Combination of electron energy-loss spectroscopy and energy dispersive x-ray spectroscopy to determine indium concentration in InGaN thin film structures
被引:4
|
作者:
Wang, X.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, EnglandUniv Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
Wang, X.
[1
]
Chauvat, M. P.
论文数: 0引用数: 0
h-index: 0
机构:
CNRS, CIMAP, UMR 6252, ENSICAEN,CEA,UCBN, F-14050 Caen, FranceUniv Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
Chauvat, M. P.
[2
]
Ruterana, P.
论文数: 0引用数: 0
h-index: 0
机构:
CNRS, CIMAP, UMR 6252, ENSICAEN,CEA,UCBN, F-14050 Caen, FranceUniv Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
Ruterana, P.
[2
]
Walther, T.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, EnglandUniv Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
Walther, T.
[1
]
机构:
[1] Univ Sheffield, Dept Elect & Elect Engn, Sheffield S1 3JD, S Yorkshire, England
[2] CNRS, CIMAP, UMR 6252, ENSICAEN,CEA,UCBN, F-14050 Caen, France
We demonstrate a method to determine the indium concentration, x, of InxGa1-xN thin films by combining plasmon excitation studies in electron energy-loss spectroscopy (EELS) with a novel way of quantification of the intensity of x-ray lines in energy-dispersive x-ray spectroscopy (EDXS). The plasmon peak in EELS of InGaN is relatively broad. We fitted a Lorentz function to the main plasmon peak to suppress noise and the influence from the neighboring Ga 3d transition in the spectrum, which improves the precision in the evaluation of the plasmon peak position. As the indium concentration of InGaN is difficult to control during high temperature growth due to partial In desorption, the nominal indium concentrations provided by the growers were not considered reliable. The indium concentration obtained from EDXS quantification using Oxford Instrument ISIS 300 x-ray standard quantification software often did not agree with the nominal indium concentration, and quantification using K and L lines was inconsistent. We therefore developed a self-consistent iterative procedure to determine the In content from thickness-dependent k-factors, as described in recent work submitted to Journal of Microscopy. When the plasmon peak position is plotted versus the indium concentration from EDXS we obtain a linear relationship over the whole compositional range, and the standard error from linear least-squares fitting shows that the indium concentration can be determined from the plasmon peak position to within Delta x = +/- 0.037 standard deviation.