3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer

被引:85
|
作者
Gandolfi, M. G. [1 ]
Parrilli, A. P. [2 ]
Fini, M. [2 ]
Prati, C. [1 ,3 ]
Dummer, P. M. H. [4 ]
机构
[1] Univ Bologna, Dept Odontostomatol Sci, Lab Biomat & Oral Pathol, Bologna, Italy
[2] Rizzoli Orthopaed Inst, Lab Preclin & Surg Studies, Bologna, Italy
[3] Univ Bologna, Dept Odontostomatol Sci, Endodont Clin Sect, Bologna, Italy
[4] Cardiff Univ, Sch Dent, Cardiff CF10 3AX, S Glam, Wales
关键词
3D micro-CT; AH Plus; flowable MTA sealer; interface porosity; mineral trioxide aggregate; Thermafil; MINERAL TRIOXIDE AGGREGATE; CALCIUM-SILICATE CEMENTS; TERM SEALING ABILITY; GUTTA-PERCHA; COMPUTED-TOMOGRAPHY; CANAL PREPARATION; LONG-TERM; PORTLAND-CEMENT; OBTURATION; DENTIN;
D O I
10.1111/j.1365-2591.2012.02124.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Gandolfi MG, Parrilli AP, Fini M, Prati C, Dummer PMH. 3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer. International Endodontic Journal, 46, 253-263, 2013. Aim To investigate nondestructively the percentage of 3D voids and marginal gaps in a pre-defined interface volume of interest (VOI) within root fillings produced by Thermafil Obturators with either a hydrophobic epoxy-resin-based sealer (AH Plus) or a hydrophilic flowable calcium-silicate sealer [mineral trioxide aggregate (MTA) Flow]. Methodology Sixteen single root canals from extracted premolar teeth were prepared with ProTaper rotary instruments, randomly allocated into two groups (n=8) and filled with size 30 Thermafil Obturators in association with AH Plus or MTA Flow sealers. The filled roots were stored at 37 degrees C in 5mL of Hank's balanced salt solution (HBSS) used to represent body fluids and scanned after 7days and 6months using a high-resolution micro-CT. From each root, images of 3000 sections were analysed in 3D and binarized using a high-resolution micro-CT (4- resolution). The 3D distribution of voids (porosity and marginal gaps) at the gutta-percha-sealer-dentine interface was detected through a threshold grey level and expressed as percentage of the 40--thick pre-defined interface VOI (20 of interface dentine and 20 of gutta-percha/sealer). A method of analysis based on the root canal segmentation was used, and coronal, middle and apical thirds considered separately. The percentage of 3D void volume was compared statistically using one-way anova (significance for P<0.05). Environmental Scanning Electron Microscope with Energy Dispersive X-ray (ESEM-EDX) analysis was performed on the surface of both sealers after soaking in HBSS. Results Micro-CT detected gaps at the dentine-sealer interface in both groups. Void volumes wider than 10.21m3 with 1.35mdiameter were detected. Cul-de-sac-type voids (blind pores) and through-and-through voids (continuous pores) were discriminated. The apical thirds had a significantly lower 3D void volume (P<0.05) than the middle and coronal thirds. The 3D void volume reduced significantly (P<0.05) over time. ESEM-EDX analysis revealed that MTA Flow sealer created a dense apatite layer after 7days of immersion in HBSS, whilst only sparse calcium phosphate deposits were detected on AH Plus even after 28days. Conclusions Micro-CT proved to be a powerful nondestructive 3D analysis tool for visualizing the porous internal microstructure of dental/endodontic materials at the interface with dentine. The proportion of voids was least in the apical third of root canals. Voids reduced over time in the presence of simulated body fluid.
引用
收藏
页码:253 / 263
页数:11
相关论文
共 50 条
  • [41] Local plate/rod descriptors of 3D trabecular bone micro-CT images from medial axis topologic analysis
    Peyrin, Francoise
    Attali, Dominique
    Chappard, Christine
    Benhamou, Claude Laurent
    MEDICAL PHYSICS, 2010, 37 (08) : 4364 - 4376
  • [42] A 3D analysis of mechanically stressed dentin-adhesive-composite interfaces using X-ray micro-CT
    De Santis, R
    Mollica, F
    Prisco, D
    Rengo, S
    Ambrosio, L
    Nicolais, L
    BIOMATERIALS, 2005, 26 (03) : 257 - 270
  • [43] Character analysis and descriptions of Eocene sphodrine fossils (Coleoptera, Carabidae) using light microscopy, micro-CT scanning, and 3D imaging
    Schmidt, Joachim
    Scholz, Stephan
    Will, Kipling
    DEUTSCHE ENTOMOLOGISCHE ZEITSCHRIFT, 2022, 69 (01) : 19 - 44
  • [44] 3D–2D microleakage assessment of preheated bulk-fill composite resin applied with different parameters: a micro-CT analysis
    Dilber Bilgili Can
    Merve Özarslan
    Odontology, 2023, 111 : 942 - 952
  • [45] 3D Morphological Analysis of Age and Sex-Related Changes in Human Cortical Bone Remodeling Spaces Using Micro-CT
    Wei, Xuan
    Loundagin, Lindsay
    Cooper, David Michael Lane
    JOURNAL OF BONE AND MINERAL RESEARCH, 2024, 39 : 126 - 126
  • [46] 3D X-ray Micro-CT Analysis of Rebar Corrosion in Reinforced Concrete Subjected to a Chloride-Induced Environment
    Skarzynski, Lukasz
    Kibort, Katarzyna
    Malachowska, Aleksandra
    MOLECULES, 2022, 27 (01):
  • [47] Sandstone 3D compositional microstructure analysis with synchrotron-based multi-energy x-ray micro-CT
    Kong, Huihua
    Li, Ruru
    Yang, Yushuang
    Bai, Bin
    Wang, Haipeng
    MATERIALS RESEARCH EXPRESS, 2020, 7 (06)
  • [48] Local mapping of root orientation traits by X-ray micro-CT and 3d image analysis: A study case on carrot seedlings grown in simulated vs real weightlessness
    Gargiulo, L.
    Mele, G.
    Izzo, L. G.
    Romano, L. E.
    Aronne, G.
    PLANT METHODS, 2024, 20 (01)
  • [49] 3D visualization and morphometric analysis of spinal motion segments and vascular networks: A synchrotron radiation-based micro-CT study in mice
    Guo, Zhu
    Li, Chengjun
    Cao, Yong
    Jiang, Liyuan
    Zhang, Yi
    Li, Ping
    Zhou, Yongchun
    Duan, Chunyue
    Hu, Jianzhong
    Lu, Hongbin
    JOURNAL OF ANATOMY, 2022, 240 (02) : 268 - 278
  • [50] Analysis of the mouse/rat pulmonary arterial tree branching geometry using three dimensional (3D) X-ray micro-CT
    Pettersen, M
    Ritman, E
    EUROPEAN HEART JOURNAL, 2000, 21 : 313 - 313