Non-Invasive and Real-Time Monitoring of the Breast Cancer Metastasis Degree via Metabolomics

被引:2
|
作者
Zhu, Wanfang [1 ,2 ]
Qian, Wenxin [1 ]
Liao, Wenting [1 ]
Huang, Xiaoxian [3 ]
Xu, Jiawen [1 ]
Qu, Wei [3 ]
Xue, Jingwei [4 ]
Feng, Feng [3 ,5 ]
Liu, Wenyuan [1 ,6 ]
Liu, Fulei [4 ,7 ]
Han, Lingfei [1 ]
机构
[1] China Pharmaceut Univ, Dept Pharmaceut Anal, Nanjing 210009, Peoples R China
[2] Changchun Univ Chinese Med, Coll Pharm, Changchun 130117, Peoples R China
[3] China Pharmaceut Univ, Dept Nat Med Chem, Nanjing 210009, Peoples R China
[4] Qingdao Univ, Affiliated Taian City Cent Hosp, Tumor Precise Intervent & Translat Med Lab, Tai An 271000, Shandong, Peoples R China
[5] Nanjing Med Univ, Sch Pharm, Nanjing 210029, Peoples R China
[6] Zhejiang Ctr Safety Study Drug Subst, Ind Technol Innovat Platform, Hangzhou 310018, Peoples R China
[7] Qingdao Univ, Affiliated Taian City Cent Hosp, Pharmaceut Dept, Tai An 271000, Shandong, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
breast cancer; liquid biopsy; metabolomics; metastasis; tumor microenvironment; INTERNATIONAL EXPERT CONSENSUS; TUMOR MICROENVIRONMENT; GENE-EXPRESSION; PRIMARY THERAPY; PET-CT; GROWTH; STAGE; ADENOCARCINOMA; OVEREXPRESSION; CELLS;
D O I
10.3390/cancers14225589
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Simple Summary Breast cancer (BC) is a serious threat to women's health and metastasis is the major cause of BC-associated mortality. Failure to detect and remove occult micrometastases limits the control of tumor recurrences. More precise non-invasive strategy needs to be developed for the detection of the tumor metastasis in lymph nodes and distant organs. Here, we suppose that the metabolomic method can be used to achieve non-invasive and real-time monitoring of BC metastatic status. We firstly described the metastatic status of BC mouse models with different tumor-bearing times. Secondly, metabonomics analysis and metastasis-related changes in the tumor microenvironment (TME) were performed in tumor-bearing mice with different metastatic states. The results showed that TME evolution can establish a link between metabolomics characteristics and tumor metastatic status. Finally, the changes of differential metabolite levels were also preliminarily confirmed in clinical BC samples and found that metabolite lysoPC (16:0) can be used for clinical N-stage diagnosis, and the possible causes of its changes was analyzed through bioinformatics technology. Breast cancer (BC) is a serious threat to women's health and metastasis is the major cause of BC-associated mortality. Various techniques are currently used to preoperatively describe the metastatic status of tumors, based on which a comprehensive treatment protocol was determined. However, accurately staging a tumor before surgery remains a challenge, which may lead to the miss of optimal treatment options. More severely, the failure to detect and remove occult micrometastases often causes tumor recurrences. There is an urgent need to develop a more precise and non-invasive strategy for the detection of the tumor metastasis in lymph nodes and distant organs. Based on the facts that tumor metastasis is closely related to the primary tumor microenvironment (TME) evolutions and that metabolomics profiling of the circulatory system can precisely reflect subtle changes within TME, we suppose whether metabolomic technology can be used to achieve non-invasive and real-time monitoring of BC metastatic status. In this study, the metastasis status of BC mouse models with different tumor-bearing times was firstly depicted to mimic clinical anatomic TNM staging system. Metabolomic profiling together with metastasis-related changes in TME among tumor-bearing mice with different metastatic status was conducted. A range of differential metabolites reflecting tumor metastatic states were screened and in vivo experiments proved that two main metastasis-driving factors in TME, TGF-beta and hypoxia, were closely related to the regular changes of these metabolites. The differential metabolites level changes were also preliminarily confirmed in a limited number of clinical BC samples. Metabolite lysoPC (16:0) was found to be useful for clinical N stage diagnosis and the possible cause of its changes was analyzed by bioinformatics techniques.
