Synchronous detection of glutathione/hydrogen peroxide for monitoring redox status in vivo with a ratiometric upconverting nanoprobe

被引:58
|
作者
Zheng, Judun [1 ,2 ,3 ]
Wu, Yunxia [1 ,2 ,3 ]
Xing, Da [1 ,2 ,3 ]
Zhang, Tao [1 ,2 ,3 ]
机构
[1] South China Normal Univ, MOE Key Lab Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
[2] South China Normal Univ, Inst Laser Life Sci, Guangzhou 510631, Guangdong, Peoples R China
[3] South China Normal Univ, Coll Biophoton, Guangzhou 510631, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
redox status; glutathione; hydrogen peroxide; upconversion imaging; nanoprobe; UP-CONVERSION NANOPARTICLES; REVERSIBLE FLUORESCENT-PROBE; THIOLS REDUCING REPAIR; H2O2 OXIDATIVE STRESS; REAL-TIME; SELECTIVE DETECTION; INTRACELLULAR PH; CANCER-CELLS; LONG-TERM; PEROXYNITRITE;
D O I
10.1007/s12274-019-2327-6
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cellular redox status presents broad implications with diverse physiological and pathological processes. Simultaneous detection of both the oxidative and reductive species of redox couples, especially the most representative pair glutathione/hydrogen peroxide (GSH/H2O2), is crucial to accurately map the cellular redox status. However, it still remains challenging to synchronously detect GSH/H(2)O(2)in vivo due to lack of a reliable measuring tool. Herein, a ratiometric nanoprobe (UCNP-TB) possessing simultaneous delectability of GSH/H2O2 is established based on a multi-spectral upconverting nanophosphor (UCNP-OA) as the luminescence resonance energy transfer (LRET) donor and two dye molecules as the acceptors, including a GSH-sensitive dye (TCG) and a H2O2-sensitive dye (BCH). With the as-prepared UCNP-TB, real-time and synchronous monitoring the variation of GSH and H(2)O(2)in vitro and in living mice can be achieved using the ratio of the upconversion luminescence (UCL) at 540 and 650 nm to that at 800 nm as the detection signal, respectively, providing highly inherent reliability of the sensing results by self-calibration. Moreover, the nanoprobe is capable of mapping the redox status within the drug-resistant tumor and the drug-induced hepatotoxic liver via ratiometric UCL imaging. Thus, this nanoprobe would provide a reliable tool to elucidate the redox state in vivo.
引用
收藏
页码:931 / 938
页数:8
相关论文
共 50 条
  • [41] Effects of ochratoxin a on some production traits, lipid peroxide and glutathione redox status of weaned piglets
    Balogh, K.
    Hausenblasz, J.
    Weber, Maria
    Erdelyi, Marta
    Fodor, Judit
    Mezes, M.
    ACTA VETERINARIA HUNGARICA, 2007, 55 (04) : 463 - 470
  • [42] Ratiometric fluorescent probe with AIE property for monitoring endogenous hydrogen peroxide in macrophages and cancer cells
    Liu, Yong
    Nie, Jing
    Niu, Jie
    Meng, Fangfang
    Lin, Weiying
    SCIENTIFIC REPORTS, 2017, 7
  • [43] Investigation of lipid peroxide and glutathione redox status of chicken conserning on high dietary selenium intake
    Balogh, K.
    Weber, Maria
    Erdelyi, Marta
    Mezes, M.
    ACTA BIOLOGICA HUNGARICA, 2007, 58 (03): : 269 - 279
  • [44] Investigation of Lipid Peroxide and Glutathione Redox Status of Chicken Conserning on High Dietary Selenium Intake
    K. Balogh
    Mária Weber
    Márta Erdélyi
    M. Mézes
    Acta Biologica Hungarica, 2007, 58 : 269 - 279
  • [45] Recent Development of a Fluorescent Probe for In Vivo Detection of Hydrogen Peroxide
    Saha, Subrata Kumar
    Saha, Uday Chand
    INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2020, 10 (05): : L196 - L203
  • [46] Toward in vivo detection of hydrogen peroxide with ultrasound molecular imaging
    Olson, Emilia S.
    Orozco, Jahir
    Wu, Zhe
    Malone, Christopher D.
    Yi, Boemha
    Gao, Wei
    Eghtedari, Mohammad
    Wang, Joseph
    Mattrey, Robert F.
    BIOMATERIALS, 2013, 34 (35) : 8918 - 8924
  • [47] ROLES OF CATALASE AND THE GLUTATHIONE REDOX CYCLE IN THE REGULATION OF ANTERIOR-CHAMBER HYDROGEN-PEROXIDE
    COSTARIDES, AP
    RILEY, MV
    GREEN, K
    OPHTHALMIC RESEARCH, 1991, 23 (05) : 284 - 294
  • [48] Dynamic-Reversible Photoacoustic Probe for Continuous Ratiometric Sensing and Imaging of Redox Status in Vivo
    Zheng, Judun
    Zeng, Qin
    Zhang, Ruijing
    Xing, Da
    Zhang, Tao
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2019, 141 (49) : 19226 - 19230
  • [49] Ratiometric fluorescent probe with AIE property for monitoring endogenous hydrogen peroxide in macrophages and cancer cells
    Yong Liu
    Jing Nie
    Jie Niu
    Fangfang Meng
    Weiying Lin
    Scientific Reports, 7
  • [50] Effects of cystine and hydrogen peroxide on glutathione status and expression of antioxidant genes in Escherichia coli
    Smirnova, G.V.
    Muzyka, N.G.
    Oktyabrsky, O.N.
    Biokhimiya, 2005, 70 (08): : 1119 - 1129