Relationship between Abdominal Circumference and Incidence of Hypotension during Cesarean Section under Spinal Anesthesia

被引:0
|
作者
Thomard, Pattaraleeya [1 ]
Morakul, Sunthiti [1 ]
Wirachpisit, Nichawan [1 ]
Ittichaikulthol, Wichai [1 ]
Pisitsak, Chawika [1 ]
机构
[1] Mahidol Univ, Ramathibodi Hosp, Fac Med, Dept Anesthesiol, Salaya, Nakhon Pathom, Thailand
关键词
CEREBROSPINAL-FLUID VOLUME; INTRAABDOMINAL PRESSURE; LEVEL; BLOCK; SPREAD; LENGTH; SPACE;
D O I
10.1155/2020/6547927
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Enlarged uterus can compress the inferior vena cava and cause hypotension when lying supine. Previous studies have shown a positive association between the abdominal circumference and size of the uterus. Therefore, the aim of this study was to evaluate the relationship between abdominal circumference and incidence of hypotension during cesarean section under spinal anesthesia.Methods. The study cohort comprised women undergoing cesarean section under spinal anesthesia. Patients were divided into two groups according to the median abdominal circumference (<101 cm and >= 101 cm). Hypotension was defined as a systolic blood pressure of Results. The study cohort comprised 100 women. The incidence of hypotension did not differ between the groups (71.42% in the smaller vs. 78.43% in the larger abdominal circumference group,p=0.419). However, the decrease in mean arterial pressure and its percentage decrease from baseline were greater in the larger than in the smaller abdominal circumference group (change in mean arterial pressure: 28.33 mmHg (18.66-33.67) in the smaller vs. 36.67 mmHg (23.34-43.34) in the larger abdominal circumference group,p=0.004; percentage decrease: 31.41% (22.74-39.22) in the smaller vs. 38.47% (28.00-44.81) in the larger abdominal circumference group,p=0.022).Conclusions. Large abdominal circumference in pregnancy is associated with greater decreases in mean arterial pressure from baseline. However, the incidence of hypotension defined by standard criteria did not differ between larger and smaller abdominal circumference groups.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Consensus on the Southeast Asian management of hypotension using vasopressors and adjunct modalities during cesarean section under spinal anesthesia
    Herbosa G.A.B.
    Tho N.N.
    Gapay A.A.
    Lorsomradee S.
    Thang C.Q.
    Journal of Anesthesia, Analgesia and Critical Care, 2 (1):
  • [32] Changing trends in the management of hypotension following spinal anesthesia in cesarean section
    Mitra, J. K.
    Roy, J.
    Bhattacharyya, P.
    Yunus, M.
    Lyngdoh, N. M.
    JOURNAL OF POSTGRADUATE MEDICINE, 2013, 59 (02) : 121 - 126
  • [33] Effect of injection rate on hypotension associated with spinal anesthesia for cesarean section
    Simon, L
    Boulay, G
    Ziane, AF
    Noblesse, E
    Mathiot, JL
    Toubas, MF
    Hamaza, J
    INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2000, 9 (01) : 10 - 14
  • [34] PREVENTION OF HYPOTENSION FOLLOWING SPINAL-ANESTHESIA FOR CESAREAN-SECTION
    ROUT, CC
    ROCKE, DA
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1994, 32 (02) : 117 - 135
  • [35] Effect of eNOS genetic polymorphism on hypotension and treatment response during spinal anesthesia for cesarean section
    Landau, R
    Negron, M
    Blouin, J
    Scott, JA
    Smiley, RM
    ANESTHESIOLOGY, 2004, 100 (05) : B33 - B33
  • [36] Comparison of an ephedrine infusion with lidocaine %5 for prevention of hypotension during spinal anesthesia in cesarean section
    Pouryaghobi, Seyyed Mohsen
    Mashak, Banafsheh
    Kabir, Kourosh
    Hajimaghsoudi, Leila
    Ahmadinejad, Mojtaba
    ANNALS OF MEDICINE AND SURGERY, 2022, 73
  • [37] METHOD OF EPHEDRINE ADMINISTRATION AND NAUSEA AND HYPOTENSION DURING SPINAL-ANESTHESIA FOR CESAREAN-SECTION
    DATTA, S
    ALPER, MH
    OSTHEIMER, GW
    WEISS, JB
    ANESTHESIOLOGY, 1982, 56 (01) : 68 - 70
  • [38] THE INCIDENCE AND NEONATAL EFFECTS OF MATERNAL HYPOTENSION DURING EPIDURAL-ANESTHESIA FOR CESAREAN-SECTION
    BRIZGYS, RV
    DAILEY, PA
    SHNIDER, SM
    KOTELKO, DM
    LEVINSON, G
    ANESTHESIOLOGY, 1987, 67 (05) : 782 - 786
  • [39] Ondansetron in the prevention of pruritus during elective cesarean section under spinal anesthesia
    Dubuc, M
    Crochetière, C
    Villeneuve, E
    ANESTHESIOLOGY, 2001, 94 (1A)
  • [40] Effects of colloid preload on the incidence of hypotension in spinal anesthesia for cesarean section: a systematic review and meta-analysis
    Gong Rui-Song
    Liu Xiao-Wen
    Li Wei-Xia
    Zhao Jing
    中华医学杂志(英文版), 2021, 134 (09) : 1043 - 1051