Patient-related factors determining geometry of intracavitary applicators and pelvic dose distribution during cervical cancer brachytherapy

被引:8
|
作者
SenkusKonefka, E
Kobierska, A
Jassem, J
Badzio, A
机构
[1] Dept. of Oncology and Radiotherapy, Med. University of Gdańsk, Gdańs
[2] Dept. of Oncology and Radiotherapy, Med. University of Gdańsk, 80-211 Gdansk
关键词
cervical cancer; brachytherapy; dose distribution;
D O I
10.1016/S0360-3016(96)00561-5
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to assess retrospectively the influence of the size of cervical cancer brachytherapy applicators (avoids and uterine tandems) on pelvic dose distribution and to analyze the impact of various patient- and disease-related factors on applicators' geometry and on dose distribution in particular applications. Methods and Materials: The subject of this study were 356 cervical cancer patients treated with Selectron LDR as a part of their radical radiotherapy. Analyzed factors included patient age, weight, number of vaginal deliveries, and disease stage. Results: The use of larger vaginal applicators resulted in lower bladder and rectum doses and in higher point B doses (all p < 0.0001); longer uterine tandems produced lower rectum doses and higher point B doses (both p < 0.0001). Increasing patient age and disease stage resulted in a decreased frequency of use of large ovoids (both p < 0.0001) and of long tandems (age: p = 0.0069, stage: p = 0.004). As a result, higher doses to bladder (age: p < 0.0001, stage: p = 0.017) and rectum (age: p = 0.037, stage: p = 0.011) were observed. Increasing age also resulted in lower point B doses (p < 0.0001). Increasing patient weight correlated with less frequent use of long tandems (p = 0.0015) and with higher bladder doses (p = 0.04). Higher number of vaginal deliveries was related to the increase in the use of long tandems (p = 0.002); in patients who had had at least one vaginal delivery, paint B doses were significantly higher (p = 0.0059). In multivariate analysis avoid size and uterine tandem length were dependent on patient age (respectively: p < 0.001 and p = 0.001), disease stage (respectively: p = 0.003 and p = 0.008) and on the number of vaginal deliveries (respectively: p = 0.07 and p = 0.008). Doses to critical organs and to points B were dependent on patient age (respectively: p < 0.001,p = 0.011, and p < 0.001) and on disease stage (respectively: p < 0.001, p = 0.004, and p = 0.048). Conclusion: The results of this study allow for identification of some patient- and disease-related factors influencing pelvic dose distribution in cervical cancer brachytherapy. This potentially may enable optimization of the dose distribution in particular clinical situations. (C) 1997 Elsevier Science Inc.
引用
下载
收藏
页码:531 / 536
页数:6
相关论文
共 50 条
  • [1] Dosimetric Modeling of Intracavitary versus Combined Intracavitary/Interstitial Applicators During High Dose Rate Brachytherapy for Cervical Cancer
    Bodine, T.
    Soultan, D.
    Badkul, R. K.
    Hoover, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : E475 - E476
  • [2] Impact of brachytherapy applicators geometry on dose distribution in gynaecological cancer
    Rehman, Ateeque Ur
    Buzdar, Saeed Ahmad
    Hassan, Muhammad
    Gadi, Asghar
    Khan, Muhammad Afzal
    Anjum, Muhammad Naeem
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2016, 66 (12) : 1566 - 1570
  • [3] Assessing dose contribution to pelvic lymph nodes in intracavitary brachytherapy for cervical cancer
    Chua, Gail Wan Ying
    Foo, Yong Wee
    Toy, Guan Heng
    Tan, David Boon Horn
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (04) : 345 - 353
  • [4] Assessing dose contribution to pelvic lymph nodes in intracavitary brachytherapy for cervical cancer
    Chua, G. W. Y.
    Tan, D. B. H.
    Tay, G. H.
    Foo, Y. W.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S13 - S14
  • [5] INFLUENCE OF APPLICATORS DESIGN ON THE QUALITY OF HIGH DOSE RATE INTRACAVITARY BRACHYTHERAPY INSERTIONS FOR WOMEN WITH CERVICAL CANCER
    De Melo, M. D.
    Balloni, H.
    Novaes, P. E. R. S.
    Castro, D. G.
    Teixeira, G. N.
    Fogaroli, R. C.
    Maia, M. A. C.
    Pellizon, A. C.
    Hanriot, R.
    Salvajoli, J. V.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88
  • [6] Comparison of intracavitary brachytherapy and stereotactic body radiotherapy dose distribution for cervical cancer
    Cengiz, Mustafa
    Dogan, Ali
    Ozyigit, Gokhan
    Erturk, Ertugrul
    Yildiz, Ferah
    Selek, Ugur
    Ulger, Sukran
    Colak, Fatma
    Zorlu, Faruk
    BRACHYTHERAPY, 2012, 11 (02) : 125 - 129
  • [7] Intracavitary Versus Combined Intracavitary/Interstitial Applicators During High Dose Rate (HDR) Image Guided Adaptive Brachytherapy (IGABT) for Cervical Cancer: A Dosimetric Comparison
    Soultan, D.
    Bodine, T.
    Hoover, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E801 - E801
  • [8] Factors affecting the dosimetry of high-dose rate intracavitary brachytherapy in cervical cancer
    Mahapatra, Bikash Ranjan
    Barik, Sandip Kumar
    Das, Deepak Kumar
    Das Majumdar, Saroj Kumar
    Parida, Dillip Kumar
    Ramasubbu, Mathan Kumar
    Badajena, Avinash
    Barik, Bijay Kumar
    Mishra, Minakshi
    Pattanaik, Ashutosh
    Kanungo, Satyabrata
    Muraleedharan, Anupam
    Ahmed, Sk Soel
    Mukherjee, Priyanka
    Abdulla, Shaha Sheik
    Mahajan, Ankur
    Sarkar, Arnab
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2024, 23
  • [9] Dose to pelvic lymph nodes in locally advanced cervical cancer during high-dose-rate brachytherapy with tandem-ring applicators
    Moghani, Mona Malekzadeh
    Siavashpour, Zahra
    Ogorodniitchouk, Oleksander
    Moreno-Acosta, Pablo
    Plattard, Delphine
    Vallard, Alexis
    Sotton, Sandrine
    Bouleftour, Wafa
    Langrand-Escure, Julien
    Magne, Nicolas
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2022, 14 (02) : 183 - 188
  • [10] Study of factors influencing dose distribution of brachytherapy in cervical cancer
    刘孜
    高莹
    罗伟
    王国庆
    王蕊花
    郑伟
    刘锐
    Journal of Pharmaceutical Analysis, 2008, (02) : 125 - 127