Computer-Aided Design of Customized Foot Orthoses: Reproducibility and Effect of Method Used to Obtain Foot Shape

被引:32
|
作者
Telfer, Scott [1 ]
Gibson, Kellie S. [1 ]
Hennessy, Kym [1 ]
Steultjens, Martijn P. [1 ]
Woodburn, Jim [1 ]
机构
[1] Glasgow Caledonian Univ, Sch Hlth & Life Sci, Glasgow G4 0BA, Lanark, Scotland
来源
关键词
Computer-aided design; Orthotic devices; Rehabilitation; PLANTAR PRESSURE; IMPRESSION;
D O I
10.1016/j.apmr.2011.12.019
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Teller S, Gibson KS, Hennessy K, Steultjens MP, Woodburn J. Computer-aided design of customized foot orthoses: reproducibility and effect of method used to obtain foot shape. Arch Phys Med Rehabil 2012;93:863-70. Objective: To determine, for a number of techniques used to obtain foot shape based around plaster casting, foam box impressions, and 3-dimensional scanning, (1) the effect the technique has on the overall reproducibility of custom foot orthoses (FOs) in terms of inter- and intracaster reliability and (2) the reproducibility of FO design by using computer-aided design (CAD) software in terms of inter- and intra-CAD operator reliability for all these techniques. Design: Cross-sectional study. Setting: University laboratory. Participants: Convenience sample of individuals (N=22) with noncavus foot types. Interventions: Not applicable. Main Outcome Measures: Parameters of the FO design (length, width at forefoot, width at rearfoot, and peak medial arch height), the forefoot to rearfoot angle of the foot shape, and overall volume match between device designs. Results: For intra- and intercaster reliability of the different methods of obtaining the foot shape, all methods fell below the reproducibility quality threshold for the medial arch height of the device, and volume matching was <80% for all methods. The more experienced CAD operator was able to achieve excellent reliability (intraclass correlation coefficients >0.75) for all variables with the exception of forefoot to rearfoot angle, with overall volume matches of >87% of the devices. Conclusions: None of the techniques for obtaining foot shape met all the criteria for excellent reproducibility, with the peak arch height being particularly variable. Additional variability is added at the CAD stage of the FO design process, although with adequate operator experience good to excellent reproducibility may be achieved at this stage. Taking only basic linear or angular measurement parameters from the device may fail to fully capture the variability in FO design.
引用
收藏
页码:863 / 870
页数:8
相关论文
共 50 条
  • [31] A PREDICTABLE AND REPEATABLE METHOD TO RAPIDLY MANUFACTURE FUNCTION-CUSTOMIZED PASSIVE-DYNAMIC ANKLE FOOT ORTHOSES
    Schrank, Elisa S.
    Razzook, Alexander
    Takahashi, Kota
    Tierney, John
    Gillespie, John W., Jr.
    Hitch, Lester
    Wallace, Kevin
    Moore, Rick
    Higginson, Jill S.
    Stanhope, Steven J.
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 1237 - 1238
  • [32] A method for the measurement of three-dimensional geometry of casts used for the manufacture of ankle foot orthoses
    Sykes, N
    Peacock, JC
    Johnson, GR
    CLINICAL BIOMECHANICS, 1998, 13 (07) : 542 - 547
  • [33] Eighteen-Month Outcomes of Titanium Frameworks Using Computer-Aided Design and Computer-Aided Manufacturing Method
    Turkyilmaz, Ilser
    Asar, Neset Volkan
    IMPLANT DENTISTRY, 2017, 26 (03) : 480 - 484
  • [34] ASSESSING THE EFFECT OF INCENTIVE ON COMPUTER-AIDED DESIGN INTENT
    Johnson, Michael D.
    Diwakaran, Ram Prasad
    ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, PROCEEDINGS, VOL 2, PTS A AND B, 2010, : 523 - 532
  • [35] Computer-Aided Design Bitmap Retrieval Methods Based on Shape Features
    Yin, Yuan
    Gao, Shengxiang
    Yu, Zhengtao
    Zhang, Yunshan
    2015 12th International Conference on Fuzzy Systems and Knowledge Discovery (FSKD), 2015, : 1275 - 1279
  • [36] Computer-aided feature-based design for net shape manufacturing
    Chen, YM
    Wei, CL
    COMPUTER INTEGRATED MANUFACTURING SYSTEMS, 1997, 10 (02): : 147 - 164
  • [37] Standard vs computer-aided design/computer-aided manufacturing customized self-ligating systems using indirect bonding with both: A comparative study
    Jackers, Nastasia
    Maes, Nathalie
    Lambert, France
    Albert, Adelin
    Charavet, Carole
    ANGLE ORTHODONTIST, 2021, 91 (01) : 74 - 80
  • [38] Computer-Aided Teaching System Design Method for Information Design Specialty
    Yuan X.
    Bi H.
    Niu X.
    Computer-Aided Design and Applications, 2023, 20 (S4): : 44 - 55
  • [39] REPRODUCIBILITY OF COMPUTER-AIDED SEMEN ANALYSIS - COMPARISON OF 5 DIFFERENT SYSTEMS USED IN A PRACTICAL WORKSHOP
    HOLT, W
    WATSON, P
    CURRY, M
    HOLT, C
    FERTILITY AND STERILITY, 1994, 62 (06) : 1277 - 1282
  • [40] Examining the learning by teaching method in computer-aided design instruction
    Peng X.
    Zhang D.
    Jackson M.
    Yalvac B.
    Ketsetzi A.
    Eseryel D.
    Computer-Aided Design and Applications, 2018, 16 (01): : 129 - 139