Conventional versus 3D ultrasound for the investigation of infertile women

被引:0
|
作者
Zvanca, Mona [1 ]
Vladareanu, Radu [1 ]
Kurjak, Asim [2 ]
Al Bahar, Awatif Juma [3 ,4 ]
机构
[1] Elias Emergency Hosp, Dept Obstet & Gynecol, Bucharest 020322, Romania
[2] Univ Zagreb, Sch Med, Sveti Duh Hosp, Dept Obstet & Gynecol, Zagreb 41001, Croatia
[3] Al Wasl Hosp, Dept Hlth, Dubai, U Arab Emirates
[4] Al Wasl Hosp, Med Serv, Dubai, U Arab Emirates
关键词
Female infertility; Three-dimensional ultrasound; Conventional ultrasound;
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: With the technical development, ultrasound tends to overpass its limits and to become the main investigation tool even for situations when it was traditionally considered "second best". It is more convenient both for patient and doctor, less expensive and has real diagnostic value. Objective: The present paper, and its graphic back-up, are intended as a visual testimony of the fact that the newer three dimensional (3D) ultrasound technique is much more than a simple generator of "nice", commercial, images. Moreover, its use may be extended from obstetrics to gynecological pathology, especially in cases related to infertility. Materials and Methods: We performed a review of the main local infertility causes and their perception by the 3D ultrasound, as compared to the conventional methods. General literature citations were completed with personal cases and images. In our research, we used a Kretz-Voluson Expert 730 ultrasound machine with a full logistic equipment. Our database was completed over a period of 18 months and included various pathology, such as uterine anomalies, fibroids, polyps, ovarian cysts and many others. Results: Three dimensional ultrasound represents the best tool in evaluating the uterine cavity, the endometrium, assessing its volume and vascularity pattern. It also offers a very good image of the uterine structure, the adnexal morphology and their relationship. It performs a thorough pelvic assessment by a single examination. Moreover, it may realize a histerosalpingography, which is as efficient as the radiological method, but easier and with fewer side effects. Conclusion: Even though it is technically more difficult and time consuming, a good practice and high quality ultrasound equipment offer a series of benefits over any other kind of investigation.
引用
收藏
页码:109 / 117
页数:9
相关论文
共 50 条
  • [21] Investigation of 3D Reconstruction Algorithms For Wireless Freehand Ultrasound Imaging System
    Zhao, Lanxi
    Song, Sheng
    Zhang, Chunlei
    Huang, Peng
    Zhang, Yi
    Zhang, Mingbo
    Zheng, Rui
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,
  • [22] MIMO Arrays Versus Conventional Thin Arrays for 2D and 3D Radar Applications
    Mietzner, Jan
    2017 EUROPEAN RADAR CONFERENCE (EURAD), 2017, : 110 - 113
  • [23] Undiagnosed Endometrial Abnormalities in Women Scheduled for IVF: Comparing Accuracy of 3D Ultrasound (US) Versus Vaginoscopic Hysteroscopy (VH)
    Abdelmagied, Ahmed M.
    Kamel, Momen A.
    Stewart, Elizabeth A.
    AboElHassan, Ahmed M.
    Makarem, Mohamed H.
    REPRODUCTIVE SCIENCES, 2015, 22 : 216A - 216A
  • [24] COMPARISON OF 3D/4D ULTRASOUND TO 3D SALINE INFUSED SONOHYSTEROGRAPHYFOR EVALUATION OF ENDOMETRIAL POLYPS IN PRE AND POSTMENOPAUSAL WOMEN
    Rodriguez B, M. A.
    Gualtieri, M.
    Mouhayar, Y.
    Mejia, A.
    Brookfield, K. F.
    Cruz-Pachano, F.
    FERTILITY AND STERILITY, 2012, 98 (03) : S39 - S39
  • [25] 3D Ultrasound Evaluation of the Fetal Ear - Comparison of an xMatrix Probe with a Conventional Mechanical Probe
    Buerkel, Kai
    Kraemer, Ursula
    Moellers, Mareike
    Falkenberg, Maria Karina
    Klockenbusch, Walter
    Schmitz, Ralf
    ULTRASCHALL IN DER MEDIZIN, 2017, 38 (05): : 508 - 514
  • [26] 3-dimensional ultrasound as a single step for evaluation of infertile women.
    Ali, AFM
    Hamed, WM
    Shalabi, HS
    AbdelRahman, AE
    FERTILITY AND STERILITY, 2002, 78 (03) : S93 - S93
  • [27] Sonohysterography accuracy versus transvaginal ultrasound in infertile women candidate to assisted reproduction techniques.
    Vilela, Joao Rocha
    de Oliveira Cardoso, Maria Teresinha
    Franco Junior, Jose Goncalves
    Pontes, Anagloria
    REVISTA BRASILEIRA DE GINECOLOGIA E OBSTETRICIA, 2012, 34 (03): : 122 - 127
  • [28] Blind aspiration biopsy versus a guided hysteroscopic technique for investigation of the endometrium in infertile women
    Ejzenberg, Dani
    Simoes, Manuel de Jesus
    Pinheiro, Walter
    Soares Junior, Jose Maria
    Serafini, Paulo Cesar
    Baracat, Edmund Chada
    HISTOLOGY AND HISTOPATHOLOGY, 2016, 31 (09) : 981 - 986
  • [29] Speckle detection for 3D ultrasound
    Carmo, BS
    Prager, RW
    Gee, AH
    Berman, LH
    ULTRASONICS, 2002, 40 (1-8) : 129 - 132
  • [30] 3D ultrasound in early pregnancy
    Exalto, N.
    Koning, A.
    Steegers, E.
    HUMAN REPRODUCTION, 2016, 31 : 60 - 61