3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer

被引:85
|
作者
Gandolfi, M. G. [1 ]
Parrilli, A. P. [2 ]
Fini, M. [2 ]
Prati, C. [1 ,3 ]
Dummer, P. M. H. [4 ]
机构
[1] Univ Bologna, Dept Odontostomatol Sci, Lab Biomat & Oral Pathol, Bologna, Italy
[2] Rizzoli Orthopaed Inst, Lab Preclin & Surg Studies, Bologna, Italy
[3] Univ Bologna, Dept Odontostomatol Sci, Endodont Clin Sect, Bologna, Italy
[4] Cardiff Univ, Sch Dent, Cardiff CF10 3AX, S Glam, Wales
关键词
3D micro-CT; AH Plus; flowable MTA sealer; interface porosity; mineral trioxide aggregate; Thermafil; MINERAL TRIOXIDE AGGREGATE; CALCIUM-SILICATE CEMENTS; TERM SEALING ABILITY; GUTTA-PERCHA; COMPUTED-TOMOGRAPHY; CANAL PREPARATION; LONG-TERM; PORTLAND-CEMENT; OBTURATION; DENTIN;
D O I
10.1111/j.1365-2591.2012.02124.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Gandolfi MG, Parrilli AP, Fini M, Prati C, Dummer PMH. 3D micro-CT analysis of the interface voids associated with Thermafil root fillings used with AH Plus or a flowable MTA sealer. International Endodontic Journal, 46, 253-263, 2013. Aim To investigate nondestructively the percentage of 3D voids and marginal gaps in a pre-defined interface volume of interest (VOI) within root fillings produced by Thermafil Obturators with either a hydrophobic epoxy-resin-based sealer (AH Plus) or a hydrophilic flowable calcium-silicate sealer [mineral trioxide aggregate (MTA) Flow]. Methodology Sixteen single root canals from extracted premolar teeth were prepared with ProTaper rotary instruments, randomly allocated into two groups (n=8) and filled with size 30 Thermafil Obturators in association with AH Plus or MTA Flow sealers. The filled roots were stored at 37 degrees C in 5mL of Hank's balanced salt solution (HBSS) used to represent body fluids and scanned after 7days and 6months using a high-resolution micro-CT. From each root, images of 3000 sections were analysed in 3D and binarized using a high-resolution micro-CT (4- resolution). The 3D distribution of voids (porosity and marginal gaps) at the gutta-percha-sealer-dentine interface was detected through a threshold grey level and expressed as percentage of the 40--thick pre-defined interface VOI (20 of interface dentine and 20 of gutta-percha/sealer). A method of analysis based on the root canal segmentation was used, and coronal, middle and apical thirds considered separately. The percentage of 3D void volume was compared statistically using one-way anova (significance for P<0.05). Environmental Scanning Electron Microscope with Energy Dispersive X-ray (ESEM-EDX) analysis was performed on the surface of both sealers after soaking in HBSS. Results Micro-CT detected gaps at the dentine-sealer interface in both groups. Void volumes wider than 10.21m3 with 1.35mdiameter were detected. Cul-de-sac-type voids (blind pores) and through-and-through voids (continuous pores) were discriminated. The apical thirds had a significantly lower 3D void volume (P<0.05) than the middle and coronal thirds. The 3D void volume reduced significantly (P<0.05) over time. ESEM-EDX analysis revealed that MTA Flow sealer created a dense apatite layer after 7days of immersion in HBSS, whilst only sparse calcium phosphate deposits were detected on AH Plus even after 28days. Conclusions Micro-CT proved to be a powerful nondestructive 3D analysis tool for visualizing the porous internal microstructure of dental/endodontic materials at the interface with dentine. The proportion of voids was least in the apical third of root canals. Voids reduced over time in the presence of simulated body fluid.
引用
收藏
页码:253 / 263
页数:11
相关论文
共 50 条
  • [1] 3D micro-CT analysis of cancellous bone architecture
    Rossi, M
    Casali, F
    Romani, D
    Carabini, ML
    DEVELOPMENTS IN X-RAY TOMOGRAPHY III, 2002, 4503 : 349 - 358
  • [2] 3D analysis of the trabecular bone using micro-CT
    Moon, HS
    Shim, WH
    Lim, BJ
    Kim, KD
    Kim, HJ
    Chung, MK
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B323 - B323
  • [3] Micro-CT analysis of 3D printed provisional crowns fitting
    Alsubaiy, Ebrahim Fihaid
    TECHNOLOGY AND HEALTH CARE, 2023, 31 (01) : 259 - 268
  • [4] Trans-scale analysis of 3D braided composites with voids based on micro-CT imaging and unsupervised machine learning
    Song, Xinyi
    Zhou, Jin
    Zhang, Di
    Zhang, Shenghao
    Li, Pei
    Bai, Longteng
    Yang, Xiaohui
    Du, Feiping
    Wang, Jun
    Chen, Xuefeng
    Guan, Zhongwei
    Cantwell, Wesley J.
    COMPOSITES SCIENCE AND TECHNOLOGY, 2024, 249
  • [5] Present and future in the use of micro-CT scanner 3D analysis for the study of dental and root canal morphology
    Grande, Nicola M.
    Plotino, Gianluca
    Gambarini, Gianluca
    Testarelli, Luca
    D'Ambrosio, Ferdinando
    Pecci, Raffaella
    Bedini, Rossella
    ANNALI DELL ISTITUTO SUPERIORE DI SANITA, 2012, 48 (01): : 26 - 34
  • [6] Extraction and analysis of large vascular networks in 3D micro-CT images
    Wan, SY
    Ritman, EL
    Higgins, WE
    MEDICAL IMAGING 1999: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 1999, 3660 : 322 - 334
  • [7] 3D analyses of interface voids in root canals filled with different sealer materials in combination with warm gutta-percha technique
    M. Wolf
    K. Küpper
    S. Reimann
    C. Bourauel
    M. Frentzen
    Clinical Oral Investigations, 2014, 18 : 155 - 161
  • [8] 3D analyses of interface voids in root canals filled with different sealer materials in combination with warm gutta-percha technique
    Wolf, M.
    Kuepper, K.
    Reimann, S.
    Bourauel, C.
    Frentzen, M.
    CLINICAL ORAL INVESTIGATIONS, 2014, 18 (01) : 155 - 161
  • [9] Comparative Micro-CT Evaluation of Dentinal Tubule Penetration of BIO-C and AH Plus Jet Root Canal Sealer Using Three Intra-Canal Activation Techniques
    Vivek, K.
    Sreedhar, Sreeja
    Nair, Siddharth V.
    Sreelekshmi, V.
    Jitha, J.
    Viswanadhan, Anitha
    Athira, P. M.
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 5) : S4568 - S4571
  • [10] Accurate segmentation for quantitative analysis of vascular trees in 3D micro-CT images
    Riedel, CH
    Chuah, SC
    Zamir, M
    Ritman, EL
    MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 : 256 - 265