A note on determination of the diffuse-field sensitivity of microphones using the reciprocity technique

被引:5
|
作者
Barrera-Figueroa, Salvador [1 ]
Rasmussen, Knud [1 ]
Jacobsen, Finn [2 ]
机构
[1] Danish Fundamental Metrol, Danish Primary Lab Acoust, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Dept Elect Engn, DK-2800 Lyngby, Denmark
来源
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA | 2008年 / 124卷 / 03期
关键词
D O I
10.1121/1.2950089
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The diffuse-field response of a microphone is usually obtained by adding a random-incidence correction to the pressure response of the microphone. However, the random-incidence correction is determined from a relative measurement, and its accuracy depends not only on the relative response at all angles of incidence but also on the accuracy of the frequency response at normal incidence. By contrast, this paper is concerned with determining the absolute diffuse-field response of a microphone using the reciprocity technique. To examine this possibility, a reciprocity calibration setup is used for measuring the electrical transfer impedance between a pair of microphones placed in a miniature (2 m(3)) reverberation room. The transfer function between the microphones is measured using fast Fourier transform analysis and pseudorandom noise. The calculation of the diffuse-field sensitivity involves (a) separation of the reverberant response from the total response, (b) determination of the reverberation time, and (c) averaging over space and frequency. The resulting diffuse-field correction is compared with an estimate of the random-incidence correction determined in an anechoic room and with a numerical prediction. (C) 2008 Acoustical Society of America.
引用
收藏
页码:1505 / 1512
页数:8
相关论文
共 50 条
  • [41] A Measurement Technique for Static Determination of RFID Tags' Sensitivity Using a Low-cost UHF GTEM Cell
    Valmiro, R.
    Barbin, S. E.
    2014 8TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2014, : 1109 - 1113
  • [42] Validation of diffuse correlation spectroscopy sensitivity to nicotinamide-induced blood flow elevation in the murine hindlimb using the fluorescent microsphere technique
    Proctor, Ashley R.
    Ramirez, Gabriel A.
    Han, Songfeng
    Liu, Ziping
    Bubel, Tracy M.
    Choe, Regine
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (03)
  • [43] DETERMINATION OF ELECTRICAL TRANSPORT-PROPERTIES USING A NOVEL MAGNETIC FIELD-DEPENDENT HALL TECHNIQUE
    BECK, WA
    ANDERSON, JR
    JOURNAL OF APPLIED PHYSICS, 1987, 62 (02) : 541 - 544
  • [44] Determination of in-situ engineering properties of soil using an inverse solution technique and limited field tests
    Zhang, Qingsong
    Upadhyaya, Shrini K.
    Liao, Qingxi
    Li, Xuan
    JOURNAL OF TERRAMECHANICS, 2018, 79 : 69 - 77
  • [45] Determination of Electric-Field Profile in CdTe and CdZnTe Detectors Using Transient-Current Technique
    Uxa, Stepan
    Belas, Eduard
    Grill, Roman
    Praus, Petr
    James, Ralph B.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2012, 59 (05) : 2402 - 2408
  • [46] Determination of sensitivity versus frequency characteristics of miniature ultrasonic hydrophones below 1 MHz using planar scanning technique
    Devaraju, V
    Lewin, PA
    Bleeker, H
    JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (03) : 261 - 268
  • [47] DETERMINATION OF ELECTRIC-FIELD DISTRIBUTIONS ALONG FLUID-SOLID DIELECTRIC INTERFACES USING A SCHLIEREN TECHNIQUE
    SUEDA, H
    KAO, KC
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1982, 17 (05): : 405 - 413
  • [48] A new numerical technique of electric field determination within dielectric materials plate and cable using the TSM method
    Belgaroui, E
    Guermazi, H
    Agnel, S
    Mlik, Y
    Toureille, A
    EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2003, 23 (01): : 63 - 71
  • [49] High-sensitivity Determination of Curcumin in Human Urine Using Gemini Zwitterionic Surfactant as a Probe by Resonance Light Scattering Technique
    Chen, Xi
    Liang, Shengwang
    Zhu, Li
    Liu, Jinbin
    Zhang, Guomin
    Chen, Zhanguang
    PHYTOCHEMICAL ANALYSIS, 2012, 23 (05) : 456 - 461
  • [50] Thirty fold increased sensitivity in the determination of PCBs in water and soil by GC-ECD using large volume splitless technique
    Porzano, Thomas
    Cadoppi, Andrea
    LC GC EUROPE, 2006, : 14 - 14