Combination of electron energy-loss spectroscopy and energy dispersive x-ray spectroscopy to determine indium concentration in InGaN thin film structures

被引:4
|
作者
Wang, X. [1 ]
Chauvat, M. P. [2 ]
Ruterana, P. [2 ]
Walther, T. [1 ]
机构
[1] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
[2] CNRS, CIMAP, UMR 6252, ENSICAEN,CEA,UCBN, F-14050 Caen, France
关键词
InGaN; plasmon peak; electron energy-loss spectroscopy; EELS; EDXS; INVERSION DOMAIN BOUNDARIES; QUANTUM-WELLS; 0001; SAPPHIRE; GAN; LAYERS; DEFECTS; BAND;
D O I
10.1088/0268-1242/30/11/114011
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We demonstrate a method to determine the indium concentration, x, of InxGa1-xN thin films by combining plasmon excitation studies in electron energy-loss spectroscopy (EELS) with a novel way of quantification of the intensity of x-ray lines in energy-dispersive x-ray spectroscopy (EDXS). The plasmon peak in EELS of InGaN is relatively broad. We fitted a Lorentz function to the main plasmon peak to suppress noise and the influence from the neighboring Ga 3d transition in the spectrum, which improves the precision in the evaluation of the plasmon peak position. As the indium concentration of InGaN is difficult to control during high temperature growth due to partial In desorption, the nominal indium concentrations provided by the growers were not considered reliable. The indium concentration obtained from EDXS quantification using Oxford Instrument ISIS 300 x-ray standard quantification software often did not agree with the nominal indium concentration, and quantification using K and L lines was inconsistent. We therefore developed a self-consistent iterative procedure to determine the In content from thickness-dependent k-factors, as described in recent work submitted to Journal of Microscopy. When the plasmon peak position is plotted versus the indium concentration from EDXS we obtain a linear relationship over the whole compositional range, and the standard error from linear least-squares fitting shows that the indium concentration can be determined from the plasmon peak position to within Delta x = +/- 0.037 standard deviation.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Cryo-electron spectroscopic imaging, electron energy-loss spectroscopy and energy-dispersive x-ray analysis of Ag(Br,I) nano- and microcrystals
    Oleshko, VP
    Gijbels, RH
    Jacob, WA
    Van Daele, AJ
    MIKROCHIMICA ACTA, 1998, : 87 - 92
  • [22] ENERGY-DISPERSIVE X-RAY EMISSION SPECTROSCOPY
    FRANKEL, RS
    AITKEN, DW
    APPLIED SPECTROSCOPY, 1970, 24 (06) : 557 - &
  • [23] The Combination of Electron Microscopy, Raman Microscopy and Energy Dispersive X-Ray Spectroscopy for the Investigation of Polymeric Materials
    Schmidt, Ruth
    Fitzek, Harald
    Nachtnebel, Manfred
    Mayrhofer, Claudia
    Schroettner, Hartmuth
    Zankel, Armin
    MACROMOLECULAR SYMPOSIA, 2019, 384 (01)
  • [24] Energy-Dispersive X-Ray Spectroscopy of Atomically Thin Semiconductors and Heterostructures
    Rupp, Anna
    Goeser, Jonas
    Li, Zhijie
    Altpeter, Philipp
    Bilgin, Ismail
    Hoegele, Alexander
    PHYSICAL REVIEW APPLIED, 2022, 18 (06)
  • [25] Spatial high resolution energy dispersive X-ray spectroscopy on thin lamellas
    Notthoff, Christian
    Winterer, Markus
    Beckel, Andreas
    Geller, Martin
    Heindl, Juergen
    ULTRAMICROSCOPY, 2013, 129 : 30 - 35
  • [26] Electron energy-loss and soft X-ray emission spectroscopy of electronic structure of MgB4
    Sato, Yohei
    Saito, Taiki
    Tsuchiya, Kohei
    Terauchi, Masami
    Saito, Hiroki
    Takeda, Masatoshi
    JOURNAL OF SOLID STATE CHEMISTRY, 2017, 253 : 58 - 62
  • [27] BIOMEDICAL AND AGRICULTURAL APPLICATIONS OF ENERGY DISPERSIVE X-RAY SPECTROSCOPY IN ELECTRON MICROSCOPY
    Wyroba, Elzbieta
    Suski, Szymon
    Miller, Karolina
    Bartosiewicz, Rafal
    CELLULAR & MOLECULAR BIOLOGY LETTERS, 2015, 20 (03) : 488 - 509
  • [28] Demonstration of lanthanum in liver cells by energy-dispersive X-ray spectroscopy, electron energy loss spectroscopy and high-resolution transmission electron microscopy
    Yang, Z.
    Schryvers, D.
    Roels, F.
    D'Haese, P. C.
    De Broe, M. E.
    JOURNAL OF MICROSCOPY, 2006, 223 : 133 - 139
  • [29] Improving the energy resolution of X-ray and electron energy-loss spectra
    Egerton, R. F.
    Qian, H.
    Malac, M.
    MICRON, 2006, 37 (04) : 310 - 315
  • [30] A STUDY OF ORGANIC INORGANIC INTERACTIONS IN SYNCRUDE FINES BY X-RAY PHOTOELECTRON-SPECTROSCOPY AND CORE ELECTRON ENERGY-LOSS SPECTROSCOPY
    ZAJAC, GW
    FLEISCH, TH
    LEE, FSC
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1988, 6 (03): : 1118 - 1122