CBCT Iterative Image Reconstruction Method Using Energy Spectrum Information for Adaptive Proton Therapy

被引:0
|
作者
Yamaguchi, Takashi [1 ]
机构
[1] Sumitomo Heavy Ind Ltd, Yokosuka, Kanagawa, Japan
关键词
TRANSMISSION;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Cone-beam computed tomography (CBCT) is used to determine a patient's position in proton therapy. Its image quality is low compared to that of a conventional CT because data measured by a two-dimensional detector used in CBCT contain scattered X-ray components. Correcting for scattered X-rays using the Klein-Nishina's formula can improve CBCT image quality, but the formula requires the atomic number and atomic number density of substances. In this work, I developed a photon-counting image reconstruction method for estimating the atomic number Z and atomic number density N using the energy information of X-rays. In this study, NZ and Z(4) were calculated as variables in consideration of the convergence of the optimization algorithm. I applied the developed method to an X-ray energy spectrum of a gantry-mounted CBCT, which was simulated with a Monte Carlo simulation code. The result was possible to distinguish soft tissues from water in the simulated object, which was not possible without the energy information. An atomic number and number density obtained with our method allow calculating the stopping power of protons more accurately, which can contribute to improving dose calculation accuracy.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Simultaneous deblurring and iterative reconstruction of CBCT for image guided brain radiosurgery
    Hashemi, SayedMasoud
    Song, William Y.
    Sahgal, Arjun
    Lee, Young
    Huynh, Christopher
    Grouza, Vladimir
    Nordstrom, Hakan
    Eriksson, Markus
    Dorenlot, Antoine
    Regis, Jean Marie
    Mainprize, James G.
    Ruschin, Mark
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (07): : 2521 - 2541
  • [22] Deblurring in Iterative Reconstruction of Half CBCT for Image Guided Brain Radiosurgery
    Hashemi, SayedMasoud
    Lee, Young
    Eriksson, Markus
    Nordstrom, Hakan
    Song, Bongyong
    Nam, Wooseok
    Sahgal, Arjun
    Song, William
    Ruschin, Mark
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [23] Dual energy and iterative CBCT reconstruction allows reducing patient dose
    Gilles, M.
    Benoit, D.
    Bert, J.
    Iborra, A.
    Schick, U.
    Pradier, O.
    Fayad, H.
    Boussion, N.
    Visvikis, D.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S533 - S533
  • [24] Clinical Analysis of a Dual-Energy CT Joint Statistical Image Reconstruction Method in Proton Therapy
    Chen, X.
    Medrano, M.
    Ge, T.
    Liao, R.
    Politte, D.
    Whiting, B.
    Hao, Y.
    Williamson, J.
    O'Sullivan, J.
    Zhao, T.
    MEDICAL PHYSICS, 2022, 49 (06) : E806 - E806
  • [25] Improvement in Image Quality of Low Dose De-CBCT Scans Using Iterative Reconstruction Algorithms
    Georgesen, M. C.
    Keeler, A.
    Roeske, J. C.
    Luce, J. P.
    Kang, H.
    MEDICAL PHYSICS, 2024, 51 (10) : 7721 - 7721
  • [26] Statistical Iterative CBCT Reconstruction Using Convolutional Neural Network
    Gong, Z.
    Shi, Q.
    Liu, L.
    Wang, J.
    Tan, S.
    MEDICAL PHYSICS, 2017, 44 (06)
  • [27] Iterative Adaptive Spectrum Reconstruction Algorithm for MIMO SAR
    Zhou, Wei
    Xie, Wei
    Cao, Xuesong
    Wu, Chao
    Zhu, Shiping
    PROCEEDINGS OF 2016 IEEE 13TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING (ICSP 2016), 2016, : 187 - 191
  • [28] Low-Dose CBCT by Iterative Image Reconstruction Using NonLocal Edge-Preserving Prior
    Wang, J.
    Ouyang, L.
    Lu, W.
    Solberg, T.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [29] Image quality of multiplanar reconstruction of pulmonary CT scans using adaptive statistical iterative reconstruction
    Honda, O.
    Yanagawa, M.
    Inoue, A.
    Kikuyama, A.
    Yoshida, S.
    Sumikawa, H.
    Tobino, K.
    Koyama, M.
    Tomiyama, N.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1000): : 335 - 341
  • [30] Image reconstruction for electrical capacitance tomography by using soft-thresholding iterative method with adaptive regulation parameter
    Dong, Xiangyuan
    Ye, Zhuoyi
    Soleimani, Manuchehr
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (08)