Computer-Aided Design of Customized Foot Orthoses: Reproducibility and Effect of Method Used to Obtain Foot Shape

被引:32
|
作者
Telfer, Scott [1 ]
Gibson, Kellie S. [1 ]
Hennessy, Kym [1 ]
Steultjens, Martijn P. [1 ]
Woodburn, Jim [1 ]
机构
[1] Glasgow Caledonian Univ, Sch Hlth & Life Sci, Glasgow G4 0BA, Lanark, Scotland
来源
关键词
Computer-aided design; Orthotic devices; Rehabilitation; PLANTAR PRESSURE; IMPRESSION;
D O I
10.1016/j.apmr.2011.12.019
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Teller S, Gibson KS, Hennessy K, Steultjens MP, Woodburn J. Computer-aided design of customized foot orthoses: reproducibility and effect of method used to obtain foot shape. Arch Phys Med Rehabil 2012;93:863-70. Objective: To determine, for a number of techniques used to obtain foot shape based around plaster casting, foam box impressions, and 3-dimensional scanning, (1) the effect the technique has on the overall reproducibility of custom foot orthoses (FOs) in terms of inter- and intracaster reliability and (2) the reproducibility of FO design by using computer-aided design (CAD) software in terms of inter- and intra-CAD operator reliability for all these techniques. Design: Cross-sectional study. Setting: University laboratory. Participants: Convenience sample of individuals (N=22) with noncavus foot types. Interventions: Not applicable. Main Outcome Measures: Parameters of the FO design (length, width at forefoot, width at rearfoot, and peak medial arch height), the forefoot to rearfoot angle of the foot shape, and overall volume match between device designs. Results: For intra- and intercaster reliability of the different methods of obtaining the foot shape, all methods fell below the reproducibility quality threshold for the medial arch height of the device, and volume matching was <80% for all methods. The more experienced CAD operator was able to achieve excellent reliability (intraclass correlation coefficients >0.75) for all variables with the exception of forefoot to rearfoot angle, with overall volume matches of >87% of the devices. Conclusions: None of the techniques for obtaining foot shape met all the criteria for excellent reproducibility, with the peak arch height being particularly variable. Additional variability is added at the CAD stage of the FO design process, although with adequate operator experience good to excellent reproducibility may be achieved at this stage. Taking only basic linear or angular measurement parameters from the device may fail to fully capture the variability in FO design.
引用
收藏
页码:863 / 870
页数:8
相关论文
共 50 条
  • [1] COMPUTER-AIDED DESIGN AND COMPUTER-AIDED MANUFACTURING OF FOOT ORTHOSES
    STAATS, TB
    KRIECHBAUM, MP
    JOURNAL OF PROSTHETICS AND ORTHOTICS, 1989, 1 (03) : 182 - 186
  • [2] Design of customized articulated ankle-foot orthoses by using reverse engineering and computer-aided design tools
    Erkizia, Gaizka
    Amezua, Xabier
    Etxaniz, Olatz
    Jauregi, Mikel
    DYNA, 2025, 100 (01): : 6 - 8
  • [3] Toward subtalar joint axis-driven computer-aided design and computer-aided manufacturing foot orthoses: Reliability of a noninvasive clinical scanning protocol
    Potier, Clement
    Claeys, Kurt
    Deschamps, Kevin
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2025, 49 (01) : 83 - 91
  • [4] The use of computer-aided design and manufacture for foot orthoses: A cross-sectional study of orthotic services in the UK
    Barr, Laura
    Richards, Jim
    Chapman, Graham J.
    JOURNAL OF FOOT AND ANKLE RESEARCH, 2025, 18 (01)
  • [5] Computer-Aided Design/Computer-Aided Manufacturing Technology in Customized Orthodontic Appliances
    Grauer, Dan
    Wiechmann, Dirk
    Heymann, Gavin C.
    Swift, Edward J., Jr.
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2012, 24 (01) : 3 - 9
  • [6] Computer-Aided Design and Manufacturing of Customized Insoles
    Huang, Chung-Neng
    Lee, Ming-Yih
    Chang, Chong-Ching
    IEEE COMPUTER GRAPHICS AND APPLICATIONS, 2011, 31 (02) : 74 - 79
  • [7] COMPUTER-AIDED CUSTOMIZED SHAPE DESIGN OF AN N95 FILTERING FACEPIECE RESPIRATOR
    Lei, Zhipeng
    Yang, James
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, 2013, VOL 3B, 2014,
  • [8] A computer-aided design system for foot-feature-based shoe last customization
    Xiong, Shuping
    Zhao, Jianhui
    Jiang, Zuhua
    Dong, Ming
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2010, 46 (1-4): : 11 - 19
  • [9] A computer-aided design system for foot-feature-based shoe last customization
    Shuping Xiong
    Jianhui Zhao
    Zuhua Jiang
    Ming Dong
    The International Journal of Advanced Manufacturing Technology, 2010, 46 : 11 - 19