instantaneous probability of being in the suppressed state. We characterized the EEG response to propofol using a two-dimensional linear compartment model and estimated the model parameters specific to each animal prior to initiating control. We derived a recursive Bayesian binary filter algorithm to compute the BSP from the EEG and controllers using a linear-quadratic-regulator and a model-predictive control strategy. Both controllers used the estimated BSP as feedback. The BMI accurately controlled burst suppression in individual rodents across dynamic target trajectories, and enabled prompt transitions between target levels while avoiding both undershoot and overshoot. The median performance error for the BMI was 3.6%, the median bias was -1.4% and the overall posterior probability of reliable control was 1 (95% Bayesian credibility interval of [0.87, 1.0]). A BMI can maintain reliable and accurate real-time control of medically-induced coma in a rodent model suggesting this strategy could be applied in patient care.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] A Brain-Machine Interface for Control of Burst Suppression in Medical Coma
    Shanechi, Maryam M.
    Chemali, Jessica J.
    Liberman, Max
    Solt, Ken
    Brown, Emery N.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1575 - 1578
  • [2] An Adaptive Brain-Machine Interface Algorithm for Control of Burst Suppression in Medical Coma
    Yang, Yuxiao
    Shanechi, Maryam M.
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 1638 - 1641
  • [3] Brain-Machine Interface Control Algorithms
    Shanechi, Maryam M.
    IEEE TRANSACTIONS ON NEURAL SYSTEMS AND REHABILITATION ENGINEERING, 2017, 25 (10) : 1725 - 1734
  • [4] CONTROL OF BURST-SUPPRESSION IN A RODENT MODEL OF MEDICAL COMA USING A BRAIN-MACHINE INTERFACE
    Shanechi, M.
    Chemali, J.
    Liberman, M.
    Solt, K.
    Brown, E. N.
    ANESTHESIA AND ANALGESIA, 2014, 118 : S319 - S319
  • [5] Design, Implementation, and Evaluation of a Physiological Closed-loop Control Device for Medically-induced Coma
    An, Jingzhi
    Purdon, Patrick L.
    Solt, Ken
    Sims, Nathaniel M.
    Brown, Emery N.
    Westover, M. Brandon
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 4313 - 4316
  • [6] Brain-machine interface
    Nair, Prashant
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2013, 110 (46) : 18343 - 18343
  • [7] Subcortical ensemble recordings for the control of a brain-machine interface
    Clayton, Daniel A.
    Hanson, Timothy
    Nicolelis, Miguel A. L.
    Turner, Dennis A.
    NEUROSURGERY, 2007, 61 (01) : 212 - 212
  • [8] Brain-machine interface control via reinforcement learning
    DiGiovanna, Jack
    Mahmoudi, Babak
    Mitzelfelt, Jeremiah
    Sanchez, Justin C.
    Principe, Jose C.
    2007 3RD INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, VOLS 1 AND 2, 2007, : 530 - +
  • [9] Neurorehabilitation with brain-machine interface
    Shindo, Keiichiro
    Ushiba, Junichi
    Liu, Meigen
    NEUROSCIENCE RESEARCH, 2010, 68 : E45 - E45
  • [10] Brain-Machine Interface Systems
    Trajkovic, Ljiljana
    IEEE SYSTEMS MAN AND CYBERNETICS MAGAZINE, 2020, 6 (03): : 4 - 8