Detection of tricyclic antidepressants in whole blood by headspace solid-phase microextraction and capillary gas chromatography

被引:65
|
作者
Lee, XP
Kumazawa, T
Sato, K
Suzuki, O
机构
[1] SHOWA UNIV, SCH MED, DEPT LEGAL MED, SHINAGAWA KU, TOKYO 142, JAPAN
[2] HAMAMATSU UNIV SCH MED, DEPT LEGAL MED, HAMAMATSU, SHIZUOKA 43131, JAPAN
关键词
D O I
10.1093/chromsci/35.7.302
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple method for the extraction of four tricyclic antidepressants from whole blood by headspace solid-phase microextraction (SPME) is presented. The whole blood samples contain four drugs (amitriptyline, chlorimipramine, imipramine, and trimipramine) and are heated at 100°C in a septum-capped vial in the presence of distilled water and NaOH solution; a polydimethylsiloxane-coated SPME fiber is exposed to the headspace of the vial to allow adsorption of the drugs before capillary gas chromatography (GC) with flame-ionization detection. The headspace SPME-GC produces intense peaks for each drug with very little background noise. Recoveries of the four drugs by the present method are 5.3-12.9%. The calibration curves for the drugs show linearity in the range of 31-1000 ng/0.5 ml. The detection limits of each drug are 16-25 ng/0.5 mL. Imipramine is detectable from rat blood 5 h after oral administration of imipramine (500 mg/kg body weight); the concentration is 1.44 ± 0.209 μg/mL.
引用
收藏
页码:302 / 308
页数:7
相关论文
共 50 条
  • [1] Analysis of cyanide in blood by headspace solid-phase microextraction (SPME) and capillary gas chromatography
    Takekawa, K
    Oya, M
    Kido, A
    Suzuki, O
    CHROMATOGRAPHIA, 1998, 47 (3-4) : 209 - 214
  • [2] Analysis of cyanide in blood by headspace solid-phase microextraction (SPME) and capillary gas chromatography
    K. Takekawa
    M. Oya
    A. Kido
    O. Suzuki
    Chromatographia, 1998, 47 : 209 - 214
  • [3] Determination of cyanide and volatile alkylnitriles in whole blood by headspace solid-phase microextraction and gas chromatography with nitrogen phosphorus detection
    Boadas-Vaello, Pere
    Jover, Eric
    Llorens, Jordi
    Bayona, Josep M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 870 (01): : 17 - 21
  • [4] Determination of ethanol in human blood and urine by automated headspace solid-phase microextraction and capillary gas chromatography
    De Martinis, BS
    Ruzzene, MAM
    Martin, CCS
    ANALYTICA CHIMICA ACTA, 2004, 522 (02) : 163 - 168
  • [5] Detection of perfluorocarbons in blood by headspace solid-phase microextraction combined with gas chromatography/mass spectrometry
    Mathurin, JC
    de Ceaurriz, J
    Audran, M
    Krafft, MP
    BIOMEDICAL CHROMATOGRAPHY, 2001, 15 (07) : 443 - 451
  • [6] Detection of perfluorocarbons in blood by headspace solid-phase microextraction combined with gas chromatography/mass spectrometry
    Mathurin, Jean-Charles
    De Ceaurriz, Jacques
    Audran, Michel
    Krafft, Marie-Pierre
    2001, John Wiley and Sons Ltd (15)
  • [7] Static headspace, solid-phase microextraction and headspace solid-phase microextraction for BTEX determination in aqueous samples by gas chromatography
    Menéndez, JCF
    Sánchez, MLF
    Uría, JES
    Martínez, EF
    Sanz-Medel, A
    ANALYTICA CHIMICA ACTA, 2000, 415 (1-2) : 9 - 20
  • [8] Automated headspace solid-phase microextraction and capillary gas chromatography analysis of ethanol in postmortem specimens
    De Martinis, BS
    Martin, CCS
    FORENSIC SCIENCE INTERNATIONAL, 2002, 128 (03) : 115 - 119
  • [9] Analysis of wine bouquet components using headspace solid-phase microextraction capillary gas chromatography
    Garcia, DDLC
    Reichenbaher, M
    Denzer, K
    Hurlbeck, C
    Bartzsch, C
    Feller, KH
    HRC-JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY, 1998, 21 (07): : 373 - 377
  • [10] Optimization of wine headspace analysis by solid-phase microextraction capillary gas chromatography with mass spectrometric and flame ionization detection
    Tat, L
    Comuzzo, P
    Stolfo, I
    Battistutta, F
    FOOD CHEMISTRY, 2005, 93 (02) : 361 - 369