The Use of a Standard Source of Synchrotron Radiation for Calibration of the Sensitivity of a Telescope with CCD Array and High Angular Resolution

被引:0
|
作者
Anevskii, S. I. [1 ]
Zolotarevskii, Yu. M. [1 ]
Krutikov, V. N. [1 ]
Lebedev, A. M. [2 ]
Minaeva, O. A. [1 ]
Minaev, R. V. [1 ]
Senin, D. S. [1 ]
Stankevich, V. G. [2 ]
机构
[1] All Russia Res Inst Optophys Measurements VNIIOFI, Moscow, Russia
[2] Natl Res Ctr Kurchatov Inst, Moscow, Russia
关键词
standard source; synchrotron radiation; electron storage ring; spectral density of irradiance; CCD array; telescope;
D O I
10.1007/s11018-015-0747-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A method involving the use of a primary standard source of synchrotron radiation for precision calibration of the sensitivity of telescopes equipped with a CCD array and high angular resolution is considered. The method is based on precision reproduction of the spectral energy characteristics, the Gaussian distribution of the spectral density of the irradiance over a radiating region, and the stability and reproducibility of the characteristics of synchrotron radiation in a single-electron regime.
引用
收藏
页码:520 / 525
页数:6
相关论文
共 36 条
  • [31] HIGH-RESOLUTION INFRARED MEASUREMENT OF THE V(10) BAND OF PROPYNE-D(1) USING A SYNCHROTRON-RADIATION SOURCE
    PASO, R
    HORNEMAN, VM
    JOURNAL OF MOLECULAR SPECTROSCOPY, 1995, 172 (02) : 536 - 542
  • [32] Ultrahigh-vacuum facility for high-resolution grazing-angle X-ray diffraction at a vertical wiggler source of synchrotron radiation
    Sakata, O.
    Tanaka, Y.
    Nikolaenko, A.M.
    Hashizume, H.
    Journal of Synchrotron Radiation, 1998, 5 (04) : 1222 - 1226
  • [33] Ultrahigh-vacuum facility for high-resolution grazing-angle X-ray diffraction at a vertical wiggler source of synchrotron radiation
    Sakata, O
    Tanaka, Y
    Nikolaenko, AM
    Hashizume, H
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1222 - 1226
  • [34] Method development for the determination of thallium in coal using solid sampling graphite furnace atomic absorption spectrometry with continuum source, high-resolution monochromator and CCD array detector
    Silva, AF
    Borges, DLG
    Welz, B
    Vale, MGR
    Silva, MM
    Klassen, A
    Heitmann, U
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (06) : 841 - 850
  • [35] High resolution-high energy x-ray photoelectron spectroscopy using third-generation synchrotron radiation source, and its application to Si-high k insulator systems
    Kobayashi, K
    Yabashi, M
    Takata, Y
    Tokushima, T
    Shin, S
    Tamasaku, K
    Miwa, D
    Ishikawa, T
    Nohira, H
    Hattori, T
    Sugita, Y
    Nakatsuka, O
    Sakai, A
    Zaima, S
    APPLIED PHYSICS LETTERS, 2003, 83 (05) : 1005 - 1007
  • [36] Development of a 6.65 m off-plane Eagle spectrometer for a high resolution vacuum ultraviolet beam-line at Indus-I synchrotron radiation source
    Das, NC
    Shukla, RP
    Udupa, DV
    Sahoo, NK
    Bhattacharya, D
    Sunanda, K
    Saraswathy, P
    Kumar, S
    Sinha, AK
    Bhat, S
    Sahni, VC