Flap complications in our learning curve of laser in situ keratomileusis using the Hansatome microkeratome

被引:14
|
作者
Yildirim, R [1 ]
Devranoglu, K [1 ]
Ozdamar, A [1 ]
Aras, C [1 ]
Ozkiris, A [1 ]
Ozkan, S [1 ]
机构
[1] Istanbul Univ, Cerrahpasa Med Sch, Dept Ophthalmol, Istanbul, Turkey
关键词
LASIK; microkeratome; flap complication;
D O I
10.1177/112067210101100402
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To determine the incidence and the type of flap complications in our initial series of eyes undergoing laser in situ keratomileusis and the impact of microkeratome-related complications on best spectacle-corrected visual acuity. METHODS. We reviewed the charts of the 630 consecutive eyes operated in the Refractive Surgery Department of Cerrahpasa Medical School, University of Istanbul, Turkey using the Hansatome microkeratome and the Summit, SVS Apex Plus excimer laser between March 1998 and November 1999. The mean follow-up was 12.6 months. RESULTS. The incidence of total flap complications was 19.8%. Flap folds (5%) were the most common complication. The incidence of epithelial ingrowth was 3.3%. Diffuse lamellar keratitis was encountered in 20 cases (3.17%), Displaced flaps were seen shortly after the procedure in 8 eyes (1.26%) and repositioned immediately. Improper keratectomy occurred in 14 eyes (2.2%) and incomplete keratectomy in four procedures (0.63%). The presence of interface debris and hemorrhage was each 1.9%. We observed one interface abscess, which was culture-negative and cured with fortified antibiotics, and one free flap. CONCLUSIONS. Although the LASIK procedure with the Hansatome had an easy learning curve without any of the serious complications that frequently occur in this phase, we still observed flap related complications that affected visual outcome.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 50 条
  • [21] Intraindividual comparison of epithelial defects during laser in situ keratomileusis using standard and zero-compression Hansatome microkeratome heads
    Kohnen, T
    Terzi, E
    Mirshahi, A
    Bühren, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01): : 123 - 126
  • [22] Femtosecond-Assisted Laser in situ Keratomileusis with de novo Flap Creation Following Previous Microkeratome Laser in situ Keratomileusis
    Rush, Sloan W.
    Rush, Ryan B.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 1813 - 1818
  • [23] Femtosecond-Assisted Laser in situ Keratomileusis with De Novo Flap Creation Following Previous Microkeratome Laser in situ Keratomileusis
    Srirampur, Arjun
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2933 - 2934
  • [24] Incidence of intraoperative flap complications in laser in situ keratomileusis
    Jacobs, JM
    Taravella, MJ
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (01): : 23 - 28
  • [25] Intraoperative microkeratome complications in 47,094 laser in situ keratomileusis surgeries
    Nakano, K
    Nakano, E
    Oliveira, M
    Portellinha, W
    Alvarenga, L
    JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (05) : S723 - S726
  • [26] Corneal flap measurements in laser in situ keratomileusis using the Moria M2 automated microkeratome
    Pietilä, J
    Mäkinen, P
    Suominen, S
    Huhtala, A
    Uusitalo, H
    JOURNAL OF REFRACTIVE SURGERY, 2005, 21 (04) : 377 - 385
  • [27] Blade source effect on laser in situ keratomileusis flap thickness with the Amadeus I microkeratome
    Ruth, Adrienne L.
    Lynn, Michael J.
    Randleman, J. Bradley
    Stulting, R. Doyle
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 407 - 410
  • [28] Factors affecting laser in situ keratomileusis flap thickness: Comparison of 2 microkeratome heads
    Mimouni, Michael
    Nemet, Arie Y.
    Levartovsky, Shmuel
    Sela, Tzahi
    Munzer, Gur
    Kaiserman, Igor
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02): : 348 - 353
  • [29] Microbial cultures of the microkeratome blade immediately after flap construction in laser in situ keratomileusis
    Khan, Ahsan M.
    Larson, Bruce
    Noth, James
    Rosen, Roger
    Bouchard, Charles
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (05): : 842 - 845
  • [30] Influence of microkeratome parameters on the stromal bed and flap edge quality in laser in situ keratomileusis
    Heichel, Jens
    Wilhelm, Frank
    Kunert, Kathleen S.
    Schlueter, Rabea
    Stuhltraeger, Ute
    Hammer, Thomas
    CLINICAL OPHTHALMOLOGY, 2014, 8 : 61 - 69