Computed tomographic images using tube source of X-rays: Interior properties of the material

被引:0
|
作者
Rao, DV [1 ]
Takeda, T [1 ]
Itai, Y [1 ]
Seltzer, SM [1 ]
Hubbell, JH [1 ]
Zeniya, T [1 ]
Akatsuka, T [1 ]
Cesareo, R [1 ]
Brunetti, A [1 ]
Gigante, G [1 ]
机构
[1] Univ Tsukuba, Inst Clin Med, Tsukuba, Ibaraki 3058575, Japan
来源
关键词
plastic; materials; image intensifier; optimum energy; monochromacy; soft materials; profile; Monte Carlo methods;
D O I
10.1117/12.452870
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An image intensifier based computed tomography scanner and a tube source of X-rays are used to obtain the images of small objects, plastics, wood and soft materials in order to know the interior properties of the material. A new method is developed to estimate the dgree of monochromacy, total soild angle, efficiency and geometrical effects of the measuring system and the way to produce monoenergetic radiation. The flux emitted by the X-ray tube is filtered using the appropriate filters at the chosen optimum energy and reasonable monochromacy is achieved and the images are acceptably distinct. Much attention has been focused on the imaging of small objects of weakly attenuating materials at optimum value. At optimum value it is possible to calculate the three dimensional representation of inner and outer surfaces of the object. The image contrast between soft materials could be significantly enhanced by optimal selection of the energy of the X-rays by Monte Carlo methods. The imaging system is compact, reasonably economic, has a good contrast resolution, simple operation and routine availability and explore the use of optimizing tomography for various applications. Keywords: Plastic, materials, image intensifier, optimum energy, monochromacy, soft materials, profile, Monte Carlo methods.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 50 条
  • [1] Tomographic images of few soft materials and embedded biological soft tissue using tube source of X-rays at optimum energy
    Rao, DV
    Yuasa, T
    Akatsuka, T
    Cesareo, R
    Gigante, GE
    Takeda, T
    NDT & E INTERNATIONAL, 2006, 39 (01) : 34 - 38
  • [2] Images of weakly attenuating materials and nondestructive evaluation using a tube source of X-rays
    Rao, DV
    Cesareo, R
    Brunetti, A
    JOURNAL OF TRACE AND MICROPROBE TECHNIQUES, 2000, 18 (02): : 257 - 273
  • [3] MULTI-ELEMENT IMAGING IN CT USING A TUBE SOURCE OF X-RAYS
    FRYAR, J
    MCCARTHY, KJ
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1989, 36 (01) : 1138 - 1143
  • [4] Influence of porosities on x-rays tomographic measurements
    Masounave, S
    Bathias, C
    Masounave, J
    LIGHT METALS 2000 METAUX LEGERS, PROCEEDINGS, 2000, : 123 - 136
  • [5] A SOURCE OF X-RAYS USING RESONANCE TRANSITION RADIATION
    CHU, AN
    PIESTRUP, MA
    FINMAN, PF
    PANTELL, RH
    GEARHART, RA
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 336 - 339
  • [6] X-UV MULTILAYER REFLECTIVITY TESTS USING WINDOWLESS SOFT X-RAYS TUBE AND SYNCHROTRON SOURCE
    BARCHEWITZ, R
    MARMORET, R
    REVUE DE PHYSIQUE APPLIQUEE, 1988, 23 (10): : 1661 - 1674
  • [7] X-RAYS FROM TELEVISION TUBE
    不详
    BMJ-BRITISH MEDICAL JOURNAL, 1968, 1 (5594): : 755 - +
  • [8] FORMATION OF OPTICAL IMAGES BY X-RAYS
    KIRKPATRICK, P
    BAEZ, AV
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1948, 38 (09) : 766 - 774
  • [9] Applying X-rays in material analysis
    Kogan, V
    Bethke, K
    de Vries, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3): : 290 - 293
  • [10] Tomographic system based on Plasma Focus X-rays
    Venere, M
    Moreno, CH
    Clausse, A
    Barbuzza, R
    Del Fresno, M
    NUKLEONIKA, 2001, 46 : S93 - S94