Dose assessment and reconstruction algorithm optimization in simultaneous breast and lung CT imaging.

被引:1
|
作者
Antonio, Debora [1 ,2 ,3 ]
Di Maria, Salvatore [2 ]
Matela, Nuno [3 ]
Vieira, Sandra [4 ]
Vaz, Pedro [2 ]
机构
[1] Univ Nova Lisboa, Fac Ciencias & Tecnol, Dept Fis, P-2829516 Quinta Da Torre, Caparica, Portugal
[2] Univ Lisbon, Ctr Ciencias & Tecnol Nucl, Inst Super Tecn, Estr Nacl 10,Km139,7, P-2695066 Bobadela, Portugal
[3] Univ Lisbon, Fac Ciencias, Inst Biofis & Engn Biomed, P-1749016 Lisbon, Portugal
[4] Ctr Clin Champalimaud, Radioncol, Ave Brasilia, P-1400038 Lisbon, Portugal
关键词
Cone beam computed tomography; Cancer detection; Monte Carlo simulation; Organ dose; Medical image reconstruction; Lung and breast imaging; X-RAY-SPECTRA; CANCER; TOMOSYNTHESIS;
D O I
10.1016/j.radphyschem.2020.108972
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cancer is the second leading cause of death in the world, and therefore, there is an undeniable need to ensure early screening and detection systems worldwide. The aim of this project was to study the feasibility of a Cone Beam Computed Tomography (CBCT) scanner for simultaneous breast and lung lesion imaging. Additionally, the development of reconstruction algorithms and the study of their impact to the image quality was considered. Monte Carlo (MC) simulations were performed using the PENELOPE code system. A geometry model of a CBCT scanner was implemented for energies of 30 keV and 80 keV for hypothetical scanning protocols. Microcalcifications were inserted into the breast and lung of the computational phantom (ICRP Adult Female Reference), used in the simulations for dose assessment and projection acquisition. Dosimetric and imaging performances were evaluated through Computed Tomography Dose Index and Catphan phantoms, respectively. Reconstructed images were analyzed in terms of Contrast-to-Noise Ratio (CNR) and dose calculations were performed for two protocols, using a normalization factor of 2 mGy in the breast and another with 5 mGy in the lungs. MC geometry model and reconstruction algorithm were validated by means of on-field measurements and data acquisition in a clinical center. Results indicate that for both protocols, the absorbed dose in both organs is the same, allowing the optimization of protocol strategies regarding radiosensitive organs. The best implementation of the reconstruction algorithm was achieved with 80 keV, using linear interpolation and hanning filter. More specifically for a spherical lung lesion (r = 7 mm) a 30% CNR gain was found when the number of projections varied from 12 to 36 (corresponding to a dose increase of a factor of 3). This study suggests the applicability of a CBCT modulated beam scanner for imaging simultaneously breast and lung lesions while ensuring dose reduction without compromising image quality as a possibility.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Optimization of a customized Simultaneous Algebraic Reconstruction Technique algorithm for breast CT
    Donato, Sandro
    Brombal, Luca
    Arfelli, Fulvia
    Fanti, Viviana
    Longo, Renata
    Oliva, Piernicola
    Rigon, Luigi
    Golosio, Bruno
    2019 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2019,
  • [2] Evaluation of COSEM, a new iterative reconstruction algorithm for coincidence imaging.
    Patton, JA
    Shai, E
    Wilk, M
    Harden, G
    Sandler, MP
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 294P - 294P
  • [3] Lung nodules assessment in ultra-low-dose CT with iterative reconstruction compared to conventional dose CT
    Jin, Shiqi
    Zhang, Bo
    Zhang, Lina
    Li, Shu
    Li, Songbai
    Li, Peiling
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (05) : 480 - 490
  • [4] Evaluation of a wide beam reconstruction algorithm for dose reduction in molecular breast imaging
    Weinmann, Amanda
    Hruska, Carrie
    O'Connor, Michael
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53
  • [5] Point/counterpoint: dose-related issues in cardiac CT imaging.
    Newman B.
    Vasanawala S.S.
    Pediatric Radiology, 2011, 41 (Suppl 2) : 528 - 533
  • [6] Characterization of the Effect of 'Lung Detail' CT Reconstruction Algorithm On Radiation Therapy Dose Calculation
    Eclov, N.
    Loo, B.
    Graves, E.
    Maxim, P.
    MEDICAL PHYSICS, 2012, 39 (06) : 3693 - 3693
  • [7] Image quality assessment of an iterative reconstruction algorithm applied to abdominal CT imaging
    Funama, Yoshinori
    Taguchi, Katsuyuki
    Utsunomiya, Daisuke
    Oda, Seitaro
    Katahira, Kazuhiro
    Tokuyasu, Shinichi
    Yamashita, Yasuyuki
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (04): : 527 - 534
  • [8] Low-dose CT scans for CT-based attenuation correction in PET/CT imaging.
    Bai, C
    Shao, L
    Da Silva, AJ
    Zhao, Z
    Hines, H
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 104P - 105P
  • [9] Effects of CT attenuation correction and reconstruction method on myocardial SPECT perfusion imaging.
    Naum, A. G.
    Biermann, M.
    Johnsen, B.
    Husby, J. Aase
    Bach-Gansmo, T.
    Rotevatn, S.
    Nordrehaug, J. E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 : S285 - S286
  • [10] Phase-Contrast Clinical Breast CT: Optimization of Imaging Setups and Reconstruction Workflows
    Tromba, Giuliana
    Pacile, Serena
    Nesterets, Yakov I.
    Brun, Francesco
    Dullin, Christian
    Dreossi, Diego
    Mayo, Sheridan C.
    Stevenson, Andrew W.
    Pavlov, Konstantin M.
    Kitchen, Markus J.
    Thompson, Darren
    Brown, Jeremy M. C.
    Lockie, Darren
    Tonutti, Maura
    Stacul, Fulvio
    Zanconati, Fabrizio
    Accardo, Agostino
    Gureyev, T. E.
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 625 - 634