Leakage Current Monitoring for Silane Epoxy Resin Insulator under Tropical Climate Conditions

被引:0
|
作者
Syakur, Abdul [1 ]
Berahim, Hamzah [1 ]
Rochmadi, Tumiran [2 ]
机构
[1] Gadjah Mada Univ, Dept Elect Engn, Yogyakarta, Indonesia
[2] Gadjah Mada Univ, Dept Chem Engn, Yogyakarta, Indonesia
来源
PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012) | 2012年
关键词
leakage current; temperature; humidity; insulator;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Polymer outdoor insulators have been developed and used on transmission lines and power distribution network. A polymeric insulating material that is widely used is epoxy resin and silicone rubber. Each material has its own advantages and disadvantages. Generally, polymeric materials have dielectric properties better than the ceramic, glass and porcelain materials. The dominant factors affecting performance of outdoor insulators are like temperature, rain, humidity, ultraviolet rays, condensation and contaminant. As a results, the insulator surface will be easily contaminated and flow current. For a long time, these events can cause damage to the surface of the insulator and finally cause flashover. To improve the surface properties of materials, silicon rubber material that has the ability to repel water were added. Silica sand was mixed with silicon rubber to improve the mechanical properties. In this paper, the influence of tropical climate conditions such as temperature, humidity, wet and dry conditions on leakage current characteristic of 20 kV outdoor insulators with silane epoxy resin has been investigated. The test was conducted on laboratory with AC high voltage 50 Hz and range of temperature from 30 degrees C to 60 degrees C and range of humidity from 40% RH to 70% RH were applied to the insulators. The chamber was used to placing the insulator. The monitoring results showed that the leakage currents on insulator surface were affected by temperature and humidity. A minimum leakage current occurs at 40% RH and a maximum current occurs at 70% RH. Meanwhile, the influence of the ambient temperature at leakage current is less significant because it ignores the factor of air pressure and humidity.
引用
收藏
页码:878 / 881
页数:4
相关论文
共 50 条
  • [31] Leakage Current Characteristics of 132kV Polymeric and Porcelain Insulator Under Various Polluted Conditions
    Rasamsetti, S. Sudhakar
    Sumathi, N.
    2017 IEEE INTERNATIONAL CONFERENCE ON POWER, CONTROL, SIGNALS AND INSTRUMENTATION ENGINEERING (ICPCSI), 2017, : 1535 - 1540
  • [32] Risk Assessment of Polluted Glass Insulator Using Leakage Current Index Under Different Operating Conditions
    Salem, Ali Ahmed
    Abd-Rahman, Rahisham
    Al-Gailani, Samir Ahmed
    Salam, Zainal
    Kamarudin, Muhammad Saufi
    Zainuddin, Hidayat
    Yousof, Mohd Fairouz Mohd
    IEEE ACCESS, 2020, 8 : 175827 - 175839
  • [33] Frequency Analysis of the Leakage Current under Non Uniform Polluted Conditions on One Insulator Plane Model
    Douar, M. A.
    Mekhaldi, A.
    Bouzidi, M. C.
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [34] Self-Normalizing Multivariate Analysis of Polymer Insulator Leakage Current Under Severe Fog Conditions
    Liu, Yong
    Du, Boxue X.
    Farzaneh, Masoud
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (03) : 1279 - 1286
  • [35] Monitoring method for leakage current of transmission line insulators under typical environmental conditions
    Hu, Xie
    Xu, Kun
    Lai, Bingchuan
    Wu, Dan
    Hao, Changjin
    Journal of Physics: Conference Series, 2021, 2125 (01):
  • [36] Condition Monitoring of Overhead line Insulator By measuring Surface Leakage Current
    Banik, Apu
    Dalai, Sovan
    Chatterjee, Biswendu
    2014 Annual IEEE India Conference (INDICON), 2014,
  • [37] A new broadband microcurrent transducer for insulator leakage current monitoring system
    Chen, Weigen
    Yao, Chenguo
    Chen, Pan
    Sun, Caixin
    Du, Lin
    Liao, Ruijin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (01) : 355 - 360
  • [38] On-line Monitoring System of Insulator Leakage Current Based on ARM
    Zuo Tingtao
    Liu Tianyu
    Chen Ke
    Hu Xiaoguang
    2012 10TH IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL INFORMATICS (INDIN), 2012, : 75 - 79
  • [39] Recurrent Plot Analysis of Leakage Current for Monitoring Outdoor Insulator Performance
    Du, B. X.
    Liu, Yong
    Liu, H. J.
    Yang, Y. J.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2009, 16 (01) : 139 - 146
  • [40] Vibration Triggered Leakage of Surface Charge on Epoxy Insulator Under DC Voltage
    Gao, Y.
    Lu, D.
    Yuan, X. C.
    Han, T.
    Du, B. X.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2023, 30 (04) : 1893 - 1901