In situ Surfactant-based Solid Phase Microextraction of p-cresol in Human Plasma Prior to HPLC Analysis

被引:3
|
作者
Samadi, Azam [1 ,2 ]
Jouyban, Abolghasem [1 ,2 ,3 ]
Amirhaghiian, Negar [4 ]
Tayebi-Khosroshahi, Hamid [5 ]
机构
[1] Tabriz Univ Med Sci, Pharmaceut Anal Res Ctr, Tabriz, Iran
[2] Tabriz Univ Med Sci, Fac Pharm, Tabriz, Iran
[3] Tabriz Univ Med Sci, Kimia Idea Pardaz Azarbayjan KIPA Sci Based Co, Tabriz 51664, Iran
[4] Tabriz Univ Med Sci, Drug Appl Res Ctr, Tabriz, Iran
[5] Tabriz Univ Med Sci, Kidney Res Ctr, Tabriz, Iran
关键词
4-methylphenol; determination; HPLC-FL; human plasma; P-cresol; surfactant based extraction; BIOANALYTICAL METHOD VALIDATION; LIQUID-CHROMATOGRAPHY; PHENOLIC-COMPOUNDS; VOLATILE PHENOLS; WATER SAMPLES; EXTRACTION;
D O I
10.2174/1573411015666190617105034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Uremia is the outcome of the remaining of nitrogenous waste products that are normally removed by the kidneys. Para-cresol (4-methylphenol) can be regarded as a proteinbound uremic toxin. The p-cresol determination in sera is necessary since it is a marker of cardiovascular risk and overall mortality in hemodialysis patients. Among the reported methods, chromatographic ones especially HPLC techniques due to the high sensitivity, selectivity and reproducibility have been extensively exploited in analysis of p-cresol in complex mixtures. However, an appropriate sample preparation prior to analysis is necessary for obtaining accurate and precise results. Methods: In this study, the appropriate precipitating agent for p-cresol determination in plasma samples was investigated. Then, in situ surfactant-based solid phase microextraction followed by HPLCFL detection was developed and validated for the quantification of p-cresol in plasma samples. Results: According to the results, HCl/heat precipitation method was used for p-cresol microextraction from from plasma samples. In situ surfactant-based solid phase microextraction using cetyltri-methylammonium bromide as extraction medium was proposed for pretreatment of plasma samples prior to analysis. The separation was achieved by isocratic elution with sodium acetate buffer (pH 3.8) and acetonitrile (20:80, v/v). Linearity was found to be acceptable over the concentration ranges of 0.5 to 8 mu g mL(-1) with the limit of detection and quantification of 0.324 and 0.422 mu g mL(-1), respectively. The variations for intra-day and inter-day precisions were both less than 8.2% and the extraction recoveries were more than 97%. Conclusion: A validated ISS-SPME followed by HPLC-FL detection reported to determine the total p-cresol concentration of human plasma samples. The traditional liquid-liquid extraction techniques are normally time consuming and require the use of large amounts of toxic organic solvents. In addition, the evaporation of extraction solvent and dissolving the analyte in the mobile phase is commonly used before HPLC analysis. Such a requirement makes the sample preparation process even more tedious and time consuming. ISS-SPME that is the developed ISS-SPE in micro scale, is a simple, rapid and effective sample preparation technique that is appropriate for HPLC-FL analysis.
引用
收藏
页码:687 / 694
页数:8
相关论文
共 50 条
  • [31] Biocompatible in-tube solid-phase microextraction coupled to HPLC for the determination of angiotensin II receptor antagonists in human plasma and urine
    Nie, J
    Zhang, M
    Fan, Y
    Wen, Y
    Xiang, BR
    Feng, YQ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 828 (1-2): : 62 - 69
  • [32] Determination of thymol in human plasma by automated headspace solid-phase microextraction-gas chromatographic analysis
    Kohlert, C
    Abel, G
    Schmid, E
    Veit, M
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 767 (01): : 11 - 18
  • [33] Application of Box-Behnken Design in the Optimization of In Situ Surfactant-Based Solid Phase Extraction Method for Spectrophotometric Determination of Quinoline Yellow in Food and Water Samples
    Hamedpour, Vahid
    Amjadi, Mohammad
    FOOD ANALYTICAL METHODS, 2014, 7 (05) : 1123 - 1129
  • [34] Biocompatible magnetite nanoparticles coated with ionic liquid-based surfactant as a hydrophilic sorbent for dispersive solid phase microextraction of cephalosporins prior to their quantitation by HPTLC
    Farrag, A. Sherien
    Rageh, H. Azza
    Askal, F. Hassan
    Saleh, A. Gamal
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1205
  • [35] Rapid analysis of captopril in human plasma and pharmaceutical preparations by headspace solid phase microextraction based on polypyrrole film coupled to ion mobility spectrometry
    Karimi, Akarm
    Alizadeh, Naader
    TALANTA, 2009, 79 (02) : 479 - 485
  • [36] Automated on-line in-tube solid-phase microextraction coupled with HPLC/MS/MS for the determination of butyrophenone derivatives in human plasma
    Takeshi Kumazawa
    Koichi Saeki
    Isao Yanagisawa
    Seisaku Uchigasaki
    Chika Hasegawa
    Hiroshi Seno
    Osamu Suzuki
    Keizo Sato
    Analytical and Bioanalytical Chemistry, 2009, 394 : 1161 - 1170
  • [37] Automated on-line in-tube solid-phase microextraction coupled with HPLC/MS/MS for the determination of butyrophenone derivatives in human plasma
    Kumazawa, Takeshi
    Saeki, Koichi
    Yanagisawa, Isao
    Uchigasaki, Seisaku
    Hasegawa, Chika
    Seno, Hiroshi
    Suzuki, Osamu
    Sato, Keizo
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 394 (04) : 1161 - 1170
  • [38] Coupling of solid phase microextraction with electrospray ionization ion mobility spectrometry and direct analysis of venlafaxine in human urine and plasma
    Jafari, Mohammad T.
    Saraji, Mohammad
    Ameri, Amir H.
    ANALYTICA CHIMICA ACTA, 2015, 853 : 460 - 468
  • [39] HPLC analysis of the novel antidepressant duloxetine in human plasma after an original solid-phase extraction procedure
    Mercolini, Laura
    Mandrioli, Roberto
    Cazzolla, Roberto
    Amore, Mario
    Raggi, Maria Augusta
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 856 (1-2): : 81 - 87
  • [40] Homogenous dispersive solid phase extraction combined with ionic liquid based-dispersive liquid–liquid microextraction of gentamicin and streptomycin from milk prior to HPLC-MS/MS analysis
    Abolghasem Jouyban
    Mahboob Nemati
    Mir Ali Farajzadeh
    Jafar Soleymani
    Mohammad Reza Afshar Mogaddam
    Journal of the Iranian Chemical Society, 2022, 19 : 4309 - 4316