引用
收藏
页数:22
相关论文
共 50 条
  • [21] Non-invasive Vital Signs Monitoring System with Real-Time Caution and Emergency Alerts
    Cabanillas-Carbonell, Michael A.
    Zapata-Paulini, Joselyn E.
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [22] Non-invasive real-time genomic monitoring of the critically endangered kākāpō
    Urban, Lara
    Miller, Allison K.
    Eason, Daryl
    Vercoe, Deidre
    Shaffer, Megan
    Wilkinson, Shaun P.
    Jeunen, Gert-Jan
    Gemmell, Neil J.
    Digby, Andrew
    ELIFE, 2023, 12
  • [23] Non-invasive real-time monitoring of cell concentration and viability using Doppler ultrasound
    Akbari, Samin
    Anderson, Phillip
    Zang, Han
    Ganjian, Amin
    Balke, Robert
    Kwon, Taehong
    Pollard, David
    SLAS TECHNOLOGY, 2022, 27 (06): : 368 - 375
  • [24] Pulse Spectroscopy System for Non-Invasive Real-Time Monitoring of the Heart Beat Volume
    Andruschenko, S.
    Timm, U.
    Hinz, M.
    Koball, S.
    Kraitl, J.
    Lewis, E.
    Ewald, H.
    2010 IEEE SENSORS, 2010, : 1863 - 1868
  • [25] Detection of somatic mutations in plasma allows for non-invasive real-time therapy response monitoring of lung cancer patients
    Costa, Jose L.
    Fernandes, Gabriela
    Reis, Joana
    Silva, Miguel
    Hespanhol, Venceslau
    Machado, Jose C.
    CANCER RESEARCH, 2016, 76
  • [26] Real-Time Non-Invasive Monitoring of Short-Chain Fatty Acids in Exhaled Breath
    Meurs, Joris
    Sakkoula, Evangelia
    Cristescu, Simona M.
    FRONTIERS IN CHEMISTRY, 2022, 10
  • [27] Digital holography for real-time non-invasive monitoring of larval fish at power plant intakes
    Sanborn, Delaney
    Base, Alexis
    Garavelli, Lysel
    Barua, Ranjoy
    Hong, Jiarong
    Nayak, Aditya R.
    CANADIAN JOURNAL OF FISHERIES AND AQUATIC SCIENCES, 2023, 80 (09) : 1470 - 1481
  • [28] Non-invasive, continuous real-time monitoring of wrist blood pressure during anesthesia and operation
    Lu, WM
    Zhang, SM
    Feng, X
    Li, HP
    PROCEEDINGS OF THE WORLD ENGINEERS' CONVENTION 2004, VOL B, BIOLOGICAL ENGINEERING AND HEALTH CARE, 2004, : 171 - 177
  • [29] Development of a Non-invasive Deep Brain Stimulator With Precise Positioning and Real-Time Monitoring of Bioimpedance
    Wang, Heng
    Shi, Zhongyan
    Sun, Weiqian
    Zhang, Jianxu
    Wang, Jing
    Shi, Yue
    Yang, Ruoshui
    Li, Chunlin
    Chen, Duanduan
    Wu, Jinglong
    Gongyao, Guo
    Xu, Yifei
    FRONTIERS IN NEUROINFORMATICS, 2020, 14
  • [30] Real-time monitoring of Ca2+and pH using a non-invasive wearable biosensor
    Nyein, Hnin
    Gao, Wei
    Javey, Ali
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 253