Computed tomographic images using tube source of X-rays: Interior properties of the material

被引:0
|
作者
Rao, DV [1 ]
Takeda, T [1 ]
Itai, Y [1 ]
Seltzer, SM [1 ]
Hubbell, JH [1 ]
Zeniya, T [1 ]
Akatsuka, T [1 ]
Cesareo, R [1 ]
Brunetti, A [1 ]
Gigante, G [1 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba, Ibaraki 3058575, Japan
来源
关键词
plastic; materials; image intensifier; optimum energy; monochromacy; soft materials; profile; Monte Carlo methods;
D O I
10.1117/12.452870
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An image intensifier based computed tomography scanner and a tube source of X-rays are used to obtain the images of small objects, plastics, wood and soft materials in order to know the interior properties of the material. A new method is developed to estimate the dgree of monochromacy, total soild angle, efficiency and geometrical effects of the measuring system and the way to produce monoenergetic radiation. The flux emitted by the X-ray tube is filtered using the appropriate filters at the chosen optimum energy and reasonable monochromacy is achieved and the images are acceptably distinct. Much attention has been focused on the imaging of small objects of weakly attenuating materials at optimum value. At optimum value it is possible to calculate the three dimensional representation of inner and outer surfaces of the object. The image contrast between soft materials could be significantly enhanced by optimal selection of the energy of the X-rays by Monte Carlo methods. The imaging system is compact, reasonably economic, has a good contrast resolution, simple operation and routine availability and explore the use of optimizing tomography for various applications. Keywords: Plastic, materials, image intensifier, optimum energy, monochromacy, soft materials, profile, Monte Carlo methods.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 50 条
  • [21] Production of X-rays without a focus tube
    Reboul, G
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES, 1927, 184 : 1436 - 1438
  • [22] A tube for the production of monochromatic and fluorescent x-rays
    Pierce, WC
    Olson, CM
    MacMillan, DP
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1937, 8 : 145 - 147
  • [23] Material properties - X-rays go where neutrons fear to tread
    Watson, A
    SCIENCE, 1997, 277 (5330) : 1216 - 1217
  • [24] Enhancement of Dental X-rays Images Using Image Processing Techniques
    Abdallah, Yousif Mohamed Y.
    Abuhadi, Nouf H.
    Mugri, Maryam H.
    JOURNAL OF RESEARCH IN MEDICAL AND DENTAL SCIENCE, 2021, 9 (02): : 12 - 16
  • [25] The images of coins provoked by radium or x-rays
    Jensen, C
    ANNALEN DER PHYSIK, 1906, 21 (15) : 901 - 912
  • [26] EFFECTS OF SCATTERED X-RAYS ON CT IMAGES
    KANAMORI, H
    NAKAMORI, N
    INOUE, K
    TAKENAKA, E
    PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (03): : 239 - 249
  • [27] A NEW TOMOGRAPHIC DEVICE BASED ON THE DETECTION OF FLUORESCENT X-RAYS
    CESAREO, R
    MASCARENHAS, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3): : 669 - 672
  • [28] X-rays during material testing.
    不详
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1921, 65 : 580 - 580
  • [29] Application of x-rays for material testing.
    Sachs, G
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1926, 70 : 1634 - 1640
  • [30] Analysis of the EMCCD point-source response using x-rays
    Kotov, I., V
    Hall, S.
    Gopinath, D.
    Barbour, A.
    Li, J.
    Gu, Y.
    Holland, K.
    Holland, A.
    Jarrige, I
    Pelliciari, J.
    Soman, M.
    Wilkins, S.
    Bisogni, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 985 (985):