An experimental study on the digital precision of internal fixation via the sinus tarsi approach for calcaneal fractures

被引:5
|
作者
Xu, Jing [1 ]
He, Zaopeng [2 ]
Zhang, Guodong [3 ]
Chen, Yongshao [4 ]
Wei, Chunrong [2 ]
Zheng, Yudong [2 ]
Lin, Haibin [3 ]
Li, Wei [2 ]
Huang, Wenhua [1 ]
机构
[1] Southern Med Univ, Sch Basic Med Sci, Natl Key Discipline Human Anat, 1838 Guangzhou Rd North, Guangzhou 510515, Guangdong, Peoples R China
[2] Guangzhou Med Univ, Affiliated Shunde Hosp, Hand & Foot Surg & Plast Surg, A163,Middle Rd, Foshan 528315, Gudong Province, Peoples R China
[3] Putian Univ, Affiliated Hosp, Dept Orthoped, Putian City, Peoples R China
[4] Guangzhou Med Univ, Affiliated Shunde Hosp, Foshan, Peoples R China
基金
国家重点研发计划;
关键词
Calcaneal fracture; internal fixation; locking bone plate; 3-D printing; navigation; EXTENSILE LATERAL APPROACH; DISPLACED INTRAARTICULAR FRACTURES; SUSTENTACULUM-TALI; ANATOMICAL PLATE; PLACEMENT; SCREWS; METAANALYSIS; MANAGEMENT; TEMPLATES;
D O I
10.1177/2309499019834072
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To investigate the effectiveness and accuracy of internal fixation of calcaneal fractures with a three-dimensional (3-D) printing navigation module via the sinus approach. Methods: Eleven lateral lower extremity specimens were used in the experiment and divided into the digital design (DD) group (n = 11) and the real surgery (RS) group (n = 11). For the DD group, thin-section computed tomography (CT) scans, virtual fracture modeling, virtual bone plate fixation, sinus occlusal module design, and navigation module design were performed for the cadaver specimens. A 3-D navigation module was printed using a 3-D printer. For the RS group, the sinus approach incision was made, and the navigation module was used to assist the placement of screw fixation and anatomically locked bone plate fixation. Thin-layer CT scans, 3-D reconstructions, and reconstruction of the nail paths were performed in the RS group and 3-D registered with the DD group. 3-D coordinate values for the screw entry and exit points in the RS and DD groups were recorded, and the corresponding offset values of the screw points were calculated. The number of qualified nails at different accuracy levels was counted. The chi(2) test was used to compare the data for the DD and RS groups to obtain the accuracy level for both groups when p > 0.05, which is the critical value for experimental accuracy. Results: A total of 11 bone plates were placed and 120 screws were locked. None of them protruded from the inferior articular surface. The screw entry and exit point offsets were 1.71 +/- 0.11 mm and 3.10 +/- 0.19 mm, respectively. When the accuracy requirement for the entry point was 3.8 mm, there was no statistically significant difference between the two groups (p > 0.05). Similarly, the accuracy of the exit point of the screw could only reach 6.6 mm. Conclusion: Internal fixation of calcaneal fractures via the sinus tarsi approach with an anatomical locking plate based on the 3-D printing navigation module can achieve accurate screw placement and good overall internal fixation.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] A minimally invasive (sinus tarsi) approach with percutaneous K-wires fixation for intra-articular calcaneal fractures in children
    Tong, Lei
    Li, Mingjing
    Li, Fan
    Xu, Jian
    Hu, Tao
    JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2018, 27 (06): : 556 - 562
  • [42] Surgical Technique and Algorithm for Treatment of Displaced Intra-articular Calcaneal Fractures Using a Sinus Tarsi Approach and Plate Fixation
    Fuentes, Eduardo
    Nunez, Matias
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2019, 18 (03): : 141 - 148
  • [43] Surgical Technique and Algorithm for the Treatment of Closed and Displaced Intra-articular Calcaneal Fractures by the Sinus Tarsi Approach and Plate Fixation
    Fuentes, Eduardo M.
    Staub, Ricardo F.
    Cataldo, Mauricio M.
    Ibacache, Rodrigo F.
    TECHNIQUES IN FOOT AND ANKLE SURGERY, 2014, 13 (03): : 150 - 157
  • [44] Minimally invasive treatment of calcaneal fractures via the sinus tarsi approach based on a 3D printing technique
    Yao, Lufeng
    Wang, Haiqing
    Zhang, Feng
    Wang, Liping
    Dong, Jianghui
    MATHEMATICAL BIOSCIENCES AND ENGINEERING, 2019, 16 (03) : 1597 - 1610
  • [45] Sinus Tarsi Approach for Calcaneus Fractures
    Gonzalez, Tyler A.
    Kwon, John Y.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2015, 25 (04) : 235 - 241
  • [46] Extended Sinus Tarsi Approach for Treatment of Displaced Intraarticular Calcaneal Fractures Compared to Extended Lateral Approach
    Song, Jae Hwang
    Kang, Chan
    Hwang, Deuk Soo
    Kang, Dong Hun
    Park, June Woo
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (02) : 167 - 177
  • [47] Management of displaced intra-articular calcaneal fractures using the limited open sinus tarsi approach and fixation by screws only technique
    Abdelazeem, Ahmed
    Khedr, Ahmed
    Abousayed, Mostafa
    Seifeldin, Ahmed
    Khaled, Sherif
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (03) : 601 - 606
  • [48] Extensive lateral versus tarsal sinus approach to internal fixation for intra-articular calcaneal fractures
    Jia, Bin
    Li, Wei
    Liu, Yanxun
    Tu, Yihong
    Xu, Guangjian
    Peng, Hao
    Luo, Huan
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (11): : 15782 - 15788
  • [49] Surgical Treatment of Sanders Type 2 Calcaneal Fractures Using a Sinus Tarsi Approach Reply
    Park, Chul Hyun
    Lee, Dong Yeol
    INDIAN JOURNAL OF ORTHOPAEDICS, 2018, 52 (02) : 210 - U128
  • [50] Implant Choice and Outcomes of the Sinus Tarsi Approach for Displaced Intra-articular Calcaneal Fractures
    Eelsing, Robin
    Aronius, Loran B.
    Halm, Jens A.
    Schepers, Tim
    FOOT & ANKLE INTERNATIONAL, 2023, 44 (08) : 738 - 744