Simplified computational approach for dual-probe heat-pulse method

被引:2
|
作者
Knight, JH
Kluitenberg, GJ [1 ]
机构
[1] Kansas State Univ, Dept Agron, Manhattan, KS 66506 USA
[2] Australian Natl Univ, Inst Math Sci, Canberra, ACT 0200, Australia
[3] CSIRO, Land & Water, Canberra, ACT 2601, Australia
关键词
D O I
暂无
中图分类号
S15 [土壤学];
学科分类号
0903 ; 090301 ;
摘要
Two equations are currently available for estimating soil volumetric heat capacity (pc) with the dual-probe heat-pulse (DPHP) method. One is simple but gives only approximate results because it assumes that the DPHP sensor releases an impulse of heat instantaneously. The other explicitly accounts for the finite duration of heating and gives exact results. Unfortunately, the equation that gives exact results involves the exponential integral function, which is not available in most computer spreadsheet software packages or data logger function libraries. In this note we introduce an approximation of the exact equation that contains only simple algebraic functions. The approximation consists of the first five terms of a Taylor series, which are written as a telescoped polynomial for computational purposes. For most applications of the DPHP method, the polynomial approximation gives estimates of pc that are at least an order of magnitude more accurate than estimates obtained from the simple equation based on instantaneous heating.
引用
收藏
页码:447 / 449
页数:3
相关论文
共 50 条
  • [41] Development of probe-to-probe approach method for an independently controlled dual-probe scanning tunneling microscope
    Matsui, Atsuteru
    Shigeta, Yukichi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2007, 78 (10):
  • [42] Optimizing probe structure for dual-probe seafloor heat flow meter
    Yang Xiao-Qiu
    Shi Xiao-Bin
    Xu He-Hua
    Xu Xing
    Li Guan-Bao
    Guo Xing-Wei
    Luo Xian-Hu
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2009, 52 (05): : 1280 - 1288
  • [43] Improving a Dual-Probe Heat Pulse Based Soil Moisture Sensor Using Insulated Nichrome Wire
    Raman, Adhiti
    Ananthasuresh, G. K.
    2015 2nd International Symposium on Physics and Technology of Sensors, 2015, : 283 - 288
  • [44] Comments on "On the construction and calibration of dual-probe heat capacity sensors"
    Phillips, NG
    Salvucci, GD
    Pettijohn, JC
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2005, 69 (05) : 1666 - 1666
  • [45] A heat-pulse method for detecting ice formation on surfaces
    Dongo, Patrice D.
    Machrafi, Hatim
    Minetti, C.
    Amato, Alessandro
    Queeckers, P.
    Iorio, C. S.
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2021, 22
  • [46] An Improved Dual-probe Approach to Measure Noise Source Impedance
    Bo, Zhao
    Min, Zhao
    Feng Zhiming
    Shui Limin
    Min, Yao
    2010 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & TECHNICAL EXHIBITION ON EMC RF/MICROWAVE MEASUREMENTS & INSTRUMENTATION, 2010, : 214 - 217
  • [47] Standard Resistor Calibration Method in Measurement of Noise Source Impedance Using Dual-probe Approach
    Zhao Bo
    Zhao Min
    Feng Zhiming
    Yao Min
    CEEM: 2009 5TH ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, 2009, : 408 - +
  • [48] Measuring Subsurface Soil-Water Evaporation with an Improved Heat-Pulse Probe
    Xiao, Zhang
    Lu, Sen
    Heitman, Joshua
    Horton, Robert
    Ren, Tusheng
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2012, 76 (03) : 876 - 879
  • [49] A general in situ probe spacing correction method for dual probe heat pulse sensor
    Liu, Gang
    Wen, Minmin
    Ren, Ruiqi
    Si, Bing
    Horton, Robert
    Hu, Kelin
    AGRICULTURAL AND FOREST METEOROLOGY, 2016, 226 : 50 - 56
  • [50] Measurement of soil-surface heat flux with a multi-needle heat-pulse probe
    Peng, X.
    Wang, Y.
    Heitman, J. .
    Ochsner, T.
    Horton, R.
    Ren, T.
    EUROPEAN JOURNAL OF SOIL SCIENCE, 2017, 68 (03) : 336 - 344