A Room Temperature Bolometer for Terahertz Coherent and Incoherent Detection

被引:32
|
作者
Cherednichenko, Sergey [1 ]
Hammar, Arvid [1 ]
Bevilacqua, Stella [1 ]
Drakinskiy, Vladimir [1 ]
Stake, Jan
Kalabukhov, Alexey [2 ,3 ]
机构
[1] Chalmers Univ Technol, Terahertz & MillimetreWave Lab, Dept Microtechnol & Nanosci, SE-42196 Gothenburg, Sweden
[2] Chalmers Univ Technol, Quantum Device Phys Lab, Dept Microtechnol & Nanosci, SE-42196 Gothenburg, Sweden
[3] Moscow MV Lomonosov State Univ, Skobeltsyn Inst Nucl Phys, Moscow, Russia
基金
瑞典研究理事会;
关键词
Bolometer; mixer; room temperature detector; submillimeter; terahertz (THz); YBCO; MILLIMETER; MICROBOLOMETERS; NOISE;
D O I
10.1109/TTHZ.2011.2164654
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present a novel room temperature bolometer with nanosecond response that can be used both for coherent and incoherent detection through the entire terahertz frequency range. A responsivity of up to 15 V/W, and a noise equivalent power (NEP) similar to 450 pW/Hz(0.5) were measured at modulation frequencies from 0.5 kHz to 100 kHz. A conversion gain of -28 dB was demonstrated at an intermediate frequency of 20 MHz with a Local Oscillator power of 0.74 mW. Possible improvements of the bolometer characteristics are discussed.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 50 条
  • [11] Room Temperature Nb5N6 Bolometer for THz Detection
    Kang, L.
    Lu, X. H.
    Chen, J.
    Jin, B. B.
    Wu, P. H.
    Yao, Q. J.
    Shi, S. C.
    2009 34TH INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES, VOLS 1 AND 2, 2009, : 478 - +
  • [12] Room-temperature semiconductor coherent Smith-Purcell terahertz sources
    Smith, Don D.
    Belyanin, Alexey
    APPLIED PHYSICS LETTERS, 2011, 98 (06)
  • [13] Design and fabrication of a novel room temperature terahertz detection array
    Adam, AJL
    Klaassen, TO
    Hovenier, JN
    Sarro, PM
    CONFERENCE DIGEST OF THE 2004 JOINT 29TH INTERNATIONAL CONFERENCE ON INFRARED AND MILLIMETER WAVES AND 12TH INTERNATIONAL CONFERENCE ON TERAHERTZ ELECTRONICS, 2004, : 755 - 756
  • [14] Room temperature IR detection using pulsed laser deposited vanadium oxide bolometer
    Rajendra kumar, RT
    Karunagaran, B
    Mangalaraj, D
    Narayandass, SK
    Manoravi, P
    Joseph, M
    Gopal, V
    SMART MATERIALS, STRUCTURES, AND SYSTEM, PTS 1 AND 2, 2003, 5062 : 425 - 432
  • [15] Coherent detection with an incoherent local oscillator
    Mecozzi, Antonio
    Shtaif, Mark
    OPTICS EXPRESS, 2018, 26 (26): : 33970 - 33981
  • [16] ON SENSITIVITY AND NEP IN COHERENT AND INCOHERENT DETECTION
    BAUDRY, A
    ASTRONOMY & ASTROPHYSICS, 1970, 6 (02) : 325 - +
  • [17] Terahertz Direct Detection Characteristics of a Superconducting NbN Bolometer
    Ren Yuan
    Miao Wei
    Yao Qi-Jun
    Zhang Wen
    Shi Sheng-Cai
    CHINESE PHYSICS LETTERS, 2011, 28 (01)
  • [18] An exciton-polariton bolometer for terahertz radiation detection
    G. G. Paschos
    T. C. H. Liew
    Z. Hatzopoulos
    A. V. Kavokin
    P. G. Savvidis
    G. Deligeorgis
    Scientific Reports, 8
  • [19] Design and Imaging Application of Room-Temperature Terahertz Detector with Micro-Bolometer Focal Plane Array
    Jun Wang
    Jun Gou
    Zhi-Ming Wu
    Ya-Dong Jiang
    Journal of Electronic Science and Technology, 2016, (02) : 98 - 102
  • [20] Design and imaging application of room-temperature terahertz detector with micro-bolometer focal plane array
    Wang J.
    Gou J.
    Wu Z.-M.
    Jiang Y.-D.
    Journal of Electronic Science and Technology, 2016, 14 (02) : 98 - 102