In vivo repeatability and reproducibility of the quantitative light-induced fluorescence method

被引:54
|
作者
Tranæus, S [1 ]
Shi, XQ [1 ]
Lindgren, LE [1 ]
Trollsås, K [1 ]
Angmar-Månsson, B [1 ]
机构
[1] Karolinska Inst, Inst Odontol, Dept Cariol & Endodontol, SE-14104 Huddinge, Sweden
关键词
caries; clinical detection; repeatability; reproducibility; quantitative light-induced fluorescence quantification;
D O I
10.1159/000057583
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
In vivo repeatability and reproducibility of the quantitative light-induced fluorescence (QLF) method were tested with respect to three variables: lesion area, and average and maximum changes in lesion fluorescence. To test the image-capturing stages, three analysts each captured images of 15 incipient smooth surface lesions in vivo, and the images were analysed by one of the analysts. To test the analytical stage of the method, three analysts analysed the images of 15 in vivo incipient smooth surface lesions. For the image-capturing stage, inter-examiner reliability showed an intra-class correlation coefficient (r) between 0.95 and 0.98. For the analytical stage, intra-examiner reliability for all three analysts showed a value of r between 0.93 and 0.99. Inter-examiner reliability showed a value of r between 0.95 and 0.99. It was concluded that the in vivo repeatability and reproducibility of the QLF method are excellent. Copyright (C) 2002 S. Karger AG, Basel.
引用
收藏
页码:3 / 9
页数:7
相关论文
共 50 条
  • [21] Early detection of secondary caries using quantitative, light-induced fluorescence
    González-Cabezas, C
    Fontana, M
    Gomes-Moosbauer, D
    Stookey, GK
    OPERATIVE DENTISTRY, 2003, 28 (04) : 415 - 422
  • [22] Quantitative light-induced fluorescence: A potential tool for general dental assessment
    Amaechi, BT
    Higham, SM
    JOURNAL OF BIOMEDICAL OPTICS, 2002, 7 (01) : 7 - 13
  • [23] Detection of initial caries lesions on smooth surfaces by quantitative light-induced fluorescence and visual examination:: an in vivo comparison
    Heinrich-Weltzien, R
    Kühnisch, J
    Ifland, S
    Tranæus, S
    Angmar-Månsson, B
    Stösser, L
    EUROPEAN JOURNAL OF ORAL SCIENCES, 2005, 113 (06) : 494 - 498
  • [24] Orange/Red Fluorescence of Active Caries by Retrospective Quantitative Light-Induced Fluorescence Image Analysis
    Gomez, Grace Felix
    Eckert, George J.
    Zandona, Andrea Ferreira
    CARIES RESEARCH, 2016, 50 (03) : 295 - 302
  • [25] Quantitative light-induced fluorescence (QLF): A tool for early occlusal dental caries detection and supporting decision making in vivo
    Alammari, M. R.
    Smith, P. W.
    de Jong, E. de Josselin
    Higham, S. M.
    JOURNAL OF DENTISTRY, 2013, 41 (02) : 127 - 132
  • [26] Assessment of non-cavitated root caries lesions by quantitative light-induced fluorescence-An in vivo feasibility study
    Guenther, Elena
    Park, Kyung-Jin
    Meissner, Thomas
    Kottmann, Tanja
    Schmalz, Gerhard
    Haak, Rainer
    Ziebolz, Dirk
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 30
  • [27] In vivo detection of non-cavitated caries lesions on occlusal surfaces by visual inspection and quantitative light-induced fluorescence
    Kuehnisch, Jan
    Ifland, Susanne
    Tranaeus, Sofia
    Hickel, Reinhard
    Stoesser, Lutz
    ACTA ODONTOLOGICA SCANDINAVICA, 2007, 65 (03) : 183 - 188
  • [28] In Vivo Performance of Visual Criteria, Laser-Induced Fluorescence, and Light-Induced Fluorescence for Early Caries Detection
    Perdiou, Antonis
    Fratila, Aurora Doris
    Sava-Rosianu, Ruxandra
    Alexa, Vlad Tiberiu
    Lalescu, Dacian
    Jumanca, Daniela
    Galuscan, Atena
    DIAGNOSTICS, 2023, 13 (20)
  • [29] Light-induced fluorescence endoscopy (LIFE) for the in vivo detection of colorectal dysplasia.
    Haringsma, J
    Tytgat, GNJ
    GASTROENTEROLOGY, 1998, 114 (04) : A606 - A606
  • [30] Quantitative light-induced fluorescence to measure demineralisation around orthodontic brackets.
    Benson, PE
    Pender, N
    Higham, SM
    JOURNAL OF DENTAL RESEARCH, 2001, 80 (04) : 1150 - 1